OdysseyGPT

Standards explainer

ISO 15848-1 fugitive-emission requirements: what to check in a tender

How ISO 15848-1 classifies valve stem and body-seal leakage, how it differs from ISO 15848-2 and the API tests, and the low-emission clauses that most often become deviations.

By Ademola Afolabi, Founder, New Odyssey Ltd · Last reviewed:

The short answer

ISO 15848-1 is a type test that qualifies a valve design for low fugitive emissions. It grades the design by tightness class, endurance class (number of mechanical cycles) and temperature class. When a tender asks for ISO 15848-1, check that your qualified design, test medium and all three classes match, or declare a deviation.

Key Takeaways

  • ISO 15848-1 qualifies a design by type test; ISO 15848-2 is a production test on delivered valves.
  • A requirement has three parts: tightness class, endurance class and temperature class. Check all three.
  • Check the test medium (helium or methane) and whether your qualification extends to the size and class offered.
  • API 622, API 624 and API 641 are separate tests; one does not automatically satisfy another.

What is a valve fugitive emission test?

Fugitive emissions are small, unintended leaks of process fluid to the atmosphere, mostly through the stem seal and body joints of a valve. A fugitive emission test measures that leakage under set conditions: pressure, temperature and a number of open-close cycles. It shows that a seal design stays tight over its working life, not just when new.

How ISO 15848-1 classifies a valve

The three parts of an ISO 15848-1 classification (own summary)
PartWhat it describesHow it is written
Tightness classMaximum measured stem-seal leakage, from tightest to least tightA, B or C with a suffix for the test medium: AH, BH, CH for helium, AM, BM, CM for methane
Endurance classMechanical and thermal cycles completed during the test, with separate classes for on-off and control valvesCO1, CO2, CO3 for on-off valves (CO1 is 205 full strokes and two thermal cycles; CO3 totals 2,500 strokes); CC1, CC2, CC3 for control valves
Temperature classTest temperature the qualification coversOne of six classes from −196 °C to +400 °C, written for example t(RT) for room temperature

A full requirement reads something like "ISO 15848-1, class BH, CO1, t(RT)". Manufacturers' certificates often add the stem-seal adjustment and pressure class, for example ISO 15848-BH-CO3-SSA0-t(RT) (A-T Controls; Valve World Americas). Each part can be a separate deviation: a tighter class, more cycles or a wider temperature range than your qualification covers. These summaries come from published manufacturer and test-lab documents; check leak-rate limits in the current edition of the standard itself.

ISO 15848-1 vs ISO 15848-2

ISO 15848-1ISO 15848-2
PurposeType test: qualifies a designProduction test: checks delivered valves
WhenOnce per design family, before supplyOn production valves whose design has already passed the Part 1 type test
EnduranceMechanical and thermal cycles set by the endurance and temperature classesNot an endurance qualification
What to offerQualification report covering the offered size and classTest on the order, often witnessed

How the API fugitive-emission tests relate

Tenders in oil and gas often name an API test instead of, or as well as, ISO 15848-1. API 622 type-tests the packing set itself in a standard fixture. API 624 type-tests rising-stem valves fitted with packing already tested to API 622, with a 100 ppmv limit. API 641 type-tests quarter-turn valves with methane and a 100 ppmv limit (Chesterton; Valve Magazine). They differ from ISO 15848-1 in medium, cycles and acceptance criteria, so treat a request for one when you hold another as a clarification or a deviation, not as equivalent.

What to check in a tender

Fugitive-emission checks before you answer a low-emission clause
CheckQuestion to answerTypical deviation
Standard namedISO 15848-1, ISO 15848-2, API 622, 624 or 641, or an owner standard?Different standard offered
Tightness classIs your qualified class at least as tight?Class BH required, AH or CH held
Endurance classDoes your qualification cover the cycles asked?CO1 held where CO2 is asked
Temperature classDoes the qualified range cover the design temperatures?Room-temperature qualification only
Test mediumHelium or methane?Medium differs from the spec
Qualification rangeDoes the type test extend to this size, class and stem seal?Qualified on a different size or packing
Production testingIs ISO 15848-2 or a witnessed test also required?Not priced
EvidenceWhich report or certificate must be submitted, and by when?Report not listed in the VDRL

Write each gap as a row in your technical deviation list; the worked valve example there includes an ISO 15848-1 clarification. Use the datasheet vs specification checklist and free templates for the rest of the datasheet, and see API 6D and the API valve standards hub for the product standards these clauses sit beside.

