OdysseyGPT

Standards explainer

EN 1090 explained: execution classes, factory production control and CE marking of structural steelwork

A plain-English overview of EN 1090 for contracts and quality engineers at steel fabricators, ending with a checklist for a tender that calls up the standard.

By Ademola Afolabi, Founder, New Odyssey Ltd · Last reviewed:

The short answer

EN 1090 is the European standard series for making steel and aluminium structures. Part 1 sets how a fabricator's components are assessed so they can carry CE marking. Part 2 gives the technical rules for steel, scaled by four execution classes, EXC1 to EXC4. Part 3 does the same for aluminium.

Key Takeaways

  • EN 1090-1 is about conformity assessment and marking. EN 1090-2 is about how the steelwork is made.
  • The designer specifies the execution class. A fabricator can only take work up to the class on its certificate.
  • A notified or approved body certifies the fabricator's factory production control. The fabricator issues the declaration of performance.
  • In Great Britain both UKCA and CE marking are currently accepted. Check gov.uk for the latest position.

Free sample: a certificate check report. Send up to 20 material certificates and the PO. Get a certificate check report. Get the free result

What is EN 1090?

EN 1090, Execution of steel structures and aluminium structures, is a series of European standards. "Execution" means everything done to turn a design into a finished structure: buying materials, cutting, welding, bolting, surface treatment, erection and inspection. A fabricator mostly meets three parts.

The parts of EN 1090 a fabricator meets most often (own summary)
PartSubjectWhat it means for a fabricator
EN 1090-1Requirements for conformity assessment of structural componentsThe route to a declaration of performance and CE marking. It requires a certified factory production control system
EN 1090-2Technical requirements for steel structuresThe rules the shop works to: materials, cutting, welding, bolting, tolerances, surface treatment, inspection and documentation
EN 1090-3Technical requirements for aluminium structuresThe equivalent of part 2 for aluminium work

Part 1 leans on part 2. A fabricator shows that its components perform as declared by making them to the technical rules of part 2, under a controlled system. National standards bodies publish the series under their own prefix, such as BS EN 1090 in the UK. The parts are paid documents with different edition dates. Use the editions your contract names.

Execution classes EXC1 to EXC4

EN 1090-2 does not apply one level of control to every structure. It defines four execution classes, EXC1 to EXC4. The requirements become stricter as the number rises. The class changes practical things: how much welds are inspected, how far materials are traced, what welding quality system is needed and how much is documented.

  • The designer or structural engineer specifies the class, based on the consequences of failure and how the structure is loaded and made. The fabricator does not choose it.
  • A class can apply to the whole structure, and a different class can be given to particular components or details.
  • UK industry guidance says EXC2 suits most buildings, and warns against adding higher-class requirements to an EXC2 job without reason.
  • One certification body gives agricultural buildings as an example of EXC1, residential and commercial buildings for EXC2, bridges for EXC3 and special structures such as long-span bridges for EXC4. These are illustrations, not rules.
  • A fabricator's certificate states the highest class it covers. A shop certified for EXC3 can take EXC1, EXC2 and EXC3 work. A shop certified for EXC2 cannot take EXC3 work.

If an enquiry calls up EN 1090-2 and gives no execution class, raise a clarification. Do not price on a guess. The selection method and the requirements for each class are in the standard, and this page does not reproduce them.

Welding under EN 1090-2

Welding is treated as a process that needs its own management system. Fabricators run a welding quality system to the relevant part of ISO 3834, and the part depends on the execution class. From EXC2 upwards the welding is controlled by a responsible welding coordinator, whose required technical knowledge also depends on the class, the steels and the thicknesses.

The supporting standards are from the ISO family and differ from the American ones. Welding procedures are written and qualified to the ISO 15609 and ISO 15614 series, welders are qualified to ISO 9606-1, and NDT personnel to ISO 9712. Every weld is visually inspected. Further NDT depends on the execution class and the type of joint. For how this compares with the American approach, see AWS D1.1.

Factory production control and the notified body

Factory production control, or FPC, is the fabricator's own documented, permanent, internal control of production. Under EN 1090-1 it covers how the shop controls design input where it does design, purchasing, materials, welding, equipment, inspection and non-conforming work.

Who does what for structural steel components under the Construction Products Regulation (own summary)
PartyTask
The fabricatorRuns the FPC system, carries out the initial assessment of its products, tests in line with its own plan, appoints a responsible welding coordinator, and issues the declaration of performance
The notified body (EU) or approved body (UK)Inspects the plant and the FPC system at the start, then carries out continuing surveillance. It issues an FPC certificate and a welding certificate that states the execution class covered
The customer or main contractorChecks that the certificates are in date, name the right body and cover the project's execution class and materials

The body certifies the system, not each beam. It does not inspect your project and it does not sign the declaration. That responsibility stays with the fabricator.

Declaration of performance and CE marking

EN 1090-1 is a harmonised standard under the EU Construction Products Regulation. Where a construction product is covered by a harmonised standard, the manufacturer draws up a declaration of performance when placing it on the market. CE marking is affixed only to products that have one. By affixing it, the manufacturer takes responsibility for the product matching the declared performance. CE marking has been mandatory for fabricated structural steelwork in the EU since 1 July 2014.

The declaration identifies the product type and its intended use, the manufacturer, the assessment system, the notified body and the declared performance for the essential characteristics. For a customer, the useful checks are whether it names the project's execution class and whether its materials cover what is on the drawings.

