OdysseyGPT

Guide

Pump datasheet: every field explained, with a worked check

For engineers completing a centrifugal pump data sheet, or comparing a supplier's sheet with the customer's before the offer goes out.

By Ademola Afolabi, Founder, New Odyssey Ltd · Last reviewed:

The short answer

A pump datasheet records the liquid, the operating conditions, the performance, the construction, the materials, the seal, the driver and the tests for one pump. The buyer fills in the duty and the maker fills in the selected pump. Compare the two field by field, in the same units, before you accept either.

Key Takeaways

  • Start with the liquid and the operating conditions: every other field depends on them.
  • Check the margin between NPSH available and NPSH required against the customer's rule.
  • Materials, seal arrangement and testing are where a supplier's sheet most often differs.
  • A blank field is a finding too. Ask for it before the order.

What a pump datasheet is

A pump datasheet, also written pump data sheet, is the agreed technical record for one pump or one group of identical pumps. The buyer states the service: what liquid, how much, from what pressure to what pressure. The maker answers with a selected pump and its curve. Once both sides sign it, the sheet sits in the order beside the specification.

Most sheets for process pumps follow the layout in a pump standard, so the fields appear in a familiar order. Catalogue sheets for small pumps are shorter, but they answer the same questions.

Compare the customer's pump sheet with yours

Bring the customer's pump data sheet and the sheet your supplier or your own team returned. We show you each field that differs, each blank and the cell both values came from.

Request a demo

Centrifugal pump data sheet, field by field

Centrifugal pump data sheet fields (own summary)
FieldWhat it tells youCheck against the specification
Item number, service and quantityWhich pumps, and how many run and stand byTag, service and number of pumps match the requisition
LiquidName, pumping temperature, specific gravity, viscosity, vapour pressure, solids and corrosive contentSame values as the process data, at the same temperature
CapacityRated flow, with normal and minimum flowRated flow matches, in the same unit
Suction and discharge pressurePressures at the pump nozzles, rated and maximumGauge or absolute is stated and matches
Differential headThe head the pump must add at rated flowHead matches, and any tolerance rule is met
NPSH available and requiredSuction head the system gives and the pump needsThe margin between them meets the customer's rule
Pump type and sizeConstruction type, stages, nozzle sizesThe type is one the specification permits for the service
PerformanceEfficiency, rated power, best efficiency point, minimum continuous flow, speedRated flow sits in the preferred region of the curve
ImpellerRated, maximum and minimum diameterRoom to increase head if the specification asks for it
Casing designMaximum allowable working pressure and temperature, hydrostatic test pressureAt least the specified design conditions
NozzlesSize, flange rating, facing and positionRating and facing match the piping class
MaterialsCasing, impeller, shaft, wear rings, and the material classClass and grades as specified, with any sour service requirement
Mechanical sealSeal type, arrangement, materials and flush planArrangement and plan as specified
Bearings and lubricationBearing type and how they are lubricatedMatches the specified system
DriverMotor or turbine rating, speed, enclosure and area classificationRating covers the power the specification requires
Inspection and testingPerformance, NPSH and hydrostatic tests, witnessed or observedEach required test is listed with the right witness level
Weights and drawingsPump, baseplate and driver weights, drawing numbersFilled in before the order

Which pump data sheet form applies

The form usually follows the standard the pump is bought to. The fields overlap, but the level of detail differs.

  • API 610: centrifugal pumps for refinery, petrochemical and gas service. Its sheet is the most detailed, with materials classes and test requirements. See the API 610 pump datasheet review.
  • ASME B73.1: horizontal end suction pumps for chemical process service, with standard dimensions.
  • ISO 5199: technical requirements for centrifugal pumps in general process service.
  • API 682: the shaft sealing system, which often has a seal data sheet of its own.
  • Company forms: many buyers issue their own sheet based on one of the above. Use theirs, not yours.

Worked example: customer sheet against supplier sheet

The values below are made up. They show the kinds of result a line by line comparison gives, and why the same number in two units is not a difference while a blank is.

