OdysseyGPT

Free template

Valve test certificate checklist: reviewing a pressure test certificate before shipment (Excel and CSV)

For valve manufacturers and stockists: fifteen checks that compare a pressure test certificate with the order and the approved test procedure.

By Ademola Afolabi, Founder, New Odyssey Ltd · Last reviewed:

The short answer

A valve pressure test certificate records the shell and closure tests made on a valve before shipment. This free Excel checklist reviews one: tag and serial number, size and class, the test standard and edition, tests performed against tests ordered, medium, pressure and duration for each, results, gauge calibration, witness and deviations.

Key Takeaways

  • Start from what the order requires, then look at the certificate. A certificate can be complete and still miss a test the customer added.
  • Each closure test needs an entry for every seat or direction tested.
  • Pressures and durations in the checklist are your approved procedure's. The template supplies none.
  • The example has 15 checks on an invented ball valve certificate (PTR-EX-0871-04), with two fails and four queries.

Download the valve test certificate checklist

Both files are free under CC BY 4.0, with no form to fill in. The XLSX opens in Excel, Google Sheets, LibreOffice and Numbers. The CSV carries the table only; the header block is in the XLSX.

Why review the certificate before the valve ships

The pressure test certificate is the document a receiving inspector opens first. If a seat test has no entry or the gauge was out of date, the valve is quarantined at the customer's site and the argument starts there. Ten minutes with this checklist, after testing and before the certificate is signed, moves that argument back into your own test bay where it can still be fixed.

  • Quality engineers at valve manufacturers, on each certificate or on a sample the quality plan sets.
  • Stockists and modification shops, who retest valves and issue their own certificates.
  • Buyers' inspectors, who can use the same rows at goods-in.

Which tests a valve needs, and at what pressure and for how long, depends on the valve type, size and class and on the test standard the order names, commonly API 598 or ISO 5208. The two are not interchangeable. Check the governing standard or contract. See also valve manufacturers.

Header block

Header block fields, with the invented example values
FieldExample
ProjectExample Gas Compression Station, Phase 2 (fictional)
CustomerExample EPC Contractor Ltd (fictional)
Purchase orderPO-EX-3105 (fictional)
Equipment / packageTrunnion-mounted ball valves, 6 in, ASME Class 600
Valve tag and serial no.XV-3105-04; serial EX-BV-0871-04 (fictional)
Test certificatePTR-EX-0871-04 Rev 0
Test date2027-01-20
Test standard named in the orderAs stated in the PO (for example API 598 or ISO 5208), with its edition
Test procedureTP-BV-02 Rev B (fictional)
Checklist no.VTC-EX-3105-04
Date2027-01-22
Prepared byQuality engineer
Checked byTest engineer

Example checks: a ball valve certificate

Invented example checks for certificate PTR-EX-0871-04
ItemAreaCheckRequired by the orderOn the certificateResultRemarks
1IdentificationValve tag and serial number match the order and the nameplateTag XV-3105-04; nameplate list NL-EX-3105Tag XV-3105-04; serial EX-BV-0871-04OK
2IdentificationSize, pressure class and end connection are as the datasheet6 in, Class 600, raised face; datasheet DS-BV-3105 Rev C6 in, Class 600, RFOK
3StandardThe test standard is named with its edition, and is the one the order namesPS-VAL-001 9.1; TP-BV-02 Rev BStandard named; no edition or yearQueryAdd the edition the order names.
4TestsShell test: medium, pressure, duration and result recordedTP-BV-02 5.1: water, 154 bar (TP-BV-02 value, invented order), for the duration in 5.1Water, 154 bar, duration recorded and as TP-BV-02 5.1; no visible leakageOK
5TestsBackseat test, where the valve has a backseat and the order requires the testNot required: a ball valve has no backseatNot listedNot applicable
6TestsHigh-pressure closure test: pressure, duration and result recorded for each seat or directionTP-BV-02 5.3: water, 113 bar (TP-BV-02 value, invented order), each seatSeat A: 113 bar, result recorded. Seat B: no entryFailSeat B result missing. Find the bench record or retest before shipment.
7TestsLow-pressure closure test: pressure, duration and result recorded for each seat or directionTP-BV-02 5.4: air, 6 bar (TP-BV-02 value, invented order), each seatAir, 6 bar, both seats; duration and result recordedOK
8TestsAny further test the order adds is on the certificate or on a report it namesPS-VAL-001 9.4: operating torque checkRefers to functional test report FTR-EX-0871OK
9MediumThe test medium is stated and meets any limit the order sets on itPS-VAL-001 9.3: water quality limit; TP-BV-02 section 4Water; quality not statedQueryAttach the water analysis the specification asks for.
10AcceptanceThe certificate states the leakage acceptance applied and where it comes fromThe rate or class in the test standard the order names; PS-VAL-001 9.2Result given as Pass onlyQueryState the acceptance applied and the standard clause or procedure section it comes from.
11GaugesThe ID of each gauge and recorder used is on the certificateTP-BV-02 section 5PG-EX-114, PG-EX-115, PG-EX-131; recorder PR-EX-021OK
12GaugesEach gauge's calibration was valid on the test datePS-VAL-001 9.2; calibration checklist CALC-EX-3105PG-EX-131 due 2027-01-15; test date 2027-01-20FailLow-pressure test gauge was out of calibration. NCR raised; see the calibration checklist.
13WitnessWitnessed tests are signed by the witness, or a written waiver is attachedITP-BV-01: customer witness point for the pressure testsSigned by test operator and quality control; no customer signature or waiverQueryGet the inspector's signature or attach the waiver.
14DeviationsAgreed deviations or concessions that affect the pressure test are referencedAgreed deviation list TDL-EX-2291 Rev BNone applies to the pressure test; stated on the certificateOK
15CertificateThe certificate carries a number, revision, date and the signatures the procedure requiresTP-BV-02 section 7PTR-EX-0871-04 Rev 0, dated 2027-01-20, signedOK

