Download the hygienic design checklist
XLSX
Hygienic design requirement checklist (Excel)
Header block, 8 columns, a status drop-down, Deviation rows in red and Clarification rows in amber, frozen header row, filters and a How to use sheet.
CSV
Hygienic design requirement checklist (CSV)
The example rows as plain CSV (UTF-8), for Google Sheets or any other tool.
Both files are free under CC BY 4.0, with no form to fill in. The XLSX opens in Excel, Google Sheets, LibreOffice and Numbers. The CSV carries the table only; the header block is in the XLSX.
When a customer sends a hygienic design specification
Food, dairy and beverage producers usually attach their own hygienic design specification to an enquiry. It draws on published guidance, often the EHEDG guidelines or 3-A Sanitary Standards, and for some equipment ASME BPE, but the figures that bind you are the ones the customer wrote down. This checklist is a short, structured answer to that document. It makes you look at each subject in turn across the whole scope of supply, and it shows the customer where you differ before the order is placed, not at the acceptance test.
- Proposal and application engineers, who fill it in with the offer.
- Design engineers, who check the offered column against the drawings.
- The customer's hygiene or quality engineer, who will read the deviations and clarifications first.
For a full clause-by-clause answer, use the compliance matrix template; this checklist is the hygienic part of that work, grouped by subject. For background, see hygienic design and food processing equipment manufacturers.
Header block
| Field | Example |
|---|---|
| Project | Example Dairy Filling Line (fictional) |
| Customer | Example Dairy Ltd (fictional) |
| Enquiry no. | RFQ-EX-6410 |
| Customer's hygienic design specification | HDS-EX-02 Rev 1 (invented) |
| Guidelines and standards the customer names | As listed in HDS-EX-02 section 2, with their editions |
| Equipment offered | Mixing tank skid with agitator, pump and pipework (fictional) |
| Offer no. | OF-EX-6410 Rev A |
| Checklist no. | HDC-EX-6410 |
| Date | 2027-03-22 |
| Prepared by | Proposal engineer |
| Checked by | Design engineer |
Example rows: a mixing tank skid for a dairy
| Item | Requirement area | Customer clause | What the customer specifies | What is offered | Status | Evidence document | Remark |
|---|---|---|---|---|---|---|---|
| 1 | Guidelines and editions | HDS-EX-02 2.1 | Design to the guidelines and standards listed in section 2 | Offer is based on the documents listed; two are listed without an edition | Clarification | Offer OF-EX-6410 section 3 | Ask the customer which editions apply, and state the editions the offer assumes. |
| 2 | Product-contact materials | HDS-EX-02 3.1 | Product-contact metal parts in the stainless steel grade named in clause 3.1 | Grade as specified for tank, agitator, pipework and pump wetted parts | Complies | Materials list ML-EX-6410 Rev A | |
| 3 | Material certificates | HDS-EX-02 3.2 | Material certificates of the type named in clause 3.2 for all product-contact parts | As specified for tank and pipework. The pump maker's standard certificate is a different type | Clarification | Pump quotation PQ-EX-118 | Ask whether the pump maker's certificate type is accepted. The specified type is a priced option. |
| 4 | Surface finish | HDS-EX-02 4.1 | Product-contact surface roughness as specified by the customer in clause 4.1, with measurement records | Finish as specified on tank internals and pipework, measured and recorded at the points the customer's clause names | Complies | Surface finish procedure SF-EX-01 Rev B | |
| 5 | Weld finish | HDS-EX-02 4.3 | Product-contact welds finished as specified by the customer in clause 4.3 | Tank internal welds ground as specified. Orbital pipe welds left as welded and inspected | Clarification | Weld procedure WP-EX-07; weld inspection plan | Clause 4.3 does not say whether as-welded orbital welds are accepted. Ask. |
| 6 | Drainability | HDS-EX-02 5.1 | Equipment to drain by gravity, with slopes as specified by the customer | Tank bottom and pipework sloped as specified. The pump casing empties through a casing drain valve, not by gravity | Deviation | P&ID PID-EX-6410-01 Rev A; general arrangement GA-EX-6410 | Deviation list item 2. A casing drain valve is included. |
| 7 | Dead legs | HDS-EX-02 5.3 | Dead legs limited as specified by the customer in clause 5.3 | Instrument tees and branch valves chosen to the customer's limit. The sample point on the outlet line is longer | Deviation | PID-EX-6410-01 Rev A, line 4 | Deviation list item 3. A flush-mounted sample valve is offered as an option. |
| 8 | Seals and elastomers | HDS-EX-02 6.1 | Product-contact elastomers of the materials named, each with a food contact declaration for the regulations the customer lists | Gasket, valve seat and pump seal elastomers as named, with declarations for the regulations listed | Complies | Declarations DoC-EX-11 to DoC-EX-14 | |
| 9 | Fasteners and threads in the product zone | HDS-EX-02 6.4 | No exposed threads or fasteners in the product zone unless the clause allows it | None in the product zone. Agitator blades are welded to the hub | Complies | Agitator drawing AG-EX-6410 Rev A | |