An illustrative comparison of two pump data sheets
FieldCustomer sheetSupplier sheetResult
Pumping temperature149 °C300 °FSame value after conversion
Differential head85 m85.0 mSame value, formatting only
NPSH available / required4.5 m available4.2 m requiredMargin of 0.3 m: compare with the customer's margin rule
Materials classS-6S-5Different class: raise it
Seal flush planPlan 53BPlan 11Different plan: raise it
Driver ratingStatedBlankMissing field: ask the supplier
Performance testWitnessedNot witnessedDifferent witness level: raise it

Four of the seven lines need a decision. Each belongs in the technical deviation list or goes back to the supplier as a question.

Checklist: pump datasheet against the specification

  1. Confirm the revision of the data sheet and of the specification named in the enquiry.
  2. Check the liquid properties at the pumping temperature.
  3. Check rated flow and head in the same units as the customer's sheet.
  4. Check whether each pressure is gauge or absolute.
  5. Compare NPSH available with NPSH required and apply the customer's margin rule.
  6. Check where the rated point sits on the curve, and the minimum continuous flow.
  7. Check the materials class, each grade and any sour service requirement.
  8. Check the seal arrangement, the flush plan and the seal materials.
  9. Check the driver rating, enclosure and area classification.
  10. Check every test and its witness level against the inspection requirements.
  11. List blank fields and ask for them.

The general method is in the datasheet vs specification checklist.

How OdysseyGPT checks a pump datasheet

OdysseyGPT reads pump datasheets as documents: PDF, Word, Excel and CSV. Datasheet Comparison (beta) compares one baseline sheet with one or more others. Document Review checks a sheet against the requirements written in the specification.

  • What goes in: the baseline sheet, usually the customer's, and your sheet or several suppliers' sheets.
  • It matches fields that mean the same thing, even when they are named or placed differently.
  • It converts units before comparing where the conversion is exact, such as degrees Fahrenheit to Celsius.
  • Numeric tolerance rules can be applied, and formatting-only changes are set aside.
  • What comes out: one line per matched field for each sheet, every material difference and every field missing from one side.
  • Each value cites its cell or row, and the result exports as CSV or JSON for your deviation list.

The engineer decides which value stands and what to tell the customer or the supplier.

See three supplier pump sheets against one baseline

Send a customer data sheet and the supplier sheets you received for it. In the demo each supplier is compared with the baseline on its own, with differences and blanks listed.

Request a demo

See it on your own documents

Bring one pump item from a recent enquiry

Choose a sheet your engineers already know well. You will see what the comparison finds and can judge it against what they found by hand.

Request a demo

Frequently asked questions

What is a pump datasheet?

A pump datasheet is the agreed technical record for one pump. It lists the liquid, the operating conditions, the rated flow and head, the pump type, the materials, the seal, the driver and the tests. The buyer fills in the service and the maker fills in the selected pump. It forms part of the purchase order.

What is on a centrifugal pump data sheet?

A centrifugal pump data sheet covers the liquid properties, rated flow, suction and discharge pressure, differential head, NPSH available and required, efficiency and power, impeller diameters, casing design pressure, nozzle sizes and ratings, materials, mechanical seal and flush plan, bearings, driver, tests and weights.

Who fills in the pump data sheet, the buyer or the supplier?

Both. The buyer completes the operating conditions, the liquid, the site data and the requirements for materials, seals and testing. The supplier completes the performance, the construction details, the selected materials, the driver and the weights. Fields the buyer has fixed should come back unchanged, or be listed as deviations.

What is the difference between NPSH available and NPSH required?

NPSH available is the suction head the system provides at the pump inlet above the liquid's vapour pressure. NPSH required is what the selected pump needs at that flow to avoid cavitation damage. Available must exceed required, and many customers specify a minimum margin between the two. Both appear on the data sheet.

How do I compare two pump data sheets?

Put the customer's sheet and the supplier's sheet side by side and go field by field. Convert units first, check gauge against absolute pressure, and mark every different value, different material and blank field. Then decide which differences are deviations to declare and which are questions for the supplier.

References

API Standard 610, Centrifugal Pumps for Petroleum, Petrochemical and Natural Gas Industries

American Petroleum Institute

ASME B73.1, Specification for Horizontal End Suction Centrifugal Pumps for Chemical Process

American Society of Mechanical Engineers

ISO 5199, Technical specifications for centrifugal pumps, Class II

International Organization for Standardization

API Standard 682, Pumps: Shaft Sealing Systems for Centrifugal and Rotary Pumps

American Petroleum Institute