The pressures shown are the values in an invented order's test procedure (TP-BV-02) and are labelled that way. They are not presented as the requirements of API 598, ISO 5208 or any other standard. Every example value is invented: the project, customer, bidders, purchase order, prices and every document, certificate, serial and report number do not exist. Standards are named but not quoted.

Columns and what to write

ColumnWhat to write
ItemRunning number.
AreaIdentification, Standard, Tests, Medium, Acceptance, Gauges, Witness, Deviations or Certificate.
CheckWhat to confirm on the pressure test certificate.
Required by the orderWhat the purchase order, datasheet, specification or approved test procedure asks for, with the clause. Pressures and durations go here as your procedure states them.
On the certificateWhat the certificate actually records: the test, medium, pressure, duration and result, as written.
ResultOK, Query, Fail or Not applicable (drop-down). Fail rows turn red; Query rows amber.
RemarksWhat is wrong or missing, and the action before shipment.

How to review a certificate with it

  1. Fill in the header block: the valve tag and serial number, the certificate number, the test date, and the test standard and procedure the order names.
  2. Check identification first: tag, serial number, size, class and end connection against the datasheet and the nameplate.
  3. List the tests the order requires in the Required by the order column, from the purchase order, the specification and your approved test procedure. Which tests apply to a valve type and size comes from the test standard; check the edition the order names.
  4. For each test, copy what the certificate records: medium, pressure, duration and result, for each seat or direction where that applies.
  5. Write pressures and durations as your approved procedure states them. The checklist compares the certificate with the procedure; it does not supply values.
  6. Check the test medium, and that the certificate says which leakage acceptance was applied.
  7. Check gauge IDs and calibration validity on the test date, the witness signature or waiver, and any deviation that affects the test.
  8. Set the result for each row. Fail rows turn red and Query rows amber. Close each one before the valve ships.

Checking test records against the order across a whole batch

One certificate is quick to read. Forty for a single shipment are not. In OdysseyGPT's Inspection & Testing module, Inspection Readiness Check (beta) reads the ITP, the test procedure and the reports on file and lists what is missing or does not match before an inspection or release. Calibration Validity Check (beta) compares each gauge's certificate with the test date. Every finding quotes its page, and a quality engineer decides what happens next. Tools marked beta are open on request, and we onboard each team ourselves.

Want us to run the check for you?

Send your ITP and the customer's quality requirements. We send back what is covered, what is missing and what still needs evidence before the FAT.

Get the free ITP and FAT readiness check

New templates by email (optional)

Your download does not depend on this.

We use your email only for this. See our privacy policy.

Frequently asked questions

What is a valve test certificate?

The manufacturer's signed record of the pressure tests made on a valve: which tests, with what medium, at what pressure, for how long and with what result. It names the valve by tag or serial number and the standard the tests were made to.

Which tests should a valve pressure test certificate show?

Those the order and its test standard require for that valve type, size and class, usually a shell test and one or more closure tests, plus a backseat test where the valve has one and the order calls for it. Check the edition of the standard the order names.

Why does the checklist not give test pressures or durations?

Because they depend on the standard, its edition, the valve's rating and anything the customer added. They belong in your approved test procedure. The checklist compares the certificate with that procedure.

Is a valve test certificate the same as a material certificate?

No. A material certificate reports the chemistry and mechanical properties of the body, bonnet or trim material. The pressure test certificate reports how the assembled valve behaved under test. A shipment normally needs both.

What if the certificate does not name the edition of the test standard?

Treat it as a query. Requirements change between editions, and the order usually fixes one. Ask the test department to add the edition they worked to and confirm it matches the order.

References

Creative Commons Attribution 4.0 International

Creative Commons

Visit source

Related Pages