Pharmaceutical and bioprocess equipment manufacturers

Pharmaceutical equipment manufacturers: check every URS requirement against your documents

For the bid, project and quality engineers at makers of bioreactors, process vessels, skids, filling lines and CIP/SIP systems who answer a customer's User Requirement Specification and then deliver FAT, SAT and a turnover package.

By Ademola Afolabi, Founder, New Odyssey Ltd · Last reviewed:

The short answer

Pharmaceutical and bioprocess equipment manufacturers answer a tender by checking the customer's User Requirement Specification (URS) line by line against their own design, datasheets and standard documents, then listing every deviation. After award they deliver FAT and SAT documents and a turnover package. OdysseyGPT drafts the URS compliance matrix with a source quote for each requirement.

Key Takeaways

  • The URS is the customer's reference for the whole qualification, so every line you accept will be tested later.
  • URS packages call up ASME BPE, GAMP 5, EU GMP Annex 15, cGMP rules and material certificate types.
  • Deviations often sit in surface finish, weld documentation, software documents, test scope and document timing.
  • The customer qualifies the equipment. You supply the documents and tests that qualification relies on.
  • OdysseyGPT checks documents against the URS and quotes its sources. It does not qualify or validate anything.

See how OdysseyGPT reviews a tender. Tell us how your team reviews tenders today. We can walk through an example together. Book a call

How do pharmaceutical equipment manufacturers answer a URS?

An enquiry for a bioreactor, process vessel, skid, filling line or CIP/SIP system usually centres on a User Requirement Specification (URS). The URS lists numbered requirements for the process, materials, cleaning and sterilisation, automation, documentation and testing. Around it sit the customer's engineering standards, a supplier quality or documentation specification, the commercial terms and the standards and guides those documents call up.

The maker checks each numbered line against its own design, datasheets, functional specification and standard quality documents. It returns a URS response, often called a URS compliance matrix or traceability matrix, with a status and a comment for each line, and a list of deviations and clarifications. A blank format is in the free URS response matrix template.

The response matters more here than in most sectors. Under EU GMP Annex 15, the customer checks the URS during design qualification and keeps it as a point of reference through the validation life cycle. A line marked "complies" at bid stage is therefore likely to come back as a test or a document check at FAT, SAT or qualification.

Which standards and guides come up in a URS?

Documents a URS commonly calls up (own summary; read the edition your contract names)
DocumentWhat it coversTypical deviation source
ASME BPEDesign, materials, fabrication, inspection, testing and certification of bioprocessing equipment with hygienic requirementsSurface finish designation, weld acceptance and examination, drainability, fittings and component certification
GAMP 5ISPE's risk-based guide to computerised systems in GxP environments. A guide, not a regulationSoftware category, the specifications you supply, supplier testing and how much the customer can reuse
EU GMP Annex 15Qualification and validation: URS, design qualification, FAT and SAT, then IQ, OQ and PQFAT scope, which FAT tests the customer wants to reuse at site, and protocol formats
EU GMP Annex 11Computerised systems used in GMP activities, including requirements and supplier assessmentAudit trail, access control, supplier audit and life cycle documents
21 CFR 211, Subpart D (US cGMP)Equipment design, size and location, construction, cleaning and maintenance, and automatic and electronic equipmentProduct-contact materials, lubricant and coolant contact, cleanability and calibration
EN 10204Types of inspection document for metallic products. URSs usually ask for type 3.1 on product-contact partsWhich parts need a 3.1 certificate, and whether bought-in components can supply one
Pressure equipment code or directiveThe pressure design code the contract names, such as ASME Section VIII or the EU Pressure Equipment DirectiveCode edition, conformity route, inspection body and stamping or marking
Customer standardsThe drug manufacturer's own engineering, automation and documentation standardsApproved component lists, document formats, language and review times

At a high level, the US rule in 21 CFR 211.65 says surfaces that touch components, in-process materials or drug products must not be reactive, additive or absorptive in a way that alters the product beyond its established requirements. 21 CFR 211.63 asks for equipment of appropriate design and adequate size, located so it can be operated, cleaned and maintained. These duties fall on the drug manufacturer. The URS is how they reach you.

