OdysseyGPT

Glossary term

Clean in Place (CIP)

Cleaning the inside of process equipment and pipework by circulating or spraying cleaning liquids through it, without taking it apart.

Last reviewed by the OdysseyGPT team

What it is

Clean in place, or CIP, is cleaning the inside of process equipment and pipework by circulating or spraying rinse water and cleaning solutions through it, without dismantling. It is the usual method in liquid food and beverage plants. It requires equipment that every cleaning liquid can reach, that drains, and whose seals stand the chemicals and temperatures used.

Key Takeaways

  • CIP cleans without dismantling. COP means parts are removed and washed.
  • Chemistry, temperature, mechanical action and time together give the result.
  • CIP asks for full liquid contact, drainage, suitable seals and adequate flow.
  • The specification should state the cleaning station's limits and any coverage test wanted.

Why it matters

Clean in place, written CIP, is the method most liquid food and beverage plants use to clean tanks, pipework, heat exchangers and fillers between production runs. Rinse water and cleaning solutions are pumped from a cleaning station through the equipment and back, following the path the product took. Pipes are cleaned by the flow of liquid along the wall. Tanks are cleaned by spray devices that wet the inside surface. A typical programme runs a first rinse, a detergent step, a further rinse, sometimes an acid step or a disinfection step, and a final rinse, though each site sets its own. The result depends on four things working together: the chemistry, the temperature, the mechanical action of the liquid and the time. The opposite is cleaning out of place, COP, where parts are removed and washed in a tank or by hand. CIP places demands on the equipment. Every product-contact surface has to be reached by the liquid, so dead ends, pockets and shadowed areas matter. The equipment has to drain. Seals and gaskets have to stand the chemicals and temperatures used. Pumps and valves have to pass the flow the circuit needs. For this reason hygienic design references treat equipment cleaned in place as its own case: EHEDG certifies such equipment under its own class, 3-A authorisations state whether a model is for cleaning in place or out of place, and EHEDG publishes guidelines on cleaning-in-place installations and on tank cleaning. A customer specification normally states which items are cleaned in place, the limits of the site's cleaning station, and any test it wants at the factory acceptance test, such as a spray coverage check. Steaming or sterilising in place is a separate step with its own requirements.

How OdysseyGPT uses it

Document Review compares the cleaning requirements in the customer's specification with your datasheets, cleaning instructions and FAT procedure, and quotes both sides for each finding, including requirements your documents do not mention. FAT Readiness Check (beta) checks that the documents a witnessed test depends on are in place. OdysseyGPT reads documents only. It does not design a cleaning circuit, calculate flow or coverage, or test whether equipment comes clean.

Evaluation questions

What does a customer specification usually say about CIP?

It states which items are cleaned in place, the detergents, temperatures and flow the site's cleaning station provides, who supplies spray devices and return pumps, and any coverage or cleanability test to be shown at the factory acceptance test.

Frequently asked questions

What is the difference between CIP and COP?

CIP, clean in place, cleans equipment without dismantling by circulating or spraying liquids through it. COP, clean out of place, means parts are taken off and washed in a tank or by hand. One machine can use both for different parts.

What is the difference between CIP and SIP?

CIP removes soil with rinses and cleaning solutions. SIP, steaming or sterilising in place, follows cleaning and uses steam to reduce micro-organisms on the cleaned surfaces. Equipment for SIP must also stand the temperature and pressure involved.

What is a spray coverage or riboflavin test?

It is a check that spray devices wet the whole inside of a tank. A fluorescent tracer is applied to the surfaces, the spray devices are run with water, and the surfaces are inspected under ultraviolet light for tracer left behind. The contract sets the method and acceptance rule.

Does a CIP requirement change the equipment design?

Often. Cleaning in place calls for full liquid contact, drainage, suitable seals, spray devices in tanks and components that pass the cleaning flow. If your standard design assumes strip-down cleaning, a CIP clause is a design change to price.

References

EHEDG Guideline Catalogue

EHEDG

Guideline numbers and titles. Most guidelines are for members or for sale.

Visit source

Certification Types & Classes

EHEDG

The class for equipment wet cleaned in place without dismantling.

Visit source

Third-Party Verification (TPV)

3-A Sanitary Standards, Inc.

States that authorised models are listed as CIP, COP or both.

Visit source

Related Pages