How do tower fabricators answer an OEM's enquiry?
A tower order is serial work. The turbine maker, the OEM, owns the design and issues the same package to each approved fabricator: drawings for every section and a set of specifications that say how to build them. The fabricator is asked for a price per tower and for a statement of where its shop cannot follow the package as written.
| Part of the package | What it covers | Point to settle before the offer |
|---|---|---|
| Fabrication specification and drawings | Shell courses, flanges, door frame, weld details and the standards that govern | Which document wins when the drawing and the specification disagree? |
| Plate specification | Steel grade, delivery condition, testing, certificate type and sometimes approved mills | Can your plate supplier meet it, and is the mill on the OEM's list? |
| Flange specification | Forged ring flanges: material, testing, machining and certificate type | Is the forge approved by the OEM, and who buys the flanges, you or the OEM? |
| Welding requirements | Processes allowed, procedure and welder qualification, and any production tests | Do your procedures cover the thickest shell-to-flange joint in the tower? |
| NDE requirements | Methods and extent for longitudinal seams, circumferential seams and attachments, and the personnel scheme | Is the extent for each weld category clear from the package? |
| Tolerances | Shell roundness and straightness, section length, and flange flatness and tilt, named here without values | Can your measuring method and equipment show each one, at the stage the OEM wants it measured? |
| Surface treatment | Blast cleaning, the coating system inside and outside, inspection and repair | Is the named system and paint supplier one you are set up to apply? |
| Internals | Platforms, ladders, cable supports and brackets, and what is welded to the shell | Which internals are in your scope, and which welds to the shell need the OEM's approval? |
| Quality and documentation requirements | The inspection plan, hold points, audits by the OEM and the record set for each section | What goes in the dossier, in what format, and when is it due? |
General points about a steel enquiry, such as the execution class and certificate types, are on the steel fabricators page. What is particular here is that almost nothing is left to the fabricator's choice. The design has been analysed for fatigue by someone else. A change to a weld detail or a bracket position that looks harmless in the shop may not be harmless to that analysis, so it goes back to the OEM as a deviation request.
Which standards come up in tower fabrication?
| Standard | What it is | How it reaches the fabricator |
|---|---|---|
| EN 1090-2 | Technical requirements for the execution of steel structures | European OEM specifications commonly build on it and state the execution class |
| ISO 3834 | Quality requirements for fusion welding of metallic materials | The welding quality system the shop is expected to run and often to hold certification for |
| EN 10204 | Types of inspection document for metallic products | The specification states type 3.1 or 3.2 for plate and for flanges, and they are not always the same |
| ISO 12944 | Corrosion protection of steel structures by protective paint systems, in several parts including one for offshore structures | Called up for the coating system, or replaced by the OEM's own coating specification |
| IEC 61400 series | The international standards for wind energy generation systems, including design requirements for turbines, towers and foundations | Context only. The OEM designs to it. The fabricator sees its effect through the OEM's specification |
| DNV-ST-0126 | DNV's standard, Support structures for wind turbines | DNV describes it as a contractual reference for the design and construction of support structures. Some specifications name it |
| The OEM's specifications | The turbine maker's own documents for fabrication, welding, coating and quality | They govern. Where they are stricter than a standard, the stricter rule is the contract |
The turbine itself is usually covered by a type certificate, and the tower design is part of what was assessed. That is the reason an OEM controls its fabrication specification so closely. Welding codes from other families appear on some projects. For the American structural code, see AWS D1.1. These are paid documents and this page does not give their limits.
What goes in a tower fabricator's deviation list?
There are two kinds of deviation in tower work. The first is raised with the offer: a standing difference between the OEM's package and how your shop works. The second is raised during production against one section, often called a concession or a non-conformance request. Both need the OEM's written answer. Typical subjects are these.
- Plate supply: a mill that is not on the OEM's approved list, a different delivery condition, or a plate size that moves the position of a seam.
- Flanges: an alternative forge, a certificate type other than the one specified, or a machining sequence that differs from the specification.
- Welding: a process or consumable the specification does not list, or a joint preparation changed to suit your equipment.
- Seam layout: a different number of shell courses or a changed offset between longitudinal seams, which alters the weld map.