Surface finish and weld documentation

Two topics produce a large share of the deviations in this sector. The first is surface finish. A URS may give a roughness limit as a number, an ASME BPE surface finish designation, or both, and may add electropolishing and passivation. Check that the number and the designation agree, which surfaces they apply to, and how the finish is measured and reported.

The second is weld documentation for product-contact welds. URSs commonly ask for a weld map and weld log, welder and welding operator qualifications, weld procedures, material certificates linked to heat numbers, visual or borescope examination records and passivation records. The share of welds to be examined is often higher than a maker's standard practice. That is a cost, so it belongs on the deviation list or in the price.

What goes in the deviation list or URS response?

Each row of the response carries the URS number, the requirement, what you offer, a status and a comment. Where you do not comply, the row also needs a justification and, if you can give one, the cost or time to comply. The technical deviation list guide sets out the columns and the wording.

  • Materials and certificates: grade of product-contact parts, elastomer and polymer compliance statements, and which parts carry an EN 10204 3.1 certificate.
  • Surface finish: roughness limit, electropolish, passivation and the measurement report.
  • Welding: orbital or manual welds, examination extent, weld log format and acceptance criteria.
  • Cleanability: drainability, slopes, dead legs, spray device coverage testing and who performs it.
  • Automation: software category, the specifications supplied, audit trail, access control and the customer's standard libraries.
  • Testing: FAT and SAT scope, test media, who writes the protocols and how long the customer has to review them.
  • Documents: the turnover package index, formats, language, number of review rounds and delivery dates.
  • Qualification support: whether you supply IQ and OQ protocols, execute them, or only provide supporting documents.

Say what you support, not what you qualify

The drug manufacturer is responsible for qualification under GMP. A response that says "supplier will qualify the equipment" promises something you cannot give. State the documents and tests you supply, and which protocols you will write or execute under the customer's approval.

Which documents come after award?

Typical post-award documents for process equipment (own summary; the contract and URS decide)
DocumentWhat it is for
Functional and design specificationsShow how the design meets the URS. The customer reviews them in design qualification.
URS traceability matrixLinks each URS line to the design document and the test that proves it.
Quality and project plan, inspection and test planSet the inspections, tests, witness points and records for the build.
FAT protocol and reportProve the equipment at your works before shipment. See FAT vs SAT.
SAT protocol and reportProve it again after installation at the customer's site.
IQ and OQ support documentsSupplier protocols or records the customer uses in IQ and OQ, under its own approval.
Turnover packageThe final record set: certificates, weld and surface records, calibration, drawings, software records and manuals. See turnover package.

Annex 15 allows documentation review and some tests done at the FAT to stand without being repeated at IQ or OQ, where that is appropriate and justified and transport and installation do not affect the function. Customers therefore read FAT records closely. A FAT report with missing signatures, an uncalibrated instrument or an open deviation loses that value.

How does OdysseyGPT help?

OdysseyGPT reads documents and checks them against the customer's requirements. Every finding carries a quote from the source page, sheet or cell, and your engineers decide what to do with it. The table maps this sector's documents to the tools.

