Glossary term
10 CFR 50 Appendix B
The US Nuclear Regulatory Commission regulation that sets eighteen quality assurance criteria for safety-related structures, systems and components of nuclear power plants.
Last reviewed by the OdysseyGPT team
What it is
10 CFR 50 Appendix B is the US Nuclear Regulatory Commission regulation that sets eighteen quality assurance criteria for safety-related structures, systems and components of nuclear power plants. It binds applicants and licensees, who pass it to suppliers through procurement documents. Most suppliers meet it by working to ASME NQA-1.
Key Takeaways
- Eighteen criteria, from organisation to audits.
- It binds licensees; suppliers are bound through the purchase order.
- Evidence that a purchased item conforms must reach the plant before the item is used.
- NQA-1 is the usual way a supplier shows it meets the criteria.
Why it matters
Appendix B to Part 50 of Title 10 of the US Code of Federal Regulations is titled Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants. It applies to applicants and licensees, and covers activities that affect the safety-related functions of structures, systems and components, from design and purchasing through fabrication, inspection, testing and modification. It defines quality assurance as the planned and systematic actions needed to give adequate confidence that an item will perform satisfactorily in service. The appendix has eighteen criteria. They run from organisation and the quality assurance programme, through design control, procurement document control, control of purchased material, special processes, inspection, test control and calibration, to nonconforming items, corrective action, records and audits. An equipment maker is not a licensee, so the appendix reaches it through the purchase order. The criterion on procurement documents requires those documents to carry the applicable requirements and, where necessary, to require the contractor to have a quality assurance programme consistent with the appendix. The criterion on purchased material requires documentary evidence of conformance to be at the plant before the item is installed or used. Most suppliers show compliance by working to ASME NQA-1, whose eighteen requirements match the criteria one for one.
How OdysseyGPT uses it
OdysseyGPT does not audit or approve a quality assurance programme and is not software qualified under one. Document Review compares a purchaser's quality requirements with your own documents and drafts a compliance matrix, so a clause that invokes Appendix B, names an NQA-1 edition or sets a record retention period appears as a row with its source quoted. Qualified people verify each row.
Evaluation questions
What does it mean when a purchase order invokes Appendix B?
That the item is safety-related and the supplier must make it under a quality assurance programme meeting the eighteen criteria. Expect an audit by the purchaser, flow-down to sub-suppliers, controlled records and, on US orders, a 10 CFR Part 21 clause.
How long must quality records be kept under Appendix B?
The appendix does not give one period. It requires records to be identifiable and retrievable, and leaves the applicant to set retention rules. A supplier's retention period therefore comes from its purchase order.
Frequently asked questions
What is 10 CFR 50 Appendix B?
A US federal regulation that sets eighteen quality assurance criteria for the safety-related structures, systems and components of nuclear power plants and fuel reprocessing plants.
What are the 18 criteria of Appendix B?
Organization; quality assurance program; design control; procurement document control; instructions, procedures and drawings; document control; control of purchased material, equipment and services; identification and control of materials, parts and components; control of special processes; inspection; test control; control of measuring and test equipment; handling, storage and shipping; inspection, test and operating status; nonconforming materials, parts or components; corrective action; quality assurance records; and audits.
Does Appendix B apply to suppliers?
Not directly. It binds applicants and licensees. They pass it to suppliers through procurement documents, so a supplier is bound by its purchase order.
What is the difference between Appendix B and NQA-1?
Appendix B is the regulation and states what must be controlled. NQA-1 is an ASME standard that gives more detail on how. The US regulator accepts named NQA-1 editions, with conditions, as a way to meet Appendix B.
References
Appendix B to 10 CFR Part 50: Quality Assurance Criteria for Nuclear Power Plants and Fuel Reprocessing Plants
US Nuclear Regulatory Commission (eCFR)
Regulatory Guide 1.28, Revision 6: Quality Assurance Program Criteria (Design and Construction)
US Nuclear Regulatory Commission