Calibration certificates for test reports: when a certificate supports a test

The checks inspectors make on the gauges and instruments named in your pressure, performance and dimensional test reports, and how to pass them before the witness test.

By Ademola Afolabi, Founder, New Odyssey Ltd · Last reviewed:

The short answer

A calibration certificate supports a test only if it is for the exact instrument used (by serial or ID), was valid on the test date, covers the range used and traces to a national standard. Inspectors reject test reports where any of these fail, so check them before the witness test, not at MRB stage.

Key Takeaways

  • Match the instrument on the test report to the certificate by serial number or asset ID, not by type.
  • Compare the calibration due date with the test date, not with today.
  • The calibrated range must cover the values you measured.
  • A certificate should show traceability to national or international standards.

What a calibration certificate is

A calibration certificate records that an instrument, such as a pressure gauge, transducer, thermometer or torque wrench, was compared against a reference standard, and what was found. It is issued by a calibration laboratory or your own calibration function. On engineered-equipment orders, the test reports name the instruments used, and the certificates prove those readings can be trusted.

What a certificate should contain

  • The instrument's identity: maker, model, serial number or asset ID.
  • The calibration date, and often a due date or interval.
  • The points or range calibrated, the readings found and, where adjusted, the readings after adjustment.
  • The measurement uncertainty, on most laboratory certificates.
  • The reference standards used and their traceability to national or international standards.
  • The laboratory's name and, where it has one, its accreditation, for example to ISO/IEC 17025.
  • A signature or authorisation, and a certificate number.

Four checks against each test

The checks an inspector makes (own summary)
CheckWhat passesCommon failure
IdentityThe serial or asset ID on the test report matches the certificateReport says "gauge 0–400 bar" with no ID
DateThe test date falls inside the calibration validityCertificate expired a week before the test
RangeThe values measured sit inside the calibrated rangeTest at a pressure above the highest calibrated point
TraceabilityThe certificate traces to a national or international standardIn-house check with no traceable reference

Customer specifications can add more, such as an accredited laboratory, a maximum calibration interval or a gauge range rule. Read the order's quality clauses and the approved test procedure.

What ISO 9001 expects

ISO 9001, in its clause on monitoring and measuring resources, expects instruments used to verify product to be calibrated or verified at set intervals against standards traceable to national or international standards, identified so their status is clear, and protected from adjustments that would spoil the result. If an instrument is found out of calibration, you must check whether earlier results are still valid. Read the standard itself for the exact wording.

When an instrument is found out of calibration

List every test that used the instrument since its last good calibration. Assess whether the error could have changed a pass to a fail. Tell the customer where their tests are affected, and repeat tests where needed. Record it as a nonconformance. Finding this after shipment is far worse than before the witness test.

Check before the witness test

  1. List the instruments each test procedure needs, by ID.
  2. Check each certificate is in date on the planned test date, with a margin if the date might slip.
  3. Check the range suits the test values in the procedure.
  4. Put copies of the certificates with the test pack for the inspector.
  5. Write the instrument IDs on the test record sheet before the test starts.

This is part of factory acceptance test (FAT) preparation. The certificates then go into the calibration section of the manufacturing record book.

Doing it with OdysseyGPT

The Calibration Validity Check (beta) matches each instrument on your test reports to its calibration certificate by identity, then checks validity on the date of use, range and the traceability chain, and flags certificates about to expire. Every finding cites the report and the certificate. A quality engineer decides what to do with each one.

These tools are in beta

The Calibration Validity Check are in beta. You can request access, and we onboard each team ourselves. Every finding cites the page, sheet or cell it came from, and your engineers decide what to do with it.

Buyer questions

6 questions bid engineers, proposal engineers and buyers ask. Last reviewed:

How do I check a calibration certificate is valid for a test?

Make four checks. The serial number or asset ID on the test report matches the certificate. The test date falls inside the calibration validity. The values measured sit inside the calibrated range. The certificate traces to national or international standards. Then check anything extra the order asks for, such as an accredited laboratory or a maximum interval.

What should a calibration certificate contain?

The instrument's maker, model and serial number or ID; the calibration date and often the due date; the points calibrated with the readings found; the measurement uncertainty; the reference standards used and their traceability; the laboratory's name and any accreditation; and a certificate number with a signature or authorisation.

What does ISO 9001 say about calibration?

In short, ISO 9001 expects measuring instruments used to verify product to be calibrated or verified at set intervals against traceable standards, labelled so their status is clear, and protected from damage or adjustment. When one is found out of calibration, you must check whether earlier results are still valid and act. Read the standard for its exact wording.

What happens if a gauge was out of calibration during a test?

The result may not count. Inspectors can reject the test report, and the customer may ask for the test to be repeated and witnessed again. Internally, list every test that used the gauge since its last good calibration, assess the effect, and raise a nonconformance. That is why calibration is checked before the witness test.

What does traceable calibration mean?

It means the instrument was compared against a reference whose own calibration links, through an unbroken chain of comparisons, to a national or international measurement standard, with the uncertainty stated at each step. National metrology institutes, such as NIST in the US or NPL in the UK, sit at the top of the chain.

Is there software that checks calibration certificates against test reports?

Calibration management software tracks your instruments and due dates. OdysseyGPT's Calibration Validity Check (beta) checks the other direction: it reads your test reports, matches each instrument to its certificate by identity, and checks validity on the date of use, range and traceability, citing every finding.

Frequently asked questions

Is a calibration sticker on the gauge enough?

Usually not for a customer test. The sticker shows status on the shop floor, but inspectors want the certificate itself, matched to the instrument ID on the test report.

Does the laboratory have to be accredited?

Only if the order or your quality system says so. Many customer specifications ask for an accredited laboratory, often to ISO/IEC 17025. Check the purchase order's quality clauses.

References

Metrological traceability

NIST

Visit source

ISO/IEC 17025:2017 General requirements for the competence of testing and calibration laboratories

ISO

Visit source

Related Pages