The short answer

NSF/ANSI/CAN 61 is the North American standard that sets minimum health effects requirements for products and materials in contact with drinking water. It limits the chemical contaminants a product may release into the water. It says nothing about performance. A supplier shows compliance with a listing from an accredited certification body such as NSF or UL Solutions.

Key Takeaways

  • NSF/ANSI/CAN 61 is about what leaches from a product into drinking water. It is not a performance or durability standard.
  • Compliance is shown by a third-party listing for a named product, not by a maker's statement.
  • A listing is specific. It names the product, and may limit sizes, materials and water temperature.
  • NSF/ANSI/CAN 372 covers lead content and is a separate evaluation, often asked for with 61.

See how OdysseyGPT reviews a tender. Tell us how your team reviews tenders today. We can walk through an example together. Book a call

What is NSF/ANSI/CAN 61?

NSF/ANSI/CAN 61, Drinking Water System Components: Health Effects, sets minimum health effects requirements for the chemical contaminants and impurities that products and materials can pass into drinking water. It applies from the source to the tap: to anything that touches drinking water or a drinking water treatment chemical on the way. The three parts of the name show that it is published by NSF and is a national standard in both the United States and Canada. Most people shorten it to NSF 61.

The standard is narrow on purpose. By its own scope it does not set performance, taste and odour or microbial growth requirements. A valve listed to it has been evaluated for what it releases into the water. Whether it seals, lasts or meets a pressure rating is a matter for the product standard, such as one of the AWWA standards. Point-of-use treatment devices for homes are covered by other NSF standards, and treatment chemicals themselves by NSF/ANSI/CAN 60.

In the United States the standard gets its force from state drinking water regulations and plumbing codes that require products in public water systems to conform, and from project specifications. Canadian provinces and territories refer to it in a similar way. Check what the authority for your project requires.

Which products does NSF/ANSI/CAN 61 cover?

The standard is divided into sections by product type, and each type is evaluated in its own way. The table is our own summary of how NSF describes them.

Product groups in NSF/ANSI/CAN 61 (own summary of public NSF descriptions)
Product groupExamplesWhat a supplier should note
Pipes and related productsPipe, tubing, hose and fittingsA listing may be limited to a size range and to cold or hot water
Barrier materialsCoatings, linings and paints applied to tanks, pipe, valves and pumpsThe listing belongs to the coating product. It can set limits on how the coating is applied and cured
Joining and sealing materialsGaskets, sealants, adhesives and lubricantsSmall parts, but a section that says "all wetted materials" includes them
Process mediaFilter media, activated carbon and ion exchange resinsListed by product and grade
Mechanical devicesIn-line valves, water meters, filters, chemical feeders and process equipmentWhere most treatment plant equipment sits. Confirm with your certifier which section your product is evaluated under
Mechanical plumbing devicesTaps, drinking fountains and other devices at the end of the line inside buildingsSeldom relevant to plant equipment

A component can be certified on its own, and so can a finished product. They are not the same thing. Using a certified coating or a certified gasket helps the evaluation of the finished valve or pump, but it does not make the assembly certified. NSF gives the example of a chemical feed pump: certifying the pump does not certify the tubing as a product in its own right.

Who certifies products, and what is a listing?

NSF wrote the standard and is also the best-known certifier, which is why the two are often confused. Other accredited certification bodies certify to the same standard, among them UL Solutions and IAPMO R&T. A mark from any of them is evidence of certification to the standard. Some specifications name one body. If yours does and your listing is from another, raise it before bid day.

Certification follows broadly the same path at each body. As NSF describes it, the maker applies and discloses the formulation of every material that touches water. Toxicologists review the formulations and decide which chemical analyses are needed. The production site is audited. Samples are exposed to test waters, the water is analysed, and the results are judged against health-based criteria. Those criteria now sit in a companion document, NSF/ANSI/CAN 600, which the standard refers to.

A product that passes is entered in the certifier's public directory. That entry is the listing. Certification does not end there: NSF describes annual review, unannounced inspections of the production site and periodic retesting. A change of material, supplier or production site can affect the listing, so a listing checked last year should be checked again for a new order.

Read the listing, not the logo

The directory entry names the company, the production site, the product or model and any conditions, such as size range, water contact temperature or the materials covered. An engineer reviewing a submittal compares that entry with the model and options on the order. A mark on a brochure does not show which variants are covered.

How does NSF/ANSI/CAN 61 relate to NSF/ANSI/CAN 372 and lead content?

The two standards ask different questions. NSF/ANSI/CAN 61 asks what a product releases into water, lead included. NSF/ANSI/CAN 372 asks how much lead the product contains, worked out as a weighted average over the wetted surfaces of its materials.

The second question comes from United States law. The Safe Drinking Water Act defines "lead free" for pipes, fittings and fixtures as a weighted average of not more than 0.25 per cent lead across the wetted surfaces, and the Environmental Protection Agency's rule requires manufacturers and importers to certify that covered products meet it. The Act exempts some products, including fire hydrants and water distribution main gate valves of 2 inches and larger. NSF states that products certified to NSF/ANSI/CAN 61 also meet NSF/ANSI/CAN 372 unless the Act exempts them.

