What is ISO 5208?
ISO 5208 is titled Industrial valves — Pressure testing of metallic valves. ISO's abstract says it specifies the examinations and tests a valve manufacturer needs to carry out to establish the integrity of the pressure boundary of a metallic industrial valve, and to verify how tight the closure is and whether the closure mechanism is structurally adequate.
It is not meant to stand alone. The abstract says it is intended to be applied with the specific requirements of a valve product standard, to the extent that the product standard cites it. Where the two differ, the product standard's requirements apply. The standard does not deal with the safety aspects of pressure testing; those stay with the test shop.
The current edition is the fourth, published in 2015. ISO reviewed and confirmed it in 2025. Older orders may still name the 2008 edition, which has been withdrawn, or an earlier one, and the leakage rate table has changed over the editions. Test to the edition the contract names.
The tests ISO 5208 sets
| Test | What it proves | What a tender tends to change |
|---|---|---|
| Shell test | The body, bonnet and their joints hold pressure with no visible leakage through the pressure boundary | Test fluid, water quality and a longer hold time |
| Backseat test | The stem backseat seals, on valves that have this feature | Whether it is required at all, and its record |
| Closure (seat) test | The obturator seals against the seat within the leakage rate specified | Liquid or gas, test direction, both seats or one, and the rate letter |
The standard allows the closure test to be made with a liquid or with a gas, and the allowable leakage is stated differently for each. A low-pressure gas test and a high-pressure liquid test show different things about a seat. If the enquiry asks for both, each one is a line in the test procedure and in the price.
Duration and pressure depend on valve size and rating, and the tables for them are in the standard. Do not take them from a summary, including this one.
Leakage rates as lettered categories
ISO 5208 does not give one pass mark for seat leakage. It gives a series of rates named by letter, running from Rate A through to Rate G. The 2015 edition also has intermediate rates with doubled letters. Rate A is the tightest: no visually detectable leakage for the duration of the test. Each later rate allows more leakage, and the allowance grows with the nominal size of the valve.
- The rate is chosen by the valve product standard, or by the purchaser where the product standard leaves it open.
- Soft-seated valves are commonly ordered to Rate A. Metal-seated valves are commonly ordered to one of the later rates.
- A rate letter is tied to its edition. The same letter in an older edition, or in another standard, may allow a different amount.
- The test fluid matters. A rate met with liquid is not evidence that the valve meets the same letter with gas.
"Zero leakage" is not a rate
Tenders sometimes ask for zero leakage or bubble-tight shut-off without naming a rate. Ask the customer to state the ISO 5208 rate, the test fluid and the test pressure. Then check that your seat design is offered to that rate, and record any difference as a deviation.
ISO 5208, API 598 and EN 12266
| Standard | Where you meet it | How seat leakage is specified |
|---|---|---|
| ISO 5208 | ISO valve product standards and many international project specifications | A lettered rate, chosen by the product standard or purchaser |
| API 598 | Valves built to API product standards such as API 600 and API 602 | No visible leakage for resilient seats; an allowance by valve size for metal seats |
| EN 12266-1 and EN 12266-2 | Valves to European product standards, often with the Pressure Equipment Directive | Lettered rates in Part 1, which holds the mandatory tests; Part 2 holds supplementary tests |
EN 12266-1 was drawn up on the basis of an earlier edition of ISO 5208, so the two look alike. They are separate documents with their own editions, and EN 12266-1 labels its tests with codes for shell strength, shell tightness and seat tightness. Do not assume that a letter in one standard equals the same letter in the other. Compare the tables in the editions named.
A valve built to API 6D is tested to API 6D's own clauses, which refer to ISO 5208 rates for seat leakage. An enquiry that names API 598 on the datasheet and an ISO 5208 rate in the project specification is asking for two acceptance bases. Raise it before you quote.
What to check in a tender against ISO 5208
| Check | Why it matters |
|---|---|
| Edition of ISO 5208 named, and the product standard that calls it up | The product standard governs where they differ |
| Leakage rate letter for each valve type and seat type in the enquiry | No letter means no acceptance criterion |
| Closure test fluid: liquid, gas or both | Allowances differ by fluid, and a gas test needs its own set-up |
| Seats and directions to be tested | Bidirectional valves and double-seated valves take more test steps |
| Any second test standard named elsewhere in the package | API 598, EN 12266-1 or an owner standard may conflict with the rate |
| Hold times or pressures above the standard's minimums | They change test bay throughput on a large order |
| Water quality limits and drying after test | Chloride limits apply to stainless steels in many owner standards |
| Who attends: customer, third party or manufacturer only | Attendance points go into the inspection and test plan |
| Form of the test certificate and what it must state | Rate, fluid, pressure, duration and gauge identity are usual requests |
| Calibration evidence for gauges and recorders | Certificates must be valid on the test date |
OdysseyGPT's Document Review reads the enquiry package and your standard test procedure together, and reports where the customer's test clauses ask for more than you offer, quoting both documents. For the records after testing, the Calibration Validity Check (beta) matches each gauge named on a test report to its certificate. OdysseyGPT does not test valves or issue test certificates. For a certificate layout, see the valve test certificate checklist.