| 10 | Cleanability and CIP provisions | HDS-EX-02 7.1 | Cleanable in place with the customer's CIP programme; spray device coverage proven by the test the customer names | Spray device fitted; coverage test offered at the factory acceptance test | Clarification | Tank datasheet DS-EX-T-01; FAT plan | The enquiry gives no CIP supply flow or pressure at the skid inlet. Ask for both before the spray device is sized. |
| 11 | Lubricants | HDS-EX-02 8.1 | Lubricants with possible incidental product contact to carry the registration the customer specifies | Agitator gearbox lubricant as specified; all lubricants listed in the manual | Complies | Lubricant list LL-EX-6410 | |
| 12 | Documentation | HDS-EX-02 9.1 | Hygienic design documentation pack as listed in clause 9.1, including a hygienic design certificate for the pump under the scheme the customer names | Material certificates, surface finish records, weld log, elastomer declarations and lubricant list. The pump model offered is not certified under the scheme named | Deviation | Pump quotation PQ-EX-118 | Deviation list item 4. A certified pump model is a priced alternative. |
The requirement cells say "as specified by the customer" wherever the customer's document would give a figure. No roughness value, slope, dead-leg limit or certificate type in the example is presented as a requirement of EHEDG, 3-A or any other guideline or standard; those documents and your contract hold the figures. Check the governing standard or contract. Every example value is invented: the project, customer, bidders, purchase order, prices and every document, certificate, serial and report number do not exist. Standards are named but not quoted.
Status values
| Status | Use it when |
|---|---|
| Complies | What you offer meets the customer's clause as written, and a document shows it. |
| Clarification | The clause is unclear, leaves something out, or your offer meets it by a different route. Ask the question in writing. |
| Deviation | What you offer does not meet the clause as written. Say what you offer instead and carry the row to your deviation list. |
| Not applicable | The clause does not apply to the equipment offered, for example a clause on product-zone bearings where there are none. Say why. |
Columns and what to write
| Column | What to write |
|---|---|
| Item | Running number. |
| Requirement area | The subject of the row, such as product-contact materials, surface finish, drainability or seals. |
| Customer clause | The clause of the customer's hygienic design specification. If the customer has no clause on the subject, write None and treat the row as a question to ask. |
| What the customer specifies | The requirement in the customer's own words, including any figure it gives. Do not fill in a figure from memory or from a guideline the customer did not name. |
| What is offered | What your equipment has, in the same terms, for every part of the scope including bought-in items. |
| Status | Complies, Clarification, Deviation or Not applicable (drop-down). Deviation rows turn red; Clarification rows amber. |
| Evidence document | The drawing, materials list, certificate, declaration or procedure that supports the row, with its number and revision. |
| Remark | The question to ask, the alternative you offer, or the deviation list item. |
How to fill in the checklist
- Fill in the header block: the customer's hygienic design specification with its revision, and the guidelines and standards it names with their editions.
- Read the customer's specification from start to finish and write the clause number against each requirement area. Add rows for anything it covers that the template does not.
- In What the customer specifies, copy the customer's wording, including any figure. Leave figures out if the customer gives none; do not borrow one from a guideline the customer did not name.
- In What is offered, describe your equipment in the same terms. Check bought-in items one by one: pumps, valves, instruments and seals are where the gaps usually are.
- Set the status. Deviation rows turn red and Clarification rows amber.
- Name the evidence document for every Complies row. A row with no evidence is not ready to send.
- Carry each Deviation to your deviation list and each Clarification to your clarification list, and put the item number in the Remark column.
- Have the design engineer check the list before the offer goes out, and keep it with the offer file.
Reading the customer's specification against your own documents
Hygienic design clauses are scattered. Some sit in the hygienic design specification, others in the user requirements, the datasheets or a cleaning standard attached at the back. In OdysseyGPT's Tender & Quotation module, Document Review and Customer Specification Review (beta) read the customer's package and your datasheets, list each requirement and show what your documents say against it, quoting both pages. Deviation Register (beta) keeps the deviations and the customer's answers in one place. An engineer sets every status. Tools marked beta are open on request, and we onboard each team ourselves.
See how OdysseyGPT reviews a tender
Tell us how your team reviews tenders today. We can walk through an example together.