Download the valve test certificate checklist
XLSX
Valve test certificate checklist (Excel)
Header block, 7 columns, a result drop-down, Fail rows in red and Query rows in amber, frozen header row, filters and a How to use sheet.
CSV
Valve test certificate checklist (CSV)
The example rows as plain CSV (UTF-8), for Google Sheets or any other tool.
Both files are free under CC BY 4.0, with no form to fill in. The XLSX opens in Excel, Google Sheets, LibreOffice and Numbers. The CSV carries the table only; the header block is in the XLSX.
Why review the certificate before the valve ships
The pressure test certificate is the document a receiving inspector opens first. If a seat test has no entry or the gauge was out of date, the valve is quarantined at the customer's site and the argument starts there. Ten minutes with this checklist, after testing and before the certificate is signed, moves that argument back into your own test bay where it can still be fixed.
- Quality engineers at valve manufacturers, on each certificate or on a sample the quality plan sets.
- Stockists and modification shops, who retest valves and issue their own certificates.
- Buyers' inspectors, who can use the same rows at goods-in.
Which tests a valve needs, and at what pressure and for how long, depends on the valve type, size and class and on the test standard the order names, commonly API 598 or ISO 5208. The two are not interchangeable. Check the governing standard or contract. See also valve manufacturers.
Header block
| Field | Example |
|---|---|
| Project | Example Gas Compression Station, Phase 2 (fictional) |
| Customer | Example EPC Contractor Ltd (fictional) |
| Purchase order | PO-EX-3105 (fictional) |
| Equipment / package | Trunnion-mounted ball valves, 6 in, ASME Class 600 |
| Valve tag and serial no. | XV-3105-04; serial EX-BV-0871-04 (fictional) |
| Test certificate | PTR-EX-0871-04 Rev 0 |
| Test date | 2027-01-20 |
| Test standard named in the order | As stated in the PO (for example API 598 or ISO 5208), with its edition |
| Test procedure | TP-BV-02 Rev B (fictional) |
| Checklist no. | VTC-EX-3105-04 |
| Date | 2027-01-22 |
| Prepared by | Quality engineer |
| Checked by | Test engineer |
Example checks: a ball valve certificate
| Item | Area | Check | Required by the order | On the certificate | Result | Remarks |
|---|---|---|---|---|---|---|
| 1 | Identification | Valve tag and serial number match the order and the nameplate | Tag XV-3105-04; nameplate list NL-EX-3105 | Tag XV-3105-04; serial EX-BV-0871-04 | OK | |
| 2 | Identification | Size, pressure class and end connection are as the datasheet | 6 in, Class 600, raised face; datasheet DS-BV-3105 Rev C | 6 in, Class 600, RF | OK | |
| 3 | Standard | The test standard is named with its edition, and is the one the order names | PS-VAL-001 9.1; TP-BV-02 Rev B | Standard named; no edition or year | Query | Add the edition the order names. |
| 4 | Tests | Shell test: medium, pressure, duration and result recorded | TP-BV-02 5.1: water, 154 bar (TP-BV-02 value, invented order), for the duration in 5.1 | Water, 154 bar, duration recorded and as TP-BV-02 5.1; no visible leakage | OK | |
| 5 | Tests | Backseat test, where the valve has a backseat and the order requires the test | Not required: a ball valve has no backseat | Not listed | Not applicable | |
| 6 | Tests | High-pressure closure test: pressure, duration and result recorded for each seat or direction | TP-BV-02 5.3: water, 113 bar (TP-BV-02 value, invented order), each seat | Seat A: 113 bar, result recorded. Seat B: no entry | Fail | Seat B result missing. Find the bench record or retest before shipment. |
| 7 | Tests | Low-pressure closure test: pressure, duration and result recorded for each seat or direction | TP-BV-02 5.4: air, 6 bar (TP-BV-02 value, invented order), each seat | Air, 6 bar, both seats; duration and result recorded | OK | |
| 8 | Tests | Any further test the order adds is on the certificate or on a report it names | PS-VAL-001 9.4: operating torque check | Refers to functional test report FTR-EX-0871 | OK | |
| 9 | Medium | The test medium is stated and meets any limit the order sets on it | PS-VAL-001 9.3: water quality limit; TP-BV-02 section 4 | Water; quality not stated | Query | Attach the water analysis the specification asks for. |
