OdysseyGPT

Standards explainer

ASME Section III explained: nuclear component classes, N-type certificates and what to check in a tender

A plain-English overview of ASME BPVC Section III for quality and project engineers at component makers, covering the divisions, the classes, the certificates and the inspector, and ending with a tender checklist.

By Ademola Afolabi, Founder, New Odyssey Ltd · Last reviewed:

The short answer

ASME Section III is the part of the ASME Boiler and Pressure Vessel Code with rules for construction of nuclear facility components. It sorts components into classes, each with its own subsection of rules. A manufacturer needs an N-type certificate of authorization, works under an Authorized Nuclear Inspector and certifies each item on a data report.

Key Takeaways

  • Section III covers nuclear facility components. Division 1 holds the rules for metallic components and supports.
  • The class of a component is set in the owner's design specification, not chosen by the manufacturer.
  • N-type certificates rest on a survey of the quality assurance programme, and each certificate names a scope.
  • The purchaser's specification adds requirements beyond the code. Those additions are where most exceptions arise.

Free sample: a certificate check report. Send up to 20 material certificates and the PO. Get a certificate check report. Get the free result

What does ASME Section III cover?

Section III of the ASME Boiler and Pressure Vessel Code is titled Rules for Construction of Nuclear Facility Components. In the code, construction takes in materials, design, fabrication, examination, testing, inspection and certification. The rules apply to new components. Inspection of a plant in service is the subject of a different section of the code, Section XI.

In the United States the code has legal force. The regulation 10 CFR 50.55a incorporates named editions of Section III Division 1 by reference, with conditions, and ties the reactor coolant pressure boundary to the Class 1 rules. Elsewhere the code applies because the plant design and the contract call for it. In both cases the edition is fixed by the plant's licensing basis and the purchase order, not by the date of the enquiry.

Divisions and subsections

Section III by division and subsection, at name level (own summary of public listings; check the edition your contract names)
PartSubject
Subsection NCAGeneral requirements for Division 1 and Division 2: responsibilities, quality assurance, authorised inspection, certificates, marks and data reports
Division 1, Subsection NBClass 1 components
Division 1, Subsection NCDClass 2 and Class 3 components. Editions before 2021 held these in two subsections, NC and ND
Division 1, Subsection NEClass MC components, which are metal containment
Division 1, Subsection NFSupports
Division 1, Subsection NGCore support structures
AppendicesMandatory and nonmandatory appendices, including the data report forms
Division 2Code for concrete containments
Division 3Containment systems for transport and storage of spent nuclear fuel and high-level radioactive material
Division 4Fusion energy devices
Division 5High temperature reactors

Section III calls up other sections: Section II for materials, Section V for examination methods and Section IX for welding qualifications. A purchase order that names Section III brings those with it. Most equipment makers work in Division 1.

Classes of components

Division 1 does not have one set of rules for all components. It has classes, and each class has a subsection. Class 1 carries the most demanding rules. Class 2 and Class 3 follow. Class MC is for metal containment and Class CS for core support structures. A support takes its rules from the class of the component it holds.

The code does not tell you which class an item belongs to. That decision belongs to the plant owner or its designee, and it is recorded in the design specification the owner provides. In the United States, Regulatory Guide 1.26 gives the regulator's view on sorting components into quality groups A to D, and 10 CFR 50.55a links groups B and C to Class 2 and Class 3. The manufacturer answers the design specification with a design report where the code calls for one.

Read the class on every line

One valve order can hold Class 1, Class 2 and non-code items. The class changes the material requirements, the examination, the documents and the price. If a line item has no class, ask before you quote.

N-type certificates of authorization

To build to Section III and apply the ASME Certification Mark, an organisation must hold an ASME certificate of authorization for the work. ASME issues it after a survey of the organisation's quality assurance programme and how it is put into practice. Each certificate names a scope and a location, and is issued for a limited term, so ask for the current one.

Section III certificate designators as ASME's certification page lists them (own summary)
DesignatorScope in outline
NComponents: vessels, pumps, valves, piping, storage tanks and core support structures, among others
NAField installation and shop assembly
NPTParts, appurtenances, welded tubular products and piping subassemblies
NSSupports
NVPressure relief valves
N3Transport and storage containments under Division 3
OWNThe owner's certificate, for the owner of a nuclear power plant

Material comes through a parallel route. A material organisation can hold an ASME Quality System Certificate, which covers its quality system for making and supplying material under Section III. A certificate holder can also qualify a material supplier itself. Either way the material arrives with a certified material test report. The quality assurance programme behind all of these certificates draws on ASME NQA-1.

The Authorized Nuclear Inspector

A certificate holder must have an agreement with an Authorized Inspection Agency. The agency provides an Authorized Nuclear Inspector (ANI): an inspector who holds a National Board commission with the nuclear endorsement, N, for Section III Division 1. There are separate endorsements for concrete work and for inspection in service, and a supervisor endorsement above them.

The ANI is independent of the manufacturer. The inspector monitors the quality assurance programme, verifies that the code requirements for the item have been met and signs the data report. The data report is an ASME form, and the form depends on the item: N-1 for vessels, NPV-1 for pumps and valves, NPP-1 for piping subassemblies, N-2 for identical parts and NF-1 for supports are examples.

