OdysseyGPT

Glossary term

Fire-Safe Test

A type test in which a pressurised valve is exposed to fire and then checked for external and seat leakage, to show the design still contains pressure after its soft parts have burned.

Last reviewed by the OdysseyGPT team

What it is

A fire-safe test is a type test for valves. A pressurised sample valve is exposed to fire for a set period, then cooled and operated, and its external and seat leakage are measured against the limits of a standard such as API 607, API 6FA or ISO 10497. A pass qualifies a stated range of the design.

Key Takeaways

  • It is a type test on sample valves, not a production test.
  • The certificate covers a stated range of sizes, classes and materials.
  • API 607, API 6FA and ISO 10497 are the standards most often named.
  • Check the edition the tender names against the edition on your certificate.

Why it matters

A fire-safe test, more exactly a fire type test, shows how a valve design behaves in a fire. A sample valve is closed, filled with water, pressurised and surrounded by flames for a set period. Leakage through the seat and to the outside is measured during the burn. The valve is then cooled and checked again, and it is operated to show that it can still be moved. Soft seats and seals are expected to be damaged; the test shows whether the secondary metal seating and the stem and body seals still limit leakage to what the standard allows. It is a type test, made on sample valves and not on each valve supplied. The qualification is then extended to other sizes, pressure classes and materials of the same design by rules in the standard, so a certificate covers a stated range and no more. Three standards are met most often. API 607 covers quarter-turn valves and valves with non-metallic seats. API 6FA is the fire test associated with valves built to API 6A and API 6D. ISO 10497 is the international standard for fire type-testing of valves. Their procedures and acceptance limits have changed between editions, so the edition matters. "Fire-safe" is the everyday term; the standards speak of fire-tested or fire type-tested valves.

How OdysseyGPT uses it

OdysseyGPT does not test valves and does not issue or validate fire test certificates. Document Review finds the fire test requirement in the customer's specification and datasheets, including the standard and edition named, and checks it against the documents you offer. It reports a mismatch, such as a different standard or an edition older than the one required, with a quote from each side. Whether a certificate's range covers the valve offered is for your engineer to confirm.

Evaluation questions

What should a bid engineer check on a fire test certificate?

The standard and edition, the valve design and seat and seal materials tested, the sizes and classes the qualification extends to, the test laboratory or witness, and whether the valve offered falls inside that range.

How do fire test requirements appear in a tender?

Usually as a line on the valve datasheet or a clause in the valve specification naming the standard, sometimes with an edition and a requirement for third-party witnessing. Certificates are often requested with the offer.

Does OdysseyGPT confirm that a valve is fire-safe?

No. It reads the requirement and the documents you upload and reports where they differ, with quotes. It does not judge the test or the design.

Frequently asked questions

What is a fire-safe test for a valve?

A type test in which a pressurised sample valve is exposed to flames and then checked for leakage through the seat and to the outside, during the fire and after cooling. It shows the design still contains pressure.

Which standards cover valve fire testing?

API 607 for quarter-turn valves and valves with non-metallic seats, API 6FA for valves built to API 6A and API 6D, and ISO 10497 for fire type-testing of valves. The tender should name the standard and edition.

Is every valve fire tested?

No. It is a type test on sample valves, and it destroys the soft parts. The result qualifies a range of sizes, classes and materials of the same design under the standard's rules.

What is the difference between fire-safe and fire-tested?

Fire-safe is the everyday term and is sometimes used loosely for a design feature. Fire-tested means the design has passed a named fire test standard, with a certificate. A tender normally wants the second.

References

API Standard 607: Fire Test for Quarter-turn Valves and Valves Equipped with Nonmetallic Seats