This sector's documents and the OdysseyGPT tool that reads them
Your taskToolWhat it does
Answer the URS at bid stageDocument ReviewChecks the URS and its supporting specifications against your datasheets, functional specification and standard documents, in both directions, and exports a compliance matrix and a deviations and clarifications list
List what the URS package asks forCustomer Specification Review (beta)Lists technical, quality, documentation and test requirements, each with its clause, and flags ambiguous lines
Track deviations through clarification roundsDeviation Register (beta)Finds declared and undeclared deviations across the requirements, your offer and clarification replies
Track the customer's document listVDRL/MDR Tracker (beta)Turns the required document list into a register with due dates, revisions and status
Check material certificatesMaterial Certificate Review (beta)Checks grade, heat number, chemistry, mechanical results and EN 10204 certificate type against the purchase requirements
Check welding recordsWelding Qualification Review (beta)Checks that WPS, PQR and welder qualifications cover each weld on a weld list. The weld map must be readable as a list or table
Check the inspection and test planITP Validator (beta)Checks the plan against the customer's quality requirements: stages, hold and witness points, acceptance criteria and records
Prepare for the FATFAT Readiness Check (beta) and Calibration Validity Check (beta)Check the FAT procedure, witness notice, open non-conformances and punch items, and that each test instrument was in calibration on the day
Close out the turnover packageMRB Readiness Check (beta) and MRB Compiler (beta)Compare your records with the customer's required index and report missing documents, wrong revisions and unsigned records

The tools read PDF, Word, Excel and CSV files. The post-award tools work from a required index and the records that fill it, which is how a pharmaceutical turnover package is built.

Example: what a URS check looks like

Invented example for illustration. Not a real customer, project, URS or result
URS requirement quotedMaker's document quotedStatusNote
URS-014: "All product-contact metallic parts shall be 316L stainless steel, supplied with EN 10204 type 3.1 certificates."Vessel datasheet, sheet 1: "Wetted parts: 1.4404 (316L). Material certificates EN 10204 3.1 for product-contact parts."CompliesGrade and certificate type both stated.
URS-022: "Product-contact surfaces shall be electropolished to Ra 0.4 µm or better."Standard fabrication specification, section 6: "Internal surfaces mechanically polished to Ra 0.6 µm."DeviatesElectropolish is not in the standard scope. Price it or declare the deviation.
URS-031: "Borescope examination records shall be provided for 100% of product-contact orbital welds."Quality plan, section 4.3: "Borescope examination of 20% of orbital welds, selected by the inspector."DeviatesExamination extent differs. The cost of full examination is not in the base offer.
URS-047: "The vessel and all product pipework shall be fully self-draining."No matching statement found in the datasheet or fabrication specification.Not addressedNothing in the uploaded documents answers this line. An engineer must answer it from the design.
URS-058: "The supplier shall provide a functional specification, software design specification and code review records for the control system."Supplier documentation list, item 12: "Functional design specification and FAT protocol supplied as standard."ClarificationSoftware design specification and code review records are not mentioned.
URS-071: "The FAT protocol shall be submitted for approval at least four weeks before the test."Project plan, section 8: "FAT protocol issued two weeks before the FAT date."DeviatesReview period is shorter than the URS asks for.

Each row quotes both sides, so the engineer can open the page and confirm it. "Not addressed" means the uploaded documents say nothing about the requirement. It does not mean the equipment fails it. The roughness figures and percentages above are made up for the example and are not taken from any standard.

Where OdysseyGPT falls short

  • It does not perform qualification or validation. It does not write, execute or approve DQ, IQ, OQ or PQ.
  • It is not a validation lifecycle system, an electronic quality management system or a document management system, and it does not replace one.
  • It is not validated software under GAMP 5, and we do not offer it as a GxP system of record. Treat its output as a draft that your engineers check.
  • It does not interpret engineering drawings such as P&IDs, isometrics or general arrangements, so it cannot check a slope, a dead leg or a weld position on a drawing.
  • It only checks the documents you upload. A requirement in a document that was never sent cannot be found.
  • We onboard each team ourselves, so there is no self-serve sign-up.

Talk through your tender review

See how OdysseyGPT reviews a tender

Tell us how your team reviews tenders today. We can walk through an example together.

Book a call

Buyer questions

20 questions bid engineers, proposal engineers and buyers ask. Last reviewed:

What is a URS for pharmaceutical equipment?

A user requirement specification is the customer's numbered list of what the equipment must do and be supplied with. It covers the process duty, materials, cleaning and sterilisation, automation, documents and tests. EU GMP Annex 15 makes it a point of reference through the validation life cycle, so each line you accept is likely to be checked again later. See the URS glossary entry.

