What is API 598?
API 598, Valve Inspection and Testing, sets the inspection, examination and pressure test requirements for gate, globe, plug, ball, check and butterfly valves, with metal, resilient or other non-metallic seats. It is a test standard, not a product standard: it says how a finished valve is inspected and tested, not how it is designed. Product standards and purchase orders call it up. For how it fits with the product standards, see the API valve standards hub.
The pressure tests in API 598
| Test | What it proves | How it is usually summarised |
|---|---|---|
| Shell test | The pressure-containing body, bonnet and joints do not leak | Liquid at about 1.5 times the valve's pressure rating at 38 °C (100 °F), valve partly open, no visible leakage through the shell |
| Backseat test | The stem backseat seals, on valves that have one | At about 1.1 times the 38 °C rating, with the packing gland loose or packing not fitted |
| Low-pressure closure test | The seats seal against gas at low pressure | Air or inert gas at roughly 4 to 7 bar (60 to 100 psig) |
| High-pressure closure test | The seats seal against full differential pressure | Liquid at about 1.1 times the 38 °C rating |
The standard has a table that says which of these tests are required and which are optional for each valve type, size range and pressure class. For some valves the high-pressure closure test is optional unless the purchaser asks for it. Minimum test durations rise with valve size. Read the tables in the edition the order names; do not rely on a summary, including this one.
Seat leakage under API 598
No visible leakage is allowed through the shell. For the closure tests, resilient-seated (soft-seated) valves must show no visible leakage for the test duration. Metal-seated valves are allowed a small leakage rate that depends on valve size, given in the standard as drops of liquid or bubbles of gas per minute. Check valves have their own, higher allowance. "Zero leakage" on a metal-seated valve is therefore a requirement beyond API 598, and it should be treated as a deviation or priced.
API 598 compared with API 6D, ISO 5208 and FCI 70-2
| Standard | Used for | How leakage is expressed |
|---|---|---|
| API 598 | General refinery and process valves built to standards such as API 600, 602 and 609 | No visible leakage for soft seats; a size-based allowance for metal seats |
| API 6D | Valves supplied to API 6D, which sets its own pressure tests | Set in the specification itself, which refers to ISO 5208 leakage rates |
| ISO 5208 | Industrial valves generally, widely used outside North America | Leakage rates lettered A to G, with rate A meaning no visible leakage |
| FCI 70-2 (ANSI/FCI 70-2) | Control valves | Leakage classes I to VI |
A tender that names API 598 for a valve built to API 6D, or an ISO 5208 rate for a valve tested to API 598, is asking for two things at once. Raise it as a clarification before you quote, and record the answer on the deviation list.
What to check in a tender against API 598
| Check | Why it matters |
|---|---|
| Test standard and edition named in the requisition, datasheet and specification | Documents in one package often name different standards or editions |
| Which closure tests are required: low pressure, high pressure or both | An optional test made mandatory adds test time on every valve |
| Test durations longer than the standard's minimums | Owner specifications often extend them, which changes test bay capacity |
| Seat leakage acceptance, especially "zero leakage" on metal seats | Tighter than API 598 and may need lapping, a different seat or a deviation |
| Test medium: water quality, chloride limit for stainless steels, corrosion inhibitor, gas type | Wrong test water can stain or attack stainless steel |
| Extra tests: fugitive emission, cryogenic, high-pressure gas, fire test evidence | These are separate standards with their own cost and lead time |
| Witness and hold points for the customer or a third-party inspector | Notification periods and inspector availability set the delivery date |
| Test certificates and records required, and their format | They become part of the manufacturing record book |
| Gauge and recorder calibration requirements | Certificates must be valid on the day of the test |
OdysseyGPT's Document Review checks a customer's specification package against your own datasheets and standard test procedures and drafts the compliance matrix and deviation list, each row quoting its source. After the order, the ITP Validator (beta) checks the inspection and test plan against the customer's requirements, and the FAT Readiness Check (beta) checks the procedure, calibration and open items before the test.