Low-emission clauses are spread across project specs, owner standards and datasheets, so they are easy to miss. OdysseyGPT lists each one with its clause and page for an engineer to check against your qualification records; see OdysseyGPT for manufacturing.

Buyer questions

20 questions bid engineers, proposal engineers and buyers ask. Last reviewed:

What does ISO 15848-1 cover?

ISO 15848-1 sets out how to measure, test and qualify industrial valves for fugitive emissions. It covers leakage through the stem or shaft seal and through body joints, on both isolating and control valves. A design that passes is given a class for tightness, endurance and temperature. Buyers use that class to specify low-emission valves in a tender.

Why do valve tenders ask for ISO 15848-1?

Operators want to limit leaks of process fluid to the air, for safety, environmental and regulatory reasons. ISO 15848-1 gives them a common way to specify and compare stem-seal tightness across suppliers. Instead of a vague low-emission request, the tender can name a tightness, endurance and temperature class that your qualification either meets or does not.

Is ISO 15848-1 required by law?

Not as such. ISO 15848-1 is a voluntary standard. It becomes a requirement when an owner specification or purchase order calls it up, often to help the plant meet emission rules. So the contract decides what you must meet. Read the specification for the exact classes, test medium and evidence asked for, and treat each as a contract requirement.

What is the difference between ISO 15848-1 tightness classes A, B and C?

Class A is the tightest stem-seal leakage class, class B is next and class C allows the most leakage. Class A is often associated with bellows-sealed designs, while many packed valves are qualified to B or C. The letter is followed by H or M for helium or methane. Check the exact limits in the edition the tender names.

Should an ISO 15848-1 test use helium or methane?

Use the medium the tender names, because a class achieved with one medium does not convert directly to the other. Helium classes end in H, such as BH, and methane classes end in M, such as BM. The two are measured in different ways. If the tender asks for methane and you hold a helium qualification, raise a clarification or declare a deviation.

What do the CO and CC endurance classes mean in ISO 15848-1?

Endurance classes describe how many mechanical cycles, plus thermal cycles, the valve completed during the type test while staying within its tightness class. CO classes are for on-off valves and CC classes for control valves. A higher number means more cycles. Your qualification must reach at least the class the tender asks for, or it is a deviation.

What does the temperature class mean in ISO 15848-1?

The temperature class shows the test temperature the qualification covers, from cryogenic to high temperature, or room temperature only. A valve qualified at room temperature does not cover a hot or cold service on its own. Compare the temperature class on your certificate with the design temperatures on the datasheet. A gap is a deviation to declare.

Does ISO 15848-1 cover body seals as well as the stem?

Yes. The tightness class is based on stem or shaft seal leakage, but the test also checks leakage from body seals, such as the body-bonnet joint. Some tenders set separate requirements for body joints. Read the clause closely and confirm your test report shows the body seal results the tender asks for, not only the stem result.

What does SSA mean on an ISO 15848-1 certificate?

SSA stands for stem seal adjustment. It records how many times the stem seal, such as the packing, was adjusted during the type test. SSA0 means no adjustment was made. Some buyers ask for zero adjustments, because an adjustment in the test suggests the seal may need retightening in service. Check whether the tender sets a limit.

What are common ISO 15848-1 deviations in valve tenders?

The most common are a tightness class that is less tight than asked, too few endurance cycles, and a room-temperature qualification against a hot or cold service. A different test medium comes up often too. So does a type test on a different size, class or packing from the valve offered. Record each one in a technical deviation list.

What evidence do EPCs ask for to prove ISO 15848-1 compliance?

Usually the type-test report or certificate for the qualified design, showing the classes, test medium, and the size and pressure class tested. Many owners want the test witnessed or certified by an independent third party. Some ask for a statement that the offered valve falls within the qualification range. The vendor data requirements list says when each document is due.

When does a tender ask for ISO 15848-2 as well as Part 1?

