ISO 14644 cleanrooms: what the series asks of an equipment supplier

A plain-English overview of ISO 14644 for applications and project engineers at makers of air handling units, fan filter units, filters and cleanroom panels: the main parts, what an ISO class is, how it relates to EU GMP grades and what to check in a specification.

By Ademola Afolabi, Founder, New Odyssey Ltd · Last reviewed:

The short answer

ISO 14644 is the international series on cleanrooms and associated controlled environments. Part 1 classifies air cleanliness by particle concentration, Part 2 covers monitoring, Part 3 gives test methods and Part 4 covers design, construction and start-up. The class belongs to the finished room. An equipment supplier is asked to show that its equipment and documents support it.

Key Takeaways

  • ISO 14644 is a series. Parts 1 to 4 are the ones an equipment specification cites most often.
  • An ISO class is a statement about a room: a class number, an occupancy state and the particle sizes considered.
  • EU GMP Annex 1 uses grades A to D with its own limits and points to ISO 14644 for methods.
  • No single piece of equipment has an ISO class on its own. The supplier shows performance and evidence that let the room reach it.

See how OdysseyGPT reviews a tender. Tell us how your team reviews tenders today. We can walk through an example together. Book a call

What is ISO 14644?

ISO 14644, Cleanrooms and associated controlled environments, is a series of international standards. It deals with rooms and zones where the concentration of airborne particles is controlled. Electronics, pharmaceutical, medical device, aerospace and hospital projects all use it. It is written around the room and the people who design, build, test and run it. It is not a product standard for an air handling unit or a filter.

That is why it reaches an equipment maker second-hand. The cleanroom designer sets a class for each room. The specification for each piece of equipment then carries the requirements the designer derived from it: filter classes, air flows, leakage, surfaces, test ports and documents.

The parts a specification cites most often

ISO 14644 Parts 1 to 4 in outline (own summary)
PartSubjectWhat it means for an equipment supplier
Part 1Classification of air cleanliness by particle concentration. It defines the ISO classes and how a room is measured against one with a particle counterThe class named in your specification comes from here. It applies to the room, zone or separative device, not to your unit alone
Part 2Monitoring to provide evidence that a cleanroom keeps performing to its class, through a monitoring plan based on riskThe user may ask for sampling points, sensor provisions or data outputs on your equipment
Part 3Test methods for cleanrooms and clean zones, such as air flow, pressure difference, installed filter system leakage, airflow direction and recovery testsFilter housings and fan filter units need to be testable in place. The specification may name which tests are yours
Part 4Design, construction and start-up of a cleanroom, from requirements through to handover, for new and modified installationsIt frames the documents and checks a cleanroom contractor passes down to its suppliers

The series has further parts. Part 5 covers operations and Part 7 covers separative devices such as isolators and clean air hoods. Others deal with subjects such as surface and chemical cleanliness. Check which parts and which editions your specification names. Editions move on: Part 1 was reissued in 2015, Part 3 in 2019 and Part 4 in 2022, for example, and older specifications often cite earlier ones. Confirm the current edition of each part in the ISO catalogue.

What is an ISO class?

Part 1 sets out nine classes, ISO Class 1 to ISO Class 9. A lower number means cleaner air. Each class sets a maximum concentration of particles at and above stated sizes. The standard considers threshold sizes from 0.1 to 5 micrometres for classification. We do not reproduce the limits table here. Take the figures from the edition your contract names.

A class number alone is an incomplete statement. A full one gives three things.

  • The ISO class number.
  • The occupancy state: as-built, with the room complete but no process equipment or people; at-rest, with equipment installed and running but no people; or operational, with the process running and staff present.
  • The particle size or sizes the class was assessed at.

The state matters commercially. A room that meets its class at rest may not meet it in operation, and the difference depends on the process and the people as much as on the air system. If a specification asks you to guarantee a class, check which state it means. The glossary entry on cleanroom classification goes into this.

How ISO classes relate to EU GMP grades

Makers of sterile medicines in the EU follow Annex 1 of the EU GMP guide. Annex 1 does not use ISO class numbers as its own system. It defines four grades, A to D, where grade A is the critical zone. For each grade it gives its own table of particle limits, with separate columns for the at rest and in operation states, and it adds limits for microbial contamination, which ISO 14644-1 does not cover.

ISO 14644 and EU GMP Annex 1 compared at concept level (own summary)
ISO 14644-1EU GMP Annex 1
Who uses itAny industry with a cleanroomManufacturers of sterile medicinal products
ScaleISO Class 1 to 9Grades A, B, C and D
StatesAs-built, at-rest and operationalAt rest and in operation
What is limitedAirborne particle concentrationAirborne particles and microbial contamination
How the two connectSupplies the classification methodRefers to ISO 14644-1 for sampling locations and to the ISO 14644 series for qualification

People often describe a grade by an ISO class. Treat that as shorthand. If a specification gives both a grade and an ISO class, the grade's own limits in Annex 1 govern for a GMP project, and the two should be checked for agreement. Annex 1 also treats classification as one part of cleanroom qualification, alongside tests such as installed filter leakage, air flow, pressure difference, airflow visualisation and recovery, and it sets maximum intervals for requalification. Pharmaceutical projects add documents of their own. See pharmaceutical equipment manufacturers.

What an equipment supplier is asked to show

No air handling unit, fan filter unit or wall panel has an ISO class by itself. The class is measured in the finished room by whoever is contracted to test it. What the supplier provides is equipment that makes the class reachable and evidence that the equipment is what the designer assumed.