How should an equipment supplier respond to a URS?

Line by line. Give each numbered requirement a status, say what you offer and name the document that supports it. List every deviation and clarification separately with a reason. Do not answer a whole section with one "complies". The customer will carry your answers into design qualification and testing. A blank format is in the URS response matrix template.

What is a URS compliance matrix?

It is the supplier's table of answers to the URS. Each row holds one requirement, its URS number, what is offered, a status such as complies, deviates or clarification, and a comment. Some customers call it a URS response or traceability matrix. After award, the same rows are extended to show the design document and the test that covers each requirement.

Which standards and guides does a pharmaceutical equipment URS usually call up?

Commonly ASME BPE for hygienic design and fabrication, GAMP 5 for the control system, EU GMP Annex 15 and Annex 11, US cGMP rules in 21 CFR 211, EN 10204 for material certificates and the pressure code the contract names. The customer's own engineering standards sit on top. Check the edition of each one.

Is ASME BPE mandatory for bioprocess equipment?

Not by law. ASME BPE is a voluntary consensus standard. It becomes binding when the purchase order, specification or URS calls it up, which is common for product-contact equipment and piping. Check which edition is named and which parts of your scope it applies to, because applying it to utilities and supports as well changes the cost.

How should I read a surface finish requirement in a URS?

Check three things. First, whether the URS gives a roughness number, an ASME BPE surface finish designation or both, and whether they agree. Second, whether electropolishing is required, because mechanical polishing alone does not meet an electropolished designation. Third, which surfaces the requirement covers and how the finish is to be measured and reported.

What weld documentation do pharmaceutical customers ask for?

Commonly a weld map and weld log for product-contact welds, weld procedures, welder and welding operator qualifications, material certificates linked by heat number, visual or borescope examination records and passivation records. The share of welds to be examined is often higher than a maker's standard practice. Compare the URS with your quality plan and price or declare the difference.

Do product-contact parts need EN 10204 3.1 certificates?

Most URSs ask for them. A type 3.1 certificate reports test results for the material supplied and is validated by the manufacturer's authorised inspection representative, who is independent of the manufacturing department. The difficulty is usually bought-in components, such as valves and instruments, where the certificate has to be requested when you order. See EN 10204 3.1 vs 3.2.

What does GAMP 5 mean for an equipment supplier?

It shapes what the customer asks you for. GAMP 5 is ISPE guidance, not a regulation, and the customer stays responsible for validation. But it encourages customers to rely on supplier documents and testing where they can. So the URS will ask for a software category, specifications, test records and evidence of your quality system. See GAMP 5 for equipment suppliers.

Which GAMP 5 software category applies to a skid control system?

Often more than one. The operating system is infrastructure software, category 1. A standard visualisation package configured for the project is commonly treated as category 4. Control code written for the project is commonly treated as category 5, which attracts the most documentation and testing. The customer decides the classification, so agree it before you price.

Who is responsible for qualifying the equipment, the supplier or the customer?

The customer. Under GMP the drug manufacturer is responsible for qualification and validation. The supplier provides design documents, certificates, FAT and SAT records and often draft protocols. EU GMP Annex 15 says protocols supplied by a third party must be confirmed as suitable by the manufacturing site before approval. Word your URS response to match.

What is design qualification and what does the supplier provide for it?

Design qualification is the documented check that the design meets the URS and GMP, done before the equipment is built. The supplier provides the functional and design specifications, P&IDs, drawings, datasheets, component lists and a traceability matrix. The customer reviews them against the URS. Gaps found here are far cheaper to fix than gaps found at the FAT.

What does a FAT for bioprocess equipment usually cover?

The contract and the approved FAT protocol decide. It commonly covers a check of the equipment against drawings and component lists, a review of the documents, instrument and loop checks, alarm and interlock tests, control sequence tests and functional tests with water or another test medium. Some customers add cleaning coverage tests. See the FAT checklist guide.

