What a pump datasheet is
A pump datasheet, also written pump data sheet, is the agreed technical record for one pump or one group of identical pumps. The buyer states the service: what liquid, how much, from what pressure to what pressure. The maker answers with a selected pump and its curve. Once both sides sign it, the sheet sits in the order beside the specification.
Most sheets for process pumps follow the layout in a pump standard, so the fields appear in a familiar order. Catalogue sheets for small pumps are shorter, but they answer the same questions.
Compare the customer's pump sheet with yours
Bring the customer's pump data sheet and the sheet your supplier or your own team returned. We show you each field that differs, each blank and the cell both values came from.
Centrifugal pump data sheet, field by field
| Field | What it tells you | Check against the specification |
|---|---|---|
| Item number, service and quantity | Which pumps, and how many run and stand by | Tag, service and number of pumps match the requisition |
| Liquid | Name, pumping temperature, specific gravity, viscosity, vapour pressure, solids and corrosive content | Same values as the process data, at the same temperature |
| Capacity | Rated flow, with normal and minimum flow | Rated flow matches, in the same unit |
| Suction and discharge pressure | Pressures at the pump nozzles, rated and maximum | Gauge or absolute is stated and matches |
| Differential head | The head the pump must add at rated flow | Head matches, and any tolerance rule is met |
| NPSH available and required | Suction head the system gives and the pump needs | The margin between them meets the customer's rule |
| Pump type and size | Construction type, stages, nozzle sizes | The type is one the specification permits for the service |
| Performance | Efficiency, rated power, best efficiency point, minimum continuous flow, speed | Rated flow sits in the preferred region of the curve |
| Impeller | Rated, maximum and minimum diameter | Room to increase head if the specification asks for it |
| Casing design | Maximum allowable working pressure and temperature, hydrostatic test pressure | At least the specified design conditions |
| Nozzles | Size, flange rating, facing and position | Rating and facing match the piping class |
| Materials | Casing, impeller, shaft, wear rings, and the material class | Class and grades as specified, with any sour service requirement |
| Mechanical seal | Seal type, arrangement, materials and flush plan | Arrangement and plan as specified |
| Bearings and lubrication | Bearing type and how they are lubricated | Matches the specified system |
| Driver | Motor or turbine rating, speed, enclosure and area classification | Rating covers the power the specification requires |
| Inspection and testing | Performance, NPSH and hydrostatic tests, witnessed or observed | Each required test is listed with the right witness level |
| Weights and drawings | Pump, baseplate and driver weights, drawing numbers | Filled in before the order |
Which pump data sheet form applies
The form usually follows the standard the pump is bought to. The fields overlap, but the level of detail differs.
- API 610: centrifugal pumps for refinery, petrochemical and gas service. Its sheet is the most detailed, with materials classes and test requirements. See the API 610 pump datasheet review.
- ASME B73.1: horizontal end suction pumps for chemical process service, with standard dimensions.
- ISO 5199: technical requirements for centrifugal pumps in general process service.
- API 682: the shaft sealing system, which often has a seal data sheet of its own.
- Company forms: many buyers issue their own sheet based on one of the above. Use theirs, not yours.
Worked example: customer sheet against supplier sheet
The values below are made up. They show the kinds of result a line by line comparison gives, and why the same number in two units is not a difference while a blank is.
| Field | Customer sheet | Supplier sheet | Result |
|---|---|---|---|
| Pumping temperature | 149 °C | 300 °F | Same value after conversion |
| Differential head | 85 m | 85.0 m | Same value, formatting only |
| NPSH available / required | 4.5 m available | 4.2 m required | Margin of 0.3 m: compare with the customer's margin rule |
| Materials class | S-6 | S-5 | Different class: raise it |
| Seal flush plan | Plan 53B | Plan 11 | Different plan: raise it |
| Driver rating | Stated | Blank | Missing field: ask the supplier |
| Performance test | Witnessed | Not witnessed | Different witness level: raise it |
Four of the seven lines need a decision. Each belongs in the technical deviation list or goes back to the supplier as a question.
Checklist: pump datasheet against the specification
- Confirm the revision of the data sheet and of the specification named in the enquiry.
- Check the liquid properties at the pumping temperature.
- Check rated flow and head in the same units as the customer's sheet.
- Check whether each pressure is gauge or absolute.
- Compare NPSH available with NPSH required and apply the customer's margin rule.
- Check where the rated point sits on the curve, and the minimum continuous flow.
- Check the materials class, each grade and any sour service requirement.
- Check the seal arrangement, the flush plan and the seal materials.
- Check the driver rating, enclosure and area classification.
- Check every test and its witness level against the inspection requirements.
- List blank fields and ask for them.
The general method is in the datasheet vs specification checklist.
How OdysseyGPT checks a pump datasheet
OdysseyGPT reads pump datasheets as documents: PDF, Word, Excel and CSV. Datasheet Comparison (beta) compares one baseline sheet with one or more others. Document Review checks a sheet against the requirements written in the specification.
- What goes in: the baseline sheet, usually the customer's, and your sheet or several suppliers' sheets.
- It matches fields that mean the same thing, even when they are named or placed differently.
- It converts units before comparing where the conversion is exact, such as degrees Fahrenheit to Celsius.
- Numeric tolerance rules can be applied, and formatting-only changes are set aside.
- What comes out: one line per matched field for each sheet, every material difference and every field missing from one side.
- Each value cites its cell or row, and the result exports as CSV or JSON for your deviation list.
The engineer decides which value stands and what to tell the customer or the supplier.
See three supplier pump sheets against one baseline
Send a customer data sheet and the supplier sheets you received for it. In the demo each supplier is compared with the baseline on its own, with differences and blanks listed.
See it on your own documents
Bring one pump item from a recent enquiry
Choose a sheet your engineers already know well. You will see what the comparison finds and can judge it against what they found by hand.