What it is
A pump performance test is a shop test that runs the pump at several flows and records flow, head, power and efficiency at each. The tested curve is compared with the guarantee point in the order, using the tolerance of an agreed standard such as ISO 9906, ANSI/HI 14.6 or API 610.
Key Takeaways
- The test measures flow, head, power and efficiency across the curve.
- Acceptance is judged at the guarantee point with an agreed tolerance grade.
- ISO 9906 and ANSI/HI 14.6 are harmonised; API 610 has its own clauses.
- An NPSH test is separate and usually run only when specified.
Why it matters
A pump performance test, also called a hydraulic performance test, is run on a test loop at the manufacturer's works, normally with clean cold water. The pump is run at a series of flows from shut-off or minimum flow up to beyond the rated flow. At each point the test engineer records flow, suction and discharge pressure, speed and power, and calculates head and efficiency. The points make up the tested curve. The result is then compared with the guarantee point, the flow and head stated in the order, using an agreed tolerance. ISO 9906 is the international standard for hydraulic performance acceptance tests of rotodynamic pumps. It defines acceptance grades numbered 1, 2 and 3, from the tightest to the widest tolerance, with variants that say whether the tolerance band is two-sided or one-sided. The Hydraulic Institute's ANSI/HI 14.6 is harmonised with it. API 610 has its own performance test clauses and tolerances for the pumps it covers, and its performance test is generally described as applying to every pump unless the purchaser says otherwise. A test of net positive suction head required is a separate test, usually run only when specified. Results measured on water are corrected to the contract liquid and speed where these differ, by methods the standard or the order names.
How OdysseyGPT uses it
OdysseyGPT does not test pumps and does not calculate or correct pump curves. Document Review reads the customer's specification and datasheet for the test standard, the acceptance grade, the witness level and any added tests, and compares them with your standard test procedure. Calibration Validity Check (beta) matches each instrument named on the test record to its calibration certificate and checks it was valid on the test date. Each finding quotes its source for an engineer to review.
Evaluation questions
What should a bid engineer check about the performance test in a tender?
The test standard and acceptance grade, the number of test points, whether an NPSH test or a string test with the contract driver is required, the witness level, and any tolerance tighter than the standard.
What is the difference between a witnessed test and a certified test?
At a witnessed test the customer or its inspector attends and the test waits for them. A certified, or non-witnessed, test is run by the manufacturer alone, and the customer receives the signed test record.
What should a pump performance test record show?
The pump's serial number, the test date and procedure, the readings and calculated values at each point, the tested curve against the guarantee, the instruments used and their calibration status, and the signatures.
Frequently asked questions
What is a pump performance test?
A shop test that measures flow, head, power and efficiency at several operating points, draws the tested curve and compares the guarantee point with the values in the order.
Which standards cover pump performance testing?
ISO 9906 for rotodynamic pumps generally, ANSI/HI 14.6 in North America, which is harmonised with ISO 9906, and the test clauses of API 610 for the centrifugal pumps that standard covers.
What are the ISO 9906 acceptance grades?
Three grades, numbered 1 to 3. Grade 1 has the tightest tolerances and grade 3 the widest. Letter suffixes say whether the tolerance is two-sided or one-sided. The order should name the grade.
Is an NPSH test part of the performance test?
No. It is a separate test that finds the suction head at which the pump's head starts to fall. It is usually run only when the purchaser specifies it, and it is often priced separately.
References
ISO 9906: Rotodynamic pumps — Hydraulic performance acceptance tests — Grades 1, 2 and 3
ISO
Paid standard.
Specification of pump performance test acceptance
Pumps & Systems
Understanding the effects of selecting a pump performance test acceptance grade
Hydraulic Institute / Europump
Performance testing centrifugal pumps
Pumps & Systems