  • Air handling units: air flow and pressure at the scheduled duty point, filter stages and classes, casing leakage class, internal surfaces that can be cleaned, and the points an air handling unit specification adds for clean applications.
  • Fan filter units and terminal filter housings: the filter class, an individual test report for each high-efficiency filter, face velocity data, and provision for testing the installed filter for leaks.
  • Filters: the class and the standard it is stated to, such as ISO 16890 for general ventilation stages and EN 1822 for high-efficiency stages.
  • Wall and ceiling panels, doors and pass-throughs: surface materials and finish, joint and seal details, and cleaning agents the surfaces tolerate.
  • Instruments supplied with the equipment: range, accuracy and a calibration certificate for each.
  • Documents: installation and operating instructions, drawings, material and filter certificates, factory test reports and the papers the user needs for installation and operational qualification.

These go to the customer as part of the HVAC submittal and, later, the handover file. For the qualification stages, see IQ, OQ and PQ.

What to check in a cleanroom equipment specification against ISO 14644

Checks to make before you quote cleanroom equipment (own summary)
CheckWhy it matters
Which parts of ISO 14644 are named, and which editionsReused specifications cite superseded editions, and the test methods part has changed over time
The class of each room your equipment serves, with its occupancy state and particle sizesA class with no state cannot be priced or guaranteed
Whether a GMP grade is given as well, and whether it agrees with the ISO classThe grade brings in-operation and microbial limits that the ISO class does not
Whether you are asked to guarantee the room class or only equipment performanceRoom class depends on the envelope, the process and the people, which you may not control
Filter class at each stage and the standard it is stated toClasses from different filter standards are not interchangeable labels
Evidence for high-efficiency filters: individual test reports and who tests the installed filterThe installed leak test is site work with its own equipment and cost
Test ports, access and clearances needed for in-place testsA housing that cannot be tested in place fails at qualification, not at the factory
Casing and ductwork leakage classesLeakage downstream of the final filter stage undermines the room
Surface finish, materials and resistance to the user's cleaning and disinfection agentsThese are judged at design review and are costly to change later
Which Part 3 tests are in your scope, at the factory or on siteAir flow, pressure, recovery and filter leak tests may sit with you, the contractor or a test house
Monitoring provisions: particle counter ports, pressure sensors, data outputsThe user's monitoring plan may need them built in
Qualification documents wanted, their format and who approves themProtocol writing and review cycles take engineering time

Write each gap as a row in your technical deviation list. A layout for the document set is on the HVAC submittal checklist template page. OdysseyGPT's Document Review checks the specification against your product data, test report summaries and offer text, and drafts the compliance matrix and deviation list with a quote for each row. Customer Specification Review (beta) lists the obligations in the specification, one line each. After award, the Calibration Validity Check (beta) matches each instrument on a test report to its certificate.

What OdysseyGPT does not do

OdysseyGPT reads documents. It does not classify a cleanroom, count particles, test a filter or judge whether a room will reach its class. It does not read layout or airflow drawings, and it holds no copy of ISO 14644. Your engineers decide every status. See HVAC and cleanroom equipment manufacturers.

Talk through your tender review

See how OdysseyGPT reviews a tender

Tell us how your team reviews tenders today. We can walk through an example together.

Book a call

Frequently asked questions

What is ISO 14644 used for?

Classifying, testing, monitoring, designing and operating cleanrooms and other controlled environments where airborne particles are limited. It is used across industries, including electronics, pharmaceuticals, medical devices and health care.

How many ISO cleanroom classes are there?

Nine, from ISO Class 1 to ISO Class 9, in ISO 14644-1. A lower number means a lower permitted particle concentration. The limits are in the standard. Use the edition your contract names.

Is an ISO class the same as a GMP grade?

No. EU GMP Annex 1 grades A to D have their own particle limits for the at rest and in operation states, plus microbial limits. Annex 1 points to ISO 14644 for methods. A grade is often described by an ISO class, but the two are separate systems.

Can a fan filter unit or air handling unit be ISO 14644 certified?

The classification in Part 1 applies to a room, clean zone or separative device as tested, not to a unit on its own. A supplier shows filter classes, test reports and performance data that support the room's class.

Does OdysseyGPT classify or test cleanrooms?

No. It checks specification and project documents against the customer's written requirements and quotes its sources. Classification is measurement work on the installed room by qualified people.

References

ISO 14644-1:2015 Cleanrooms and associated controlled environments. Part 1: Classification of air cleanliness by particle concentration

ISO

Paid standard. Catalogue abstract used for scope and the particle size range considered.

Visit source

ISO 14644-2:2015 Part 2: Monitoring to provide evidence of cleanroom performance related to air cleanliness by particle concentration

ISO

Paid standard. Title and catalogue entry only. Check the ISO catalogue for a later edition.

Visit source

ISO 14644-3:2019 Part 3: Test methods

ISO

Paid standard. Title and catalogue entry only.

Visit source

ISO 14644-4:2022 Part 4: Design, construction and start-up

ISO

Paid standard. Catalogue abstract used for scope and for the reference to Parts 5 and 7.

Visit source

EudraLex Volume 4, Annex 1: Manufacture of Sterile Medicinal Products (2022)

European Commission

Free. Used for the grades, the two states, the qualification tests and the references to ISO 14644.

Visit source