What a heat exchanger data sheet contains
A heat exchanger data sheet is the one or two page summary that the buyer and the maker both work from. The buyer fills in the process side: the fluids, the flows, the temperatures and the pressure drop allowed. The maker fills in the design that meets it: the surface area, the tube count, the materials and the weights. When both halves are complete, the sheet becomes part of the order.
- Header: customer, plant, service, item number, size, type and how many shells are connected in series or parallel.
- Performance of one unit: fluid data for the shell side and the tube side, heat duty and temperature difference.
- Construction of one shell: design pressure and temperature, passes, corrosion allowance, tubes, baffles, nozzles and materials.
- Remarks: code requirements, testing, and any note that changes a field above.
Have your data sheet checked against the customer's
Bring the customer's heat exchanger data sheet and the one you returned. In the demo we compare them field by field and show each difference with the cell it came from.
Shell and tube heat exchanger datasheet, field by field
The table follows the order of a typical shell and tube sheet. Use the third column as your check when the customer's specification sits beside you.
| Field | What it tells you | Check against the specification |
|---|---|---|
| Service and item number | Which exchanger this is in the plant | Tag and service match the requisition |
| Size and type | Shell diameter, tube length and the three-letter TEMA type | The type is one the specification permits, for example a removable bundle |
| Fluid, flow and phase, each side | What flows through the shell and the tubes, and how much is liquid or vapour in and out | Same values and units as the customer's process data |
| Inlet and outlet temperatures | The temperature change required on each side | All four temperatures match, in the same unit |
| Operating pressure and pressure drop | Inlet pressure, and the drop allowed and calculated | Calculated drop is at or below the allowed drop on both sides |
| Fouling resistance | The allowance for deposits on each side | The values the customer gave, not the maker's defaults |
| Heat duty and corrected temperature difference | Heat exchanged and the driving temperature difference | Duty equals the customer's figure |
| Transfer rate and surface area | Service and clean heat transfer rates, and area per shell | Any surface margin the specification asks for is shown |
| Design pressure and temperature | The mechanical design conditions for each side, with test pressure | At least the specified values, including vacuum and minimum design metal temperature |
| Passes and corrosion allowance | Number of passes per shell and extra wall thickness | Corrosion allowance matches for each side |
| Tubes | Number, outside diameter, wall thickness, length, pitch and layout | Minimum diameter, wall and pitch rules in the specification are met |
| Baffles and impingement protection | Baffle type, cut and spacing, and protection at the inlet | Any required support or vibration rules are shown as met |
| Materials | Shell, channel, tubes, tubesheets, baffles and gaskets | Grade and any sour service or supplementary requirement |
| Nozzles | Size, rating and facing of each connection | Rating and facing match the piping class |
| Code and TEMA class | The pressure design code and the TEMA class | Code edition, class and any stamp the order requires |
| Weights | Empty, full of water and bundle weight | Filled in, so lifting and foundations can be checked |
TEMA data sheet type codes and tube layout
The TEMA data sheet describes construction with a three-letter type. The first letter is the front head, the second is the shell and the third is the rear head. An AES unit has a channel with a removable cover, a single-pass shell and a floating head. A BEM unit has a bonnet, a single-pass shell and a fixed tubesheet. TEMA also defines three classes, R, C and B, for different severities of service.
Tube layout is the pattern the tubes make in the tubesheet. The sheet shows it as an angle, with the pitch, which is the centre-to-centre distance between tubes.
- 30 degrees: triangular. It fits the most tubes into a shell.
- 60 degrees: rotated triangular.
- 90 degrees: square. It leaves straight lanes, so the outside of the tubes can be cleaned mechanically.
- 45 degrees: rotated square. It also leaves cleaning lanes.
If the customer's specification asks for mechanical cleaning on the shell side, a triangular layout on your sheet is a difference to raise.
Heat transfer coefficient, LMTD and NTU on the sheet
Three thermal terms explain most of the performance block.
- Heat transfer coefficient: how much heat passes through each unit of surface for each degree of temperature difference. The sheet gives an overall value for the clean exchanger and for the fouled, in-service exchanger.
- LMTD: the log mean temperature difference, an average of the temperature difference between the two fluids along the exchanger. The sheet usually shows it corrected for the flow arrangement.
- NTU: the number of transfer units, a measure of the thermal size of an exchanger. Designers use the NTU method when the outlet temperatures are not yet known, and the LMTD method when they are.
The three values are tied together: duty equals the overall coefficient multiplied by the area and the corrected temperature difference. If the numbers on a returned sheet do not multiply out, ask why before you accept it.
Plate and air cooled heat exchanger data sheets
A plate heat exchanger data sheet keeps the same process block but swaps the construction fields. It lists the plate material and thickness, the number of plates, the gasket material, the frame rating and the connection sizes. The main types of plate heat exchanger are gasketed plate and frame, brazed plate, welded plate and semi-welded plate, where pairs of plates are welded and the pairs are sealed with gaskets.
An air cooled heat exchanger data sheet adds the air side: design air temperature, face area, number of bays and bundles, fin type and material, fans, drivers and noise. Check the design air temperature and the noise requirement first, because they drive the size of the unit.
Checklist: heat exchanger data sheet against the specification
- Confirm you hold the latest revision of both the data sheet and the specification.
- Check every process value against the customer's sheet, in the same units.
- Check gauge against absolute pressure wherever a pressure is given.
- Compare fouling resistances and corrosion allowances side by side.
- Check design pressure, design temperature, vacuum and minimum design metal temperature.
- Check each material grade and any supplementary requirement.
- Check the TEMA type, the class and the tube layout against the cleaning requirements.
- Look for blank fields, and for notes in the remarks that change a field above.
- List every difference in your technical deviation list with a reason.
The general method is in the datasheet vs specification checklist.
How OdysseyGPT checks a heat exchanger data sheet
OdysseyGPT reads data sheets as documents: PDF, Word, Excel and CSV. Two tools do the checking. Datasheet Comparison (beta) compares the customer's sheet with yours, or with several suppliers' sheets. Document Review checks your sheet against the written specification.
- What goes in: a baseline data sheet, usually the customer's, and one or more sheets to compare with it.
- Fields are matched by meaning, so the two layouts can differ.
- Units are converted before comparing where the conversion is exact, and numeric tolerance rules can be applied.
- What comes out: one line per matched field, every material difference, and every field present on one sheet and missing from the other.
- Each value cites the cell or row it came from, and the result exports as CSV or JSON.
- For the specification check, each requirement gets a status with a quote from your sheet.
Your engineer decides which value is right and whether a difference becomes a deviation.
Watch a TEMA sheet compared in minutes
Send one exchanger: the customer's data sheet, your returned sheet and the specification. We show you the differences, the blank fields and the requirements each one touches.
See it on your own documents
Bring one exchanger from a live tender
Pick an item where the customer's sheet and yours are in different layouts or units. You will see every difference cited, and you decide which ones to declare.