Can FAT results be reused in IQ and OQ?

In part. EU GMP Annex 15 allows documentation review and some tests done at the FAT to stand without being repeated at IQ or OQ, where that is appropriate and justified and transport and installation do not affect the function. The customer decides. It depends on your FAT records meeting the customer's standard: approved protocol, signed entries and calibrated instruments.

What is the difference between FAT and SAT for pharmaceutical equipment?

The FAT is run at the supplier's works before shipment. The SAT is run after delivery and installation at the customer's site. Annex 15 says a FAT may be supplemented by a SAT after the equipment is received. The SAT shows the equipment survived transport and works with the site's utilities and systems. See FAT vs SAT.

What goes in a pharmaceutical equipment turnover package?

The customer's index decides. It commonly includes as-built drawings, component and instrument lists, material certificates, elastomer and polymer compliance statements, weld maps and logs, surface finish and passivation reports, pressure test and calibration records, software records, FAT and SAT reports and manuals. Agree the index at the start of the order. See turnover package.

What are the most common deviations in a URS response?

They tend to sit in six places: surface finish and electropolishing, weld examination extent, certificates for bought-in components, software documents and test records, the time allowed for customer review of documents, and who writes or executes IQ and OQ protocols. Each one carries cost or time, so give each its own row with a reason.

How does OdysseyGPT help with a URS?

Document Review checks the URS and its supporting specifications against your datasheets, functional specification and standard documents, in both directions. Each requirement gets a status and a quote from both sides. It exports an editable compliance matrix and a deviations and clarifications list. Your engineers check every row and decide what goes to the customer.

Does OdysseyGPT perform qualification or validation?

No. It reads documents and checks them against the customer's requirements, with a quote for every finding. It does not write, execute or approve DQ, IQ, OQ or PQ. It is not a validation lifecycle system or a quality management system, and it is not validated software under GAMP 5. Treat its output as a draft for an engineer to check.

Can OdysseyGPT help after the order is placed?

Yes, on the documents. The FAT Readiness Check (beta) checks the FAT procedure, calibration evidence and open items before the test. The MRB Readiness Check (beta) compares your records with the customer's required index, and the MRB Compiler (beta) maps approved documents to that index before the turnover package is built. Each finding quotes its source.

Frequently asked questions

Who answers the URS at an equipment manufacturer?

Usually a bid or proposal engineer, with input from process, mechanical, automation and quality staff. Automation and documentation lines often need the most specialist input, because they set the software documents and tests supplied after award.

Does the equipment supplier qualify the equipment?

No. Under GMP the drug manufacturer is responsible for qualification. The supplier provides design documents, FAT and SAT records and often draft IQ and OQ protocols, which the customer reviews and approves under its own procedures.

Does OdysseyGPT validate pharmaceutical equipment?

No. It reads the URS and your documents and reports where they agree, differ or say nothing, with a quote for each finding. It does not perform qualification or validation and is not validated software under GAMP 5.

Can OdysseyGPT read a URS in Excel?

Yes. It reads PDF, Word, Excel and CSV files, and a finding from a spreadsheet cites the sheet and cell. It does not interpret drawings such as P&IDs.

References

EudraLex Volume 4, Annex 15: Qualification and Validation

European Commission

In operation since 1 October 2015. Sections on the URS, design qualification, FAT and SAT, IQ, OQ and PQ.

Visit source

EudraLex Volume 4, Annex 11: Computerised Systems

European Commission

2011 text. A draft revision was published in 2025; check the current version.

Visit source

21 CFR Part 211, Subpart D: Equipment

US Food and Drug Administration, via eCFR

Sections 211.63, 211.65, 211.67 and 211.68.

Visit source

ASME BPE: Bioprocessing Equipment

ASME

Paid standard. Use the edition your contract names.

Visit source

ISPE GAMP 5: A Risk-Based Approach to Compliant GxP Computerized Systems (Second Edition)

ISPE

Paid guide, published July 2022.

Visit source

Related Pages