What is API 674?
API Standard 674 is titled Positive Displacement Pumps—Reciprocating. Its public abstract says it covers the minimum requirements for reciprocating positive displacement pumps and pump units for use in petroleum, petrochemical and natural gas industry services. A pump unit means the pump with its driver and the items between them, so the standard reaches beyond the bare pump.
The same abstract says what is left out: controlled-volume pumps, hydraulically driven pumps and rotary pumps. It points the reader to API 675 for controlled-volume pumps and to API 676 for rotary pumps.
The third edition was first published in 2010 and has been updated by errata since. Catalogue pages showed a further issue dated January 2026 when we checked. Quote to the edition and errata your contract names, and ask if the enquiry gives only the number.
Direct-acting and power pumps
The standard takes in two families of reciprocating pump. Knowing which one the enquiry describes tells you which clauses and which datasheet fields apply.
| Family | How it is driven | Where the tender detail sits |
|---|---|---|
| Power pump (power-frame type) | A crankshaft in a power end turns rotary motion from a motor, engine or turbine into the stroke of plungers or pistons in a liquid end | Number of plungers, speed, gear or belt reduction, power end lubrication, packing and liquid end materials |
| Direct-acting pump | A steam or gas cylinder drives the liquid piston directly through a common rod, with no crankshaft | Drive fluid conditions, valve gear, and the liquid end materials |
Reciprocating pumps deliver a nearly fixed volume per stroke, so flow changes with speed and hardly at all with discharge pressure. That is why the enquiry normally asks for a relief valve on the discharge, and why the scope split for that valve is worth a line in your offer.
API 674 compared with API 610, API 675 and API 676
| Standard | Pump type | Typical use |
|---|---|---|
| API 610 | Centrifugal pumps | Most process pumping duties, where flow varies with head |
| API 674 | Reciprocating positive displacement pumps and pump units, direct-acting and power-frame | High pressure at modest flow, such as injection and charge duties |
| API 675 | Controlled-volume positive displacement pumps, also called metering pumps | Dosing, where the delivered volume must be set and repeated accurately |
| API 676 | Rotary positive displacement pumps, such as gear and screw pumps | Viscous liquids and lubrication duties |
An enquiry sometimes names the wrong one of these, most often API 674 for a metering pump or API 610 clauses copied into a reciprocating pump specification. Do not answer a clause that cannot apply to your machine with a plain "comply". Raise it as a clarification and carry the answer onto the technical deviation list.
Pulsation and suction conditions
A reciprocating pump starts and stops the liquid in its suction and discharge lines on every stroke. The result is pressure pulsation, which can shake piping and starve the pump of liquid. Two ideas follow from this, and both show up in tenders.
- Acceleration head. Some of the suction head is used to speed up the liquid in the suction line on each stroke. It is subtracted, with friction and vapour pressure, when working out the net positive suction head available. A long or narrow suction line can make a pump that looks fine on paper cavitate.
- Pulsation control. Dampeners, pulsation vessels, orifice plates and piping changes are the usual ways to control pulsation. Who supplies them, and who sizes them, is a scope question.
API 674 names graded design approaches for pulsation and mechanical analysis, and specialist firms describe their studies by those approach numbers. The deeper the approach, the more it depends on the customer's piping layout, which the pump maker does not control. The tender should say which approach applies, who carries out the study and when the piping data will arrive. If it does not, ask.
What to check in a tender against API 674
| Check | Why it matters |
|---|---|
| The pump is in scope: reciprocating, not metering or rotary | API 675 and API 676 have their own datasheets and tests |
| Edition and errata of API 674 named in the requisition and specification | Documents in one package can name different issues |
| Liquid, temperature, viscosity, solids and vapour pressure on the datasheet | They set liquid end materials, valves and packing |
| Suction conditions and the suction piping the customer assumes | Acceleration head can remove the suction margin |
| Pulsation study: approach, who performs it and who supplies piping data | A study without piping data cannot be finished on time |
| Dampeners and relief valve: in your scope or the customer's | Missing items are found at commissioning if nobody owns them |
| Driver, gear or belt drive, baseplate and guards | The standard covers pump units, so the split must be clear |
| Shop tests required and their attendance level | Witnessed tests need notice and test bay time |
| Material certificates, NDE and sour-service requirements for the liquid end | They add cost and lead time to forgings |
| Vendor drawing and data requirements, with dates | Late documents hold up payment as surely as late hardware |
Document Review reads the customer's pump specification and requisition against your standard offer documents and lists each requirement as met, not met or unclear, with a quote from both sides. After the order, the Deviation Register (beta) tracks each agreed deviation to the customer's decision. OdysseyGPT does not run pulsation studies or read piping isometrics. It checks the written documents, and your engineers make the call.
Talk through your tender review
See how OdysseyGPT reviews a tender
Tell us how your team reviews tenders today. We can walk through an example together.