- NDE: a method substituted for the one named, or a different personnel certification scheme.
- Tolerances: the stage at which flange flatness is measured, or the measuring method, where yours differs from the OEM's.
- Coating: an equivalent paint system from another supplier, or application conditions your booth cannot hold all year.
- Internals: brackets welded where the drawing shows bolted or magnetic fixings, or the reverse.
- Records: your own report formats where the OEM issues templates, or a different dossier structure.
Write each row with the clause, your proposal and the reason. The technical deviation list guide shows the layout. The Deviation Register (beta) then keeps the OEM's answers in one list, which matters when the same answer has to hold for every section in a long series.
Which documents go with each tower section?
| Record | What it shows | Gap that holds a section |
|---|---|---|
| Plate certificates with traceability | Each shell course tied to a plate, a heat and a certificate of the type specified | A course whose plate number was not carried from the cutting record to the section's material list. See heat number traceability |
| Flange certificates | Material tests, any examination by the forge and the dimensional record for each flange, by serial number | A certificate of the wrong type, or one whose serial number is not the flange welded on |
| Weld map and welder records | Every longitudinal seam, circumferential seam and attachment weld, with its procedure, welder and date | Attachment welds for internals left off the map |
| NDE reports | Examination of each weld to the method and extent specified | A seam on the map with no ultrasonic report, or a repair with no later report |
| Heat treatment records | Post-weld heat treatment charts, only where the specification asks for it | Not applicable on most sections. A gap only when the clause exists and the chart does not |
| Dimensional report | Length, roundness and straightness of the section against the drawing tolerances | Readings taken before the last weld was made |
| Flange flatness report | Flatness and tilt of each flange after welding, with the method and instrument | A report with no instrument identity, or measured at a different stage from the one specified |
| Coating inspection records | Surface preparation, conditions, each coat applied and film thickness checks, inside and outside | A record for one coat of the system missing from the set |
| Section dossier | All of the above for one serial number, in the OEM's index order | A dossier assembled from the previous section's template with the old serial number left in |
The wind tower section ITP template sets out the inspection stages these records come from. Because every section has the same index, a gap tends to repeat. If the intermediate coat record is missing from one dossier, check the other sections coated in the same week.
How does OdysseyGPT help?
OdysseyGPT takes the OEM's requirements and your documents and reports where they differ, with the passage quoted from each. A quality engineer accepts or rejects every finding. It reads text and tables, so the weld map and the material list must be given as a list or spreadsheet. A drawing alone will not do.
| Your documents | Checked against | Tool | What is reported |
|---|---|---|---|
| Your quality plan and standard procedures | The OEM's fabrication, welding and coating specifications | Document Review | Requirements your documents meet, differ from or do not mention, as a draft deviation list |
| The OEM package on its own | Nothing else: it is read alone | Customer Specification Review (beta) | The requirements listed by type, with open items such as a specification named and not supplied |
| Your inspection and test plan | The OEM's quality requirements | ITP Validator (beta) | Missing stages, and hold or witness points entered at a lower level |
| Plate and flange certificates | The purchase requirements | Material Certificate Review (beta) | Wrong certificate type, wrong grade or condition, and required tests the certificate does not report |
| The section's material list and heat register | The certificates on file | Material Traceability Check (beta) | Heats with no certificate and certificates tied to no part |
| Welder qualifications and the weld log | Your welding procedures and their qualification records | Welding Qualification Review (beta) | Welds outside the qualified range and welders not qualified on the weld date |
| NDE reports and repair records | The weld map and the specified method for each weld | NDE Coverage Review (beta) | Welds with no report, a different method, short coverage or an unclosed repair |
| Inspection reports that name an instrument | The calibration certificates | Calibration Validity Check (beta) | Instruments with no certificate, or one that was out of date when the reading was taken |
| The section's document folder | The OEM's dossier index | MRB Readiness Check (beta) | Index lines with no document, old revisions and unapproved records |
| The compiled dossier | The weld map and ITP | MRB Traceability Verification (beta) | Broken links from weld to welder and procedure, and from shell course to heat and certificate |
No tool judges the numbers on a flatness, dimensional or coating report. The checks above confirm that those reports exist for the section, carry the right serial number and name an instrument that was in calibration. The MRB Compiler (beta) lays the approved documents out against the OEM's index for the final dossier.