When the buyer wants production valves checked, not just the design. ISO 15848-2 is a production acceptance test on delivered valves whose design is already qualified to Part 1. Tenders may ask for it on a sample or on every valve, and sometimes witnessed. It adds time and cost, so price it and confirm the sampling rate.

Is ISO 15848-1 the same as API 624?

No. API 624 is a type test for rising-stem valves fitted with packing already tested to API 622. ISO 15848-1 covers both rising-stem and quarter-turn valves and grades them by class. The two differ in test medium, cycles and acceptance criteria. If the tender asks for one and you hold the other, treat it as a clarification or a deviation.

Does ISO 15848-1 apply to control valves?

Yes. ISO 15848-1 has separate endurance classes for control valves, written CC1 to CC3, because control valves move much more often than on-off valves. A tender for control valves should name a CC class. If it names a CO class for a control valve, or no class at all, raise a clarification. See IEC 60534 control valves.

Does a change of packing or stem seal need a new ISO 15848-1 test?

Usually, yes. The qualification belongs to the tested design, including the stem seal arrangement and materials. A different packing, seal or stem design is generally outside the qualification and may need a new type test. Check the extension rules in the standard and ask the buyer before you rely on an older test for a changed design.

What should I do if a tender just says low-emission valves?

Raise a clarification. Ask which standard applies, such as ISO 15848-1, API 624 or API 641, and which tightness, endurance and temperature classes are needed. Without that, you cannot show compliance and the buyer cannot compare offers. State the qualification you hold in your offer, so the evaluation is made against a clear basis.

Should I price an ISO 15848-1 type test into my bid?

Only if you do not already hold a qualification that covers the offered valve. A new type test takes time on a test rig, often with a third-party witness, so it affects both cost and delivery. If you need one, say so in the offer and show the cost and time. If you hold one, list the report as evidence.

How do I check a valve datasheet against ISO 15848-1 requirements?

Find every low-emission clause in the package first, because they sit in owner standards, project specifications and datasheets. Then compare each with your qualification record: standard, tightness class, medium, endurance class, temperature class, size, class and stem seal. Mark each complies, deviates or needs clarification. The datasheet checklist covers the rest.

How does OdysseyGPT check ISO 15848-1 requirements in a tender?

OdysseyGPT reads the whole tender package and lists each fugitive-emission requirement with a quote and page from the source. It checks each one against the documents you supply, such as your datasheets and qualification reports, and gives it a status. You export an editable compliance matrix and a deviations and clarifications list for an engineer to review.

Can OdysseyGPT tell me if my valve passes ISO 15848-1?

No. Only a type test can qualify a valve. OdysseyGPT does not run tests, ship copies of ISO 15848-1 or certify compliance. It compares the tender's requirements with the evidence in your own documents and shows where they match, differ or need a clarification, with the source quoted. Your engineers decide every open item.

Frequently asked questions

What does ISO 15848-1 class BH CO1 mean?

It describes a qualification: tightness class B measured with helium (BH), and endurance class CO1, the lowest cycle class for on-off valves. A temperature class is normally stated as well.

Is ISO 15848-1 a production test?

No. ISO 15848-1 is a type test that qualifies a design. ISO 15848-2 covers production testing of delivered valves.

Does API 641 replace ISO 15848-1?

No. API 641 is a separate fugitive-emission type test for quarter-turn valves. A tender that asks for one does not automatically accept the other.

Does one ISO 15848-1 test cover every valve size?

Not necessarily. The standard has rules for extending a qualification to other sizes and classes. Check that your report covers the valve you are offering.

References

ISO 15848-1: Industrial valves. Measurement, test and qualification procedures for fugitive emissions. Part 1

ISO

Buy the current edition from iso.org or your national standards body.

ISO 15848-2: Production acceptance test of valves

ISO (listing via Genorma)

Visit source

Fugitive emission standards

A-T Controls

Visit source

Reduction of fugitive emissions: valve testing according to ISO 15848-1

Valve World Americas

Visit source

Fugitive emissions API standards for valves

Chesterton

Visit source

API Standard 641, API Standard 624 and API Standard 622

American Petroleum Institute

Related Pages