Unintended leaks of gas or vapour to the atmosphere from equipment such as valve stems, flanged joints and pump or compressor seals.

Last reviewed by the OdysseyGPT team

What it is

Fugitive emissions are unintended leaks of gas or vapour to the atmosphere from equipment, mainly through valve stem packings, flanged joints and rotating shaft seals. Plant operators find them with leak detection and repair programmes. Tenders control them by naming qualification tests, such as ISO 15848-1 or API 624 and API 641 for valves.

Key Takeaways

  • The main sources are valve stems, joints and shaft seals.
  • Operators screen for leaks; makers qualify designs by type test.
  • ISO 15848-1, API 622, API 624 and API 641 are the valve standards most often named.
  • A type test report covers a stated range of the design, so check the valve offered is inside it.

Why it matters

Fugitive emissions are leaks that escape from pressurised equipment through seals and joints instead of through a vent or stack. On a process plant the main sources are valve stem packings, flanged and threaded joints, and the shaft seals of pumps and compressors. Each leak is small, but a plant has many thousands of such points, and the escaping fluid may be a volatile organic compound, a toxic gas or methane. Plant operators therefore run leak detection and repair programmes, in which components are screened with a portable analyser. In the United States the usual screening method is EPA Method 21, which reads a concentration near the leak point and does not measure a mass flow. Equipment makers meet the subject through qualification tests named in tenders. For valves, ISO 15848-1 is a type test that classifies a design by tightness, endurance and temperature, and ISO 15848-2 is a production acceptance test. API 622 tests valve stem packing on its own. API 624 is a type test for rising-stem valves fitted with graphite packing, and API 641 is the matching type test for quarter-turn valves. For pumps and compressors the subject is handled through the seal standards. A tender should name the standard, the class or limit and the evidence wanted.

How OdysseyGPT uses it

OdysseyGPT does not measure emissions and does not run or certify type tests. Document Review reads the customer's specification package for fugitive emission requirements, such as the test standard, the class and whether a production test is wanted, and compares them with your datasheets and qualification documents. Where the two differ it reports the finding with a quote from each, as a draft row for the deviation list. Your engineers check that a type test report covers the valve offered.

Evaluation questions

What should a bid engineer check about fugitive emissions in a tender?

The standard and edition, the class or leakage limit, the test fluid where the standard gives a choice, whether production testing is required and on how many valves, and whether your type test report covers the size, class and packing offered.

What does "low-emission valve" mean in a specification?

It has no fixed meaning on its own. The specification should say which test standard and which class or limit define it. If it does not, raise a clarification before quoting.

Does OdysseyGPT measure or certify fugitive emissions?

No. It reads the requirement in the customer's documents and compares it with the documents you offer, quoting both. Testing and certification stay with the test laboratory and your engineers.

Frequently asked questions

What are fugitive emissions?

Unintended leaks of gas or vapour from equipment to the atmosphere, mainly through valve stem packings, flanged joints and the shaft seals of pumps and compressors.

Which standards cover fugitive emissions from valves?

ISO 15848-1 (type testing) and ISO 15848-2 (production acceptance testing), API 622 for stem packing, API 624 for rising-stem valves with graphite packing and API 641 for quarter-turn valves.

How are fugitive emissions measured?

On a plant, components are screened with a portable analyser, in the United States usually to EPA Method 21, which reads a concentration near the leak. Laboratory type tests use the methods their own standards set.

What is the difference between a fugitive emission type test and a production test?

A type test qualifies a valve design by testing sample valves through mechanical and thermal cycles. A production test checks valves from the order itself, usually a sample, at ambient conditions.

References

Fugitive emissions standards for valves

Valve Magazine

Visit source

API 624 works to reduce valve fugitive emissions

Pumps & Systems

Visit source

The valve's role in fugitive emissions compliance

Processing Magazine

Visit source

ISO 15848-1 and ISO 15848-2: Industrial valves — Measurement, test and qualification procedures for fugitive emissions

ISO