| 10 | Acceptance | The certificate states the leakage acceptance applied and where it comes from | The rate or class in the test standard the order names; PS-VAL-001 9.2 | Result given as Pass only | Query | State the acceptance applied and the standard clause or procedure section it comes from. |
| 11 | Gauges | The ID of each gauge and recorder used is on the certificate | TP-BV-02 section 5 | PG-EX-114, PG-EX-115, PG-EX-131; recorder PR-EX-021 | OK | |
| 12 | Gauges | Each gauge's calibration was valid on the test date | PS-VAL-001 9.2; calibration checklist CALC-EX-3105 | PG-EX-131 due 2027-01-15; test date 2027-01-20 | Fail | Low-pressure test gauge was out of calibration. NCR raised; see the calibration checklist. |
| 13 | Witness | Witnessed tests are signed by the witness, or a written waiver is attached | ITP-BV-01: customer witness point for the pressure tests | Signed by test operator and quality control; no customer signature or waiver | Query | Get the inspector's signature or attach the waiver. |
| 14 | Deviations | Agreed deviations or concessions that affect the pressure test are referenced | Agreed deviation list TDL-EX-2291 Rev B | None applies to the pressure test; stated on the certificate | OK | |
| 15 | Certificate | The certificate carries a number, revision, date and the signatures the procedure requires | TP-BV-02 section 7 | PTR-EX-0871-04 Rev 0, dated 2027-01-20, signed | OK |
The pressures shown are the values in an invented order's test procedure (TP-BV-02) and are labelled that way. They are not presented as the requirements of API 598, ISO 5208 or any other standard. Every example value is invented: the project, customer, bidders, purchase order, prices and every document, certificate, serial and report number do not exist. Standards are named but not quoted.
Columns and what to write
| Column | What to write |
|---|---|
| Item | Running number. |
| Area | Identification, Standard, Tests, Medium, Acceptance, Gauges, Witness, Deviations or Certificate. |
| Check | What to confirm on the pressure test certificate. |
| Required by the order | What the purchase order, datasheet, specification or approved test procedure asks for, with the clause. Pressures and durations go here as your procedure states them. |
| On the certificate | What the certificate actually records: the test, medium, pressure, duration and result, as written. |
| Result | OK, Query, Fail or Not applicable (drop-down). Fail rows turn red; Query rows amber. |
| Remarks | What is wrong or missing, and the action before shipment. |
How to review a certificate with it
- Fill in the header block: the valve tag and serial number, the certificate number, the test date, and the test standard and procedure the order names.
- Check identification first: tag, serial number, size, class and end connection against the datasheet and the nameplate.
- List the tests the order requires in the Required by the order column, from the purchase order, the specification and your approved test procedure. Which tests apply to a valve type and size comes from the test standard; check the edition the order names.
- For each test, copy what the certificate records: medium, pressure, duration and result, for each seat or direction where that applies.
- Write pressures and durations as your approved procedure states them. The checklist compares the certificate with the procedure; it does not supply values.
- Check the test medium, and that the certificate says which leakage acceptance was applied.
- Check gauge IDs and calibration validity on the test date, the witness signature or waiver, and any deviation that affects the test.
- Set the result for each row. Fail rows turn red and Query rows amber. Close each one before the valve ships.
Checking test records against the order across a whole batch
One certificate is quick to read. Forty for a single shipment are not. In OdysseyGPT's Inspection & Testing module, Inspection Readiness Check (beta) reads the ITP, the test procedure and the reports on file and lists what is missing or does not match before an inspection or release. Calibration Validity Check (beta) compares each gauge's certificate with the test date. Every finding quotes its page, and a quality engineer decides what happens next. Tools marked beta are open on request, and we onboard each team ourselves.
Want us to run the check for you?
Send your ITP and the customer's quality requirements. We send back what is covered, what is missing and what still needs evidence before the FAT.