For a supplier the practical point is that a specification may ask for both, in one sentence or two. Answer each one. If your product falls under a statutory exemption, say which, and do not assume the engineer's specification allows the exemption. A project specification can ask for more than the law does.

What is a supplier asked to submit?

  • A copy of the current listing from the certification body's directory for the product offered, showing the model, size and material covered.
  • The listing for each coating or lining applied to wetted surfaces, where the finished product is not itself listed.
  • A statement tying the listing to this order: the model and options to be supplied are the ones the listing covers.
  • Evidence of lead content compliance, or the exemption relied on, where the specification or the law asks for it.
  • For site-applied or shop-applied coatings, the application and cure records, where the listing sets conditions for them.
  • The UK equivalent where the project is in the United Kingdom. The buyer may ask for approval under Regulation 31 for products a water company uses in public supply, or for WRAS approval for fittings in premises. Neither is the same as an NSF/ANSI/CAN 61 listing.

These items go into the certificates part of a construction submittal. They are usually wanted with the first submission, before the product data is approved, and are tracked on the submittal log like any other item.

What to check in a tender that names NSF/ANSI/CAN 61

Checks to make before you quote against a drinking water contact requirement
CheckWhy it matters
Does the requirement apply to this equipment at allWastewater and raw water equipment may sit in a manual whose general sections copy a potable water clause. Ask if it is unclear
Whether the section wants the finished product listed or only its wetted materials"Certified product" and "certified materials" are different offers with different evidence
Model, size and material on the schedule against the listingA listing can stop short of the largest sizes or exclude an optional material
Coatings and linings named in the section against the listed coatingA named coating that is not the one your listing was granted with may void the evidence
Water temperature and any other condition on the listingSome listings are for cold water contact only
Elastomers, lubricants and sealantsA wording such as "all materials in contact" reaches the small parts
Which certification body the section namesSome sections name one. Raise a clarification if your listing is from another accredited body
Lead content wording, and any exemption you rely onThe section may ask for more than the statute
Production site on the listing against where this order will be madeListings are tied to sites. A second works may not be covered
When the evidence is dueOften with the first submittal. A listing that is still in progress is an exception to declare
Any national approval asked for in place of or as well as the listingRegulation 31 and WRAS approval in the United Kingdom are separate regimes with their own lists

OdysseyGPT cannot certify a product or confirm that a listing is valid. Only the certifier's directory shows that. What it does is read documents: Document Review checks a specification section against your product data, certificates and scope letter and shows, with a quote from each, where the section asks for drinking water contact evidence that your package does not state. An engineer then checks the listing itself. For the whole bid and submittal process, including the shop drawing submittal, see the page for water and wastewater equipment manufacturers.

Talk through your tender review

See how OdysseyGPT reviews a tender

Tell us how your team reviews tenders today. We can walk through an example together.

Book a call

Frequently asked questions

What does NSF 61 certified mean?

An accredited certification body has evaluated the product against NSF/ANSI/CAN 61 and entered it in its public directory. The evaluation covers the contaminants the product may release into drinking water. It does not cover how well the product performs.

Is NSF 61 the same as NSF 372?

No. NSF/ANSI/CAN 61 deals with what leaches from a product into drinking water. NSF/ANSI/CAN 372 deals with the lead content of the product's wetted materials. Specifications often ask for both.

Is NSF 61 required by law?

It depends on the jurisdiction. Many US state drinking water regulations and plumbing codes require conformance for products used in public water systems, and Canadian jurisdictions refer to the standard. On a project, the specification is what binds the supplier.

Can a body other than NSF certify to NSF/ANSI/CAN 61?

Yes. Accredited certification bodies such as UL Solutions and IAPMO R&T certify to the standard and keep their own directories. Check whether your specification names a particular body.

Does NSF 61 apply to wastewater equipment?

The standard is written for products in contact with drinking water and drinking water treatment chemicals. If a wastewater equipment section cites it, ask the engineer whether the clause is intended.

References

NSF/ANSI/CAN 61: Drinking Water System Components, Health Effects

NSF

Scope and exclusions. The standard is a paid document; use the edition your contract names.

Visit source

NSF/ANSI/CAN 61 testing and certification

NSF

Product sections, certification steps and annual follow-up, as NSF describes them.

Visit source

NSF 61, NSF 372 and lead content

NSF

How the two standards relate.

Visit source

Overview of NSF/ANSI/CAN 600 and updated health effects criteria

NSF

Where the health-based criteria now sit.

Visit source

FAQs: certified components vs end products in the water industry

NSF

Why a certified component does not make a certified assembly.

Visit source

Use of lead free pipes, fittings, fixtures, solder and flux for drinking water

US Environmental Protection Agency

The statutory lead free definition, the certification rule and the exemptions. Read 15 Nov 2026.

Visit source

Health effects and lead content: drinking water products

UL Solutions

A second certification body's description of its service and directory.

Visit source

Water systems certification

IAPMO R&T

A third certification body listing NSF/ANSI/CAN 61 among its standards.

Visit source

What is Regulation 31?

Drinking Water Inspectorate

The UK regime for products used by water companies in public supply.

Visit source