What does a result look like for a tower section?
Everything in this example is invented: the section, the weld numbers, the flange serial number, the heat number, the instrument and the dates. No real project or supplier is behind it. It is here to show the form of the findings.
| ID | Finding | Why it was raised | Category | Severity | Confidence |
|---|---|---|---|---|---|
| F-MTR-01 | Top flange certificate is EN 10204 type 3.1 where type 3.2 is required | The flange specification asks for a type 3.2 inspection certificate for all ring flanges. The certificate for flange serial FL-2291 is headed 3.1 and carries no independent inspector's endorsement. | Certificate type | Critical | High |
| F-MTR-02 | Plate certificate does not report the through-thickness test the order requires | The plate purchase requirement lists a through-thickness tensile test for the shell course welded to the flange. The certificate for plate P-0417 shows tensile and impact results only. | Missing test | High | High |
| F-TRC-01 | Heat 73L208 on shell course 5 has no certificate in the set | The section material list records heat 73L208 for course 5. No plate certificate in the folder carries that heat number. | Unlinked heat | High | High |
| F-NDE-01 | Circumferential weld CW-06 has no ultrasonic report | The weld map lists CW-06 between courses 6 and 7. The specification requires ultrasonic examination of every circumferential seam. The reports cover CW-01 to CW-05 and CW-07. | Missing report | Critical | High |
| F-NDE-02 | Repair on longitudinal weld LW-03 was not examined again | Repair record R-014 for LW-03 is dated 2026-03-11. The only ultrasonic report that names LW-03 is dated 2026-03-09. | Unclosed repair | High | Medium |
| F-WLD-01 | Welder W-41 was not qualified for the process used on the door frame weld | The weld log records submerged arc welding by W-41 on DF-01. The welder's certificate on file covers a different process. | Welder qualification | Critical | High |
| F-ITP-01 | ITP shows flange flatness measurement after welding as a review point | The quality requirements make flange flatness measurement after welding a hold point for the purchaser's inspector. ITP line 14 marks it R. | Downgraded inspection point | Medium | High |
| F-CAL-01 | Film thickness gauge on the coating record was out of calibration on the date of use | Coating inspection record CIR-T2-03 names gauge DFT-07 on 2026-03-20. The calibration certificate for DFT-07 expired on 2026-02-28. | Expired at use | High | High |
| F-MRB-01 | No inspection record for the intermediate coat | The dossier index lists three coating inspection records for the outside surface: primer, intermediate coat and top coat. The folder holds records for the primer and the top coat. | Missing document | High | High |
Each finding opens to the document, the page or cell and the quoted text. Several of these would be settled by finding a misfiled report. One or two would hold the section. The engineer makes that call, and the list makes sure the question is asked before the OEM's inspector asks it.
Where OdysseyGPT falls short
- It does not read tower drawings or models. Seam numbers, course numbers and flange serial numbers have to come from a list.
- It does no structural or fatigue assessment and cannot say whether a deviation is acceptable to the tower design. That is the OEM's decision.
- It does not measure anything. It does not perform or assess a flange flatness survey, a dimensional survey or a film thickness check, and it does not judge the readings on those reports.
- It does not interpret ultrasonic data. It reads the result the technician wrote on the report.
- It does not certify a section, a weld, a welding quality system or a fabricator, and it has no role in turbine type certification.
- It is not production software. It does not plan the rolling line, track sections through the shop or manage plate stock.
- It checks against the documents you give it. If the OEM's coating specification is not uploaded, coating clauses cannot be checked.
- To judge it, take the dossier of a section that was held at final inspection and see whether the review finds the reason.
Which tools are available now
Document Review is generally available. Every other tool on this page is in beta, which means you request access and we onboard your team ourselves. See the inspection module, the handover module and OdysseyGPT for manufacturing.
Try it on your own documents
Free sample: a certificate check report
Send up to 20 material certificates and the PO. Get a certificate check report.