Glossary term
Design Qualification (DQ)
The documented check, before equipment is built, that its design meets the user requirement specification and good manufacturing practice.
Last reviewed by the OdysseyGPT team
What it is
Design qualification (DQ) is the documented check that the design of equipment meets the user requirement specification and good manufacturing practice. It comes after the URS and before the equipment is built. The drug manufacturer is responsible for it, and it is carried out on the supplier's design documents.
Key Takeaways
- DQ comes after the URS and before fabrication.
- It verifies each URS requirement against the design documents.
- It is the customer's responsibility, run on the supplier's documents.
- Bid-stage deviations must be carried into the design documents, or DQ will reopen them.
Why it matters
Design qualification (DQ) is the stage of qualification that follows the user requirement specification. EU GMP Annex 15 describes it as the element where compliance of the design with GMP is demonstrated and documented, and says the requirements of the URS should be verified during it. In practice the customer, or the customer and supplier together, review the supplier's design documents against the URS line by line: the functional and design specifications, P&IDs, general arrangement drawings, datasheets, component and instrument lists, material and surface finish specifications and the control system design. The result is a record that each requirement is met by the design, or a list of gaps to resolve before fabrication. DQ is the customer's activity, but it runs on the supplier's documents, so the supplier's submission dates set its timing. Gaps found at DQ are cheap to fix compared with gaps found at the FAT. A common weakness is a traceability matrix that points to a document without saying where in the document the requirement is met. Another is a deviation agreed at bid stage that never reached the design documents. Suppliers often call the meeting a design review; DQ is the documented GMP outcome of it.
How OdysseyGPT uses it
OdysseyGPT does not perform or approve design qualification. Document Review can check the URS against your written design documents, such as the functional specification and datasheets, and report each line as complies, deviates, clarification or not addressed, with a quote from both sides. That gives you a list of gaps before the customer's review. It does not interpret P&IDs or other drawings, so requirements proved only on a drawing need an engineer.
Evaluation questions
What documents are reviewed in design qualification?
Typically the functional and design specifications, P&IDs, general arrangement drawings, datasheets, component and instrument lists, material and surface finish specifications, the control system design and the URS traceability matrix.
Frequently asked questions
What is design qualification?
The documented verification that the proposed design of equipment, a facility, a utility or a system meets the user requirement specification and complies with GMP. It is done before the equipment is built.
Who performs design qualification?
The drug manufacturer is responsible for it. The supplier provides the design documents and usually takes part in the review. Some contracts ask the supplier to prepare the DQ record for the customer to approve.
Is design qualification the same as a design review?
They overlap. A design review is an engineering meeting on whether the design is right. Design qualification is the documented GMP record that the design meets the URS. One often feeds the other.
References
EudraLex Volume 4, Annex 15: Qualification and Validation
European Commission
Section on design qualification.