Glossary term
Manufacturer's Data Report (MDR)
The ASME form on which a manufacturer certifies how a boiler or pressure vessel was built, countersigned by the Authorized Inspector.
Last reviewed by the OdysseyGPT team
What it is
A manufacturer's data report is the ASME form on which a certified manufacturer records how a boiler or pressure vessel was built: materials, design conditions, heat treatment, examination and test. The manufacturer and the Authorized Inspector both sign it. For Section VIII Division 1 the usual forms are U-1 and U-1A.
Key Takeaways
- One data report per stamped vessel, on an ASME form.
- Signed by the manufacturer and by the Authorized Inspector.
- Parts made by another certified manufacturer bring partial data reports.
- Customers usually want the signed report in the record book.
Why it matters
A manufacturer's data report is a form set by the ASME Boiler and Pressure Vessel Code. The manufacturer completes one for each stamped item. It records who built the vessel and for whom, the code edition, the drawing, the materials and thicknesses, the design pressure and temperature, the heat treatment, the examination carried out and the pressure test. It ends with two certificates: one signed by the manufacturer and one signed by the Authorized Inspector, who gives a National Board commission number. For Section VIII Division 1 the usual forms are U-1 and the shorter U-1A. A part supplied by another certified manufacturer comes with a partial data report. The manufacturer can register the report with the National Board, which keeps it on file and gives the vessel a National Board number. Do not confuse this with a master document register, which some projects also shorten to MDR.
How OdysseyGPT uses it
OdysseyGPT does not complete or sign data reports. MRB Readiness Check (beta) compares your documentation folder with the customer's record book index and reports required documents that are missing, at the wrong revision or incomplete, which includes a missing or unsigned data report. MRB Traceability Verification (beta) checks the links between records inside the book.
Evaluation questions
Does the data report have to be registered with the National Board?
It depends on where the vessel will be installed and on the purchase order. Many jurisdictions and owners require registration. Check the requisition before you quote, because it changes the nameplate.
What should a quality engineer check on a data report before handover?
That the tag, serial number, code edition, materials, design conditions, heat treatment, examination and test pressure agree with the drawings and records in the book, and that both certificates are signed and dated.
Frequently asked questions
What is a U-1 form?
The manufacturer's data report for a pressure vessel built to ASME Section VIII Division 1. U-1A is a shorter alternative form. Both are signed by the manufacturer and the Authorized Inspector.
Who signs a manufacturer's data report?
A representative of the manufacturer signs the certificate of shop compliance. The Authorized Inspector signs the certificate of shop inspection and gives a National Board commission number.
What is a partial data report?
A data report for a part, such as a head or a channel, made by one certified manufacturer for another. The vessel manufacturer attaches it to the final data report.
Is the data report the same as the manufacturing record book?
No. The data report is one certified form. The record book is the indexed set of all the build records, and the data report is one of the documents in it.
References
Form U-1A: Manufacturer's Data Report for Pressure Vessels (alternative form)
ASME
Electronic Data Transfer (data report registration)
National Board of Boiler and Pressure Vessel Inspectors