What is API 617?
API Standard 617 is titled Axial and Centrifugal Compressors and Expander-compressors. It gives minimum requirements for these machines in petroleum, chemical and gas industry services that handle air or gas. It is a purchase specification as much as a design standard: it is written so that an owner and a compressor maker can agree one machine by filling in datasheets and choosing options.
Published summaries list three kinds of machine it does not cover: fans, axial-inflow hot gas expanders, and packaged integrally geared centrifugal compressors for plant and instrument air. API has other standards for fans and for packaged air compressors. If an enquiry names API 617 for a machine of one of these kinds, ask which standard the customer means before you quote.
Resellers listed the ninth edition, dated April 2022, as the active edition when we checked in November 2026. Long projects often name an older edition. Use the edition your contract names, and say so on the first page of your compliance statement.
How the standard is arranged
API 617 is split into parts. The first part holds the rules shared by all machines. Each later part is read together with the first and adds the rules for one machine type.
| Part | Covers | What a bid engineer takes from it |
|---|---|---|
| Part 1 | General requirements for all machines in the standard | Shared rules for casings, rotating parts, materials, inspection, testing, preparation for shipment and vendor data |
| Part 2 | Centrifugal and axial compressors that are not integrally geared | Rules for single-shaft process compressors, read with Part 1 |
| Part 3 | Integrally geared centrifugal compressors | Rules for machines with pinion shafts driven from one bull gear, read with Part 1 |
| Part 4 | Expander-compressors | Rules for an expander and compressor on one shaft, read with Part 1 |
The standard also carries annexes. Published summaries point to sample datasheets and to guidance on allowable nozzle loads among them. A compliance statement should say which parts apply to the machine offered, because a clause number means little without its part.
What the purchaser's datasheet fixes
API machinery standards leave many decisions to the purchaser. The clauses that need a decision are marked in the text, and the answers are recorded on the datasheet or in the requisition. For a compressor, the datasheet is where the customer states the duty and ticks the options. A bid engineer should treat every ticked option as a requirement and every blank as a question.
| Area | What the customer states | Why it matters to the offer |
|---|---|---|
| Operating cases | Gas composition, inlet and discharge conditions and flow for each case, and which case is guaranteed | The guarantee point sets the aerodynamic design and the performance test basis |
| Gas properties and contaminants | Molecular weight range, corrosive or sour components, liquids or solids in the gas | Drives materials, seals and washing or coating provisions |
| Site and utilities | Ambient range, area classification, cooling water, power and instrument air | Sets driver sizing, cooler duty and electrical certification |
| Driver and train | Motor, steam turbine or gas turbine, gear unit, coupling type and who supplies each | Splits scope between you, the driver maker and the packager |
| Shaft seals | Seal type and the sealing system that supports it | Seal gas panel scope is a frequent source of clarifications |
| Materials | Casing, impeller and shaft materials, and any sour-service requirement | A material upgrade changes price and lead time |
| Analyses and studies | Rotor dynamic and other studies the customer wants reported | Each study is engineering time and a deliverable |
| Inspection and testing | Which tests are required, which are witnessed or observed, and any optional tests | Sets test bay time, test gas, notice periods and cost |
Shop tests in outline
Compressor shop tests fall into two groups. The first group is run on every machine built to the standard. The second group is run only when the purchaser asks for it on the datasheet. The table gives the usual split as trade publications describe it. Confirm it against the edition and part that your contract names, because the list has changed between editions.
| Test | What it shows | Usual status |
|---|---|---|
| Hydrostatic test of pressure casings | The casing holds pressure without leaking | Run on every machine |
| Impeller overspeed test | Each impeller withstands a speed above its maximum continuous speed | Run on every impeller |
| Mechanical running test | The assembled machine runs at speed with acceptable vibration and bearing temperatures | Run on every machine |
| Assembled compressor gas leakage test | The assembled casing and its joints are gas-tight | Run on every machine |
| Performance test | Head, flow and power at the guarantee point, usually to ASME PTC 10 | When specified |
| Complete unit or string test | Compressor, driver, gear and auxiliaries run together | When specified |
| Full-load, full-pressure or full-speed test | Behaviour at or near site conditions, including rotor stability | When specified |
| Sound level test and post-test inspection | Noise against the limit, and the condition of internals after running | When specified |
ASME PTC 10 describes two kinds of performance test. A Type 1 test uses the specified gas at conditions close to the guarantee point. A Type 2 test uses a substitute gas when the real gas is impractical or unsafe on a test stand, and converts the results. Which type the customer expects changes the test loop, the test gas and the price, so state it in the offer.
Witnessed, observed or by certificate
Each test on the datasheet also carries an attendance level. A witnessed test is a hold point: the test waits for the customer. An observed test goes ahead on the notified date whether or not the customer attends. Record the level for each test in your compliance statement, with the notice period you can meet.
What to check in a tender against API 617
| Check | Why it matters |
|---|---|
| Edition of API 617 named, and which parts apply to the machine | Clause numbers and test lists differ between editions and parts |
| Guarantee case identified among the operating cases | A second guaranteed case can change the staging or the driver |
| Gas composition and its range, including sour or corrosive components | Sets materials and may add sour-service evidence |
| Every ticked option on the datasheet, and every blank | A ticked option is a requirement; a blank needs a clarification |
| Optional tests specified: performance, string, full-load, sound | Each one adds test bay time and may need a test gas loop |
| Performance test type and test gas | A Type 1 test with the real gas may not be possible on your stand |
| Attendance level for each test, with notice periods | Hold points set the delivery date |
| Scope split for driver, gear, seal system, lube console and controls | Unclear splits become claims after the order |
| Studies and reports the customer wants, with submission dates | They are deliverables on the vendor document list |
| Owner specification clauses that add to or change the standard | These are where most deviations come from |
OdysseyGPT's Document Review compares the customer's compressor specification and requisition with your own base documents, in both directions, and drafts a compliance matrix and deviation list. Each row quotes the clause it came from. Datasheet Comparison (beta) sets the customer's datasheet beside yours field by field. OdysseyGPT reads documents. It does not run rotor dynamic studies or tests, and your engineers decide every status.
Talk through your tender review