The short answer

API Standard 674 covers reciprocating positive displacement pumps and pump units for petroleum, petrochemical and natural gas services. It includes direct-acting and power-frame pumps. It does not cover controlled-volume (metering) pumps, which fall under API 675, or rotary pumps, which fall under API 676. Centrifugal pumps fall under API 610.

Key Takeaways

  • API 674 is the API standard for reciprocating pumps: plunger and piston pumps, direct-acting or crank-driven.
  • Metering pumps (API 675) and rotary pumps (API 676) are outside it.
  • Pulsation and suction conditions matter more than on a centrifugal pump, and the piping is part of the problem.
  • Check which pulsation study the customer wants and who supplies the dampeners.

See how OdysseyGPT reviews a tender. Tell us how your team reviews tenders today. We can walk through an example together. Book a call

What is API 674?

API Standard 674 is titled Positive Displacement Pumps—Reciprocating. Its public abstract says it covers the minimum requirements for reciprocating positive displacement pumps and pump units for use in petroleum, petrochemical and natural gas industry services. A pump unit means the pump with its driver and the items between them, so the standard reaches beyond the bare pump.

The same abstract says what is left out: controlled-volume pumps, hydraulically driven pumps and rotary pumps. It points the reader to API 675 for controlled-volume pumps and to API 676 for rotary pumps.

The third edition was first published in 2010 and has been updated by errata since. Catalogue pages showed a further issue dated January 2026 when we checked. Quote to the edition and errata your contract names, and ask if the enquiry gives only the number.

Direct-acting and power pumps

The standard takes in two families of reciprocating pump. Knowing which one the enquiry describes tells you which clauses and which datasheet fields apply.

The two families of reciprocating pump in API 674 (general industry usage)
FamilyHow it is drivenWhere the tender detail sits
Power pump (power-frame type)A crankshaft in a power end turns rotary motion from a motor, engine or turbine into the stroke of plungers or pistons in a liquid endNumber of plungers, speed, gear or belt reduction, power end lubrication, packing and liquid end materials
Direct-acting pumpA steam or gas cylinder drives the liquid piston directly through a common rod, with no crankshaftDrive fluid conditions, valve gear, and the liquid end materials

Reciprocating pumps deliver a nearly fixed volume per stroke, so flow changes with speed and hardly at all with discharge pressure. That is why the enquiry normally asks for a relief valve on the discharge, and why the scope split for that valve is worth a line in your offer.

API 674 compared with API 610, API 675 and API 676

Four API pump standards by scope (own summary of public scope statements)
StandardPump typeTypical use
API 610Centrifugal pumpsMost process pumping duties, where flow varies with head
API 674Reciprocating positive displacement pumps and pump units, direct-acting and power-frameHigh pressure at modest flow, such as injection and charge duties
API 675Controlled-volume positive displacement pumps, also called metering pumpsDosing, where the delivered volume must be set and repeated accurately
API 676Rotary positive displacement pumps, such as gear and screw pumpsViscous liquids and lubrication duties

An enquiry sometimes names the wrong one of these, most often API 674 for a metering pump or API 610 clauses copied into a reciprocating pump specification. Do not answer a clause that cannot apply to your machine with a plain "comply". Raise it as a clarification and carry the answer onto the technical deviation list.

Pulsation and suction conditions

A reciprocating pump starts and stops the liquid in its suction and discharge lines on every stroke. The result is pressure pulsation, which can shake piping and starve the pump of liquid. Two ideas follow from this, and both show up in tenders.

  • Acceleration head. Some of the suction head is used to speed up the liquid in the suction line on each stroke. It is subtracted, with friction and vapour pressure, when working out the net positive suction head available. A long or narrow suction line can make a pump that looks fine on paper cavitate.
  • Pulsation control. Dampeners, pulsation vessels, orifice plates and piping changes are the usual ways to control pulsation. Who supplies them, and who sizes them, is a scope question.

API 674 names graded design approaches for pulsation and mechanical analysis, and specialist firms describe their studies by those approach numbers. The deeper the approach, the more it depends on the customer's piping layout, which the pump maker does not control. The tender should say which approach applies, who carries out the study and when the piping data will arrive. If it does not, ask.

What to check in a tender against API 674

Reciprocating pump enquiry checks
CheckWhy it matters
The pump is in scope: reciprocating, not metering or rotaryAPI 675 and API 676 have their own datasheets and tests
Edition and errata of API 674 named in the requisition and specificationDocuments in one package can name different issues
Liquid, temperature, viscosity, solids and vapour pressure on the datasheetThey set liquid end materials, valves and packing
Suction conditions and the suction piping the customer assumesAcceleration head can remove the suction margin
Pulsation study: approach, who performs it and who supplies piping dataA study without piping data cannot be finished on time
Dampeners and relief valve: in your scope or the customer'sMissing items are found at commissioning if nobody owns them
Driver, gear or belt drive, baseplate and guardsThe standard covers pump units, so the split must be clear
Shop tests required and their attendance levelWitnessed tests need notice and test bay time
Material certificates, NDE and sour-service requirements for the liquid endThey add cost and lead time to forgings
Vendor drawing and data requirements, with datesLate documents hold up payment as surely as late hardware

Document Review reads the customer's pump specification and requisition against your standard offer documents and lists each requirement as met, not met or unclear, with a quote from both sides. After the order, the Deviation Register (beta) tracks each agreed deviation to the customer's decision. OdysseyGPT does not run pulsation studies or read piping isometrics. It checks the written documents, and your engineers make the call.

Talk through your tender review

See how OdysseyGPT reviews a tender

Tell us how your team reviews tenders today. We can walk through an example together.

Book a call

Frequently asked questions

What is API 674?

The American Petroleum Institute standard for reciprocating positive displacement pumps and pump units in petroleum, petrochemical and natural gas services. It covers direct-acting and power-frame pumps.

What is the difference between API 674 and API 675?

API 674 covers reciprocating process pumps. API 675 covers controlled-volume pumps, also called metering or dosing pumps, where the delivered volume must be set and repeated accurately. API 674 says controlled-volume pumps are outside its scope.

What is the difference between API 674 and API 610?

API 610 covers centrifugal pumps. API 674 covers reciprocating positive displacement pumps. The working principle differs, so the datasheets, the suction calculations and the pulsation requirements differ too.

Does API 674 cover rotary pumps?

No. Rotary positive displacement pumps, such as gear and screw pumps, fall under API 676. Hydraulically driven pumps are also outside API 674.

Why do reciprocating pump tenders ask for a pulsation study?

Each stroke starts and stops the liquid in the piping, which causes pressure pulsation. A study predicts it and sizes the dampeners or piping changes needed. The study depends on the customer's piping layout, so agree who supplies that data.

References

API Standard 674: Positive Displacement Pumps—Reciprocating

American Petroleum Institute

Paid standard. Buy the edition your contract names from API or a reseller.

API standards catalogue

American Petroleum Institute

Visit source

API Std 674 catalogue entry and scope abstract

Standard Online

Public abstract: types included and excluded.

Visit source

API Std 676 catalogue entry and scope abstract

Standard Online

Visit source

API Standard 675 positive displacement pumps

Pumps & Systems

Visit source

Reciprocating pump pulsation and mechanical analysis

Wood

Design approaches and pulsation control methods.

Visit source

Related Pages