The regulation is changing

A revised Construction Products Regulation, Regulation (EU) 2024/3110, entered into force on 7 January 2025, and most of it applies from 8 January 2026. The Commission says products covered by a standard cited under the 2011 regulation generally stay under the 2011 rules until a new harmonised standard for that product family is cited, with a transition period of at least a year. When we checked in November 2026 we found no revised EN 1090-1 cited under the new regulation. Check the Commission's pages and your notified body before you rely on this.

The UK position: UKCA and CE

BS EN 1090-1 is a UK designated standard as well as a European harmonised one. Since 1 January 2021, Great Britain has had its own construction products regime with the UKCA mark, and UK notified bodies became UK approved bodies.

  • The government's guidance, last updated on 21 May 2025 when we read it, says CE marking continues to be recognised for construction products in Great Britain, following a ministerial statement of 2 September 2024. Its longer-term future depends on wider reform of the construction products regime.
  • UKCA marking is available and needs a UK approved body. CE marking needs a body recognised in the EU.
  • A fabricator that applies both marks needs declarations of performance that meet both the GB and the EU requirements.
  • Northern Ireland follows different rules. Products there carry CE marking, or CE with the UK(NI) indication when a UK body did the assessment. UKCA alone is not valid there.

Some certification bodies' web pages still describe an end date for CE recognition that the government later withdrew. Treat the gov.uk guidance as the reference and read it again before each tender, because this area has changed several times.

What to check in a tender that calls up EN 1090

Tender checklist for work specified to EN 1090
CheckWhere to lookWhy it matters
Execution class, for the structure and for any special componentsFabrication specification and drawing notesIt sets inspection, traceability and welding control. Missing means a clarification
Your certificate against the class and materialsYour FPC and welding certificatesYou cannot declare performance outside their scope
Edition of each part namedList of standardsEditions differ, and the contract edition governs
Marking required: CE, UKCA or bothCommercial and quality sectionsIt decides which body's certificate and which declaration you need
Options and additions the specifier has chosenProject specificationEN 1090-2 leaves many choices to the specification. Each is a possible cost
Traceability levelFabrication specificationHigher classes and some customers want pieces tied to inspection documents
Inspection document type for steel and boltsMaterial sectionSee EN 10204 3.1 vs 3.2
NDT beyond the standardWelding and NDE specificationExtra extent or methods need pricing and a named personnel scheme
Tolerances beyond the standard onesFabrication specification and drawingsTighter limits affect fit-up, trial assembly and survey
Corrosion protectionCoating or galvanising specificationThe system, the inspection and who repairs damage after erection
Subcontracted workYour own planCoating, galvanising or NDT done by others still sits under your FPC
Records to hand overDocumentation requirementsCertificates, declaration of performance, welding and inspection records

The Customer Specification Review (beta) lists the requirements in a specification package and marks the ones that are unclear or missing, such as an execution class that is never stated. Document Review compares the package with your own procedures and quotes both. Neither assesses your FPC system or tells you which execution class a structure should have. That is the designer's decision and the certification body's assessment.

Try it on your own documents

Free sample: a certificate check report

Send up to 20 material certificates and the PO. Get a certificate check report.

Get the free result

Frequently asked questions

What is EN 1090?

The European standard series for the execution of steel and aluminium structures. Part 1 covers conformity assessment and CE marking of structural components, part 2 the technical requirements for steel, and part 3 the technical requirements for aluminium.

What is the difference between EN 1090-1 and EN 1090-2?

Part 1 says how a fabricator shows that its components conform, which leads to a declaration of performance and CE marking. Part 2 says how steelwork is to be made and inspected. A fabricator meets part 1 by working to part 2 under factory production control.

What are the EN 1090 execution classes?

Four classes, EXC1 to EXC4, with stricter requirements as the number rises. The designer specifies the class from the consequences of failure and the type of structure. UK guidance says EXC2 suits most buildings.

Is UKCA or CE marking needed for structural steel in Great Britain?

When we checked gov.uk in November 2026, both were accepted: UKCA through a UK approved body, or CE through an EU-recognised body. The position has changed before, so read the current guidance.

Does the notified body inspect each project?

No. It inspects the fabricator's plant and factory production control system, then carries out surveillance. The fabricator is responsible for each project and for the declaration of performance.

References

UKCA marking of fabricated structural steelwork

SteelConstruction.info (BCSA and SCI)

Parts 1 and 2, execution classes, system 2+ tasks, certificates, declaration of performance, Northern Ireland. Read 15 Nov 2026.

Visit source

Welding

SteelConstruction.info (BCSA and SCI)

Welding coordination, procedure and welder qualification standards, and inspection under BS EN 1090-2.

Visit source

CE marking

SteelConstruction.info (BCSA and SCI)

Dates on which CE marking became mandatory.

Visit source

This way to CE marking

New Steel Construction (BCSA)

Execution classes, the welding quality system and the responsible welding coordinator. An older article; dates in it are out of date.

Visit source

Regulation (EU) No 305/2011 (Construction Products Regulation)

EUR-Lex

Definition of factory production control; declaration of performance and CE marking articles.

Visit source

CPR 2024 revision

European Commission

Dates and transition for Regulation (EU) 2024/3110. Read 15 Nov 2026.

Visit source

Construction Products Regulation in Great Britain

GOV.UK

UKCA and CE marking in Great Britain. Page last updated 21 May 2025 when read on 15 Nov 2026.

Visit source

UKCA marking for structural steel

BM TRADA

Execution class examples and the responsible welding coordinator. Its statement on an end date for CE recognition is older than the gov.uk guidance.

Visit source

Related Pages