The ANI works to the code. The purchaser's own inspector works to the purchase order. On most nuclear orders both attend, so the ITP needs a column for each.

How does Section III differ from Section VIII?

Section III and Section VIII compared at scope level only (own summary)
PointSection IIISection VIII
SubjectComponents of nuclear facilities: vessels, pumps, valves, piping, supports, containmentPressure vessels in general industry
How it is dividedBy class of component, set by the ownerBy division: general rules, alternative rules and high-pressure vessels
Quality systemA quality assurance programme drawing on NQA-1A quality control system described in the code
CertificatesN-type certificates, such as N, NPT, NS and NVU, U2 and U3
InspectorAuthorized Nuclear Inspector, with a nuclear endorsementAuthorized Inspector
MaterialFrom a qualified material organisation, with certified material test reportsTo the material specification, with the reports the code and the order require
Design documentsOwner's design specification, and a design report from the manufacturer where requiredUser's requirements or design specification, depending on the division
Regulatory tie in the USIncorporated by reference in federal nuclear regulationAdopted by states and other jurisdictions

A shop that holds a U certificate cannot build Section III items on the strength of it. The certificates, the inspector's endorsement and the quality programme are all separate. For the general industry code, see ASME Section VIII.

What to check in a tender against ASME Section III

Section III points to settle before you quote
CheckWhy it matters
Division, subsection and class for each line itemThe class decides the rules, and one order can mix classes
Edition and addenda, and any code cases the purchaser allows or requiresThe licensing basis may fix an edition older than the one your procedures use
Whether the Certification Mark is required, and whether your certificate covers the designator, scope and locationSome purchasers buy to the technical rules of the code without the mark; the order must say which
Who provides the design specification, and whether you must produce a design reportDesign responsibility changes the price and the people you need
The quality assurance requirements, including the NQA-1 editionThe code and the purchaser may each name one
Material: source, qualification of the material organisation, and the content of each CMTRMaterial from an unqualified source needs qualification or dedication before use
Welding and NDE requirements beyond the code, and personnel qualificationExisting procedure qualifications may not cover the additions
Purchaser hold and witness points in addition to the ANI'sTwo sets of notice periods set the schedule
Seismic and environmental qualification, if the specification asks for itIt is usually governed by other standards and can mean a separate test programme
Data report form, and any registration the purchaser requiresIt decides the final certification paperwork
Sub-suppliers: who needs a certificate, and who you qualify yourselfCastings, forgings, bolting and weld filler each need a qualified source
Records to deliver and records to keep, with the retention periodRecord requirements reach every sub-supplier

OdysseyGPT's Document Review compares the purchaser's specification package with your own standard specification and drafts a compliance matrix and a list of exceptions, each row quoting its source. After award, Material Certificate Review (beta) checks material test reports against the material purchase requirements, and Welding Qualification Review (beta) checks whether your welding records cover the welds on your weld list.

What OdysseyGPT does not do

It does no design or stress analysis and does not decide whether an item meets the code. That is for your engineers, your quality assurance programme and the Authorized Nuclear Inspector. It does not hold the text of the code and does not read drawings. It is not software qualified under a nuclear quality programme, so qualified people must verify what it reports.

Try it on your own documents

Free sample: a certificate check report

Send up to 20 material certificates and the PO. Get a certificate check report.

Get the free result

Frequently asked questions

What is ASME Section III?

The section of the ASME Boiler and Pressure Vessel Code titled Rules for Construction of Nuclear Facility Components. It covers materials, design, fabrication, examination, testing, inspection and certification of new nuclear components.

What are Class 1, Class 2 and Class 3 components?

Classes of component in Section III Division 1, each with its own rules. Class 1 has the most demanding rules. The plant owner assigns the class in the design specification. In the US, the reactor coolant pressure boundary is tied to Class 1.

What is an N stamp?

The everyday name for the ASME Certification Mark with the N designator. It shows that an organisation holding an ASME N certificate of authorization built the component to Section III under an Authorized Nuclear Inspector.

What is the difference between ASME Section III and Section VIII?

Section III covers components of nuclear facilities and sorts them by class. Section VIII covers pressure vessels in general industry and is split into three divisions. The certificates, inspectors and quality requirements are separate.

What is an Authorized Nuclear Inspector?

An inspector employed by an Authorized Inspection Agency who holds a National Board commission with the nuclear endorsement. The inspector is independent of the manufacturer, verifies code requirements and signs the data report.

References

Nuclear Component Certification

ASME

Lists the N-type designators and their scopes.

Visit source

Nuclear Material Organization Certification

ASME

Visit source

ASME Data Report Forms

ASME

Lists the Section III forms by number and title.

Visit source

Commissions and endorsements

National Board of Boiler and Pressure Vessel Inspectors

Lists the nuclear endorsements.

Visit source

10 CFR 50.55a: Codes and standards

US Nuclear Regulatory Commission (eCFR)

Visit source

Regulatory Guide 1.26: Quality Group Classifications and Standards for Water-, Steam-, and Radioactive-Waste-Containing Components of Nuclear Power Plants

US Nuclear Regulatory Commission

Visit source

BPVC Section III, Subsection NCA: General Requirements for Division 1 and Division 2

ASME (ANSI webstore listing)

Paid code. Used for the title and scope of the volume only.

Visit source

Related Pages