OdysseyGPT

Guide

NDT report: what it must contain and how to check one

The fields every radiography, ultrasonic, magnetic particle and penetrant report needs, what each method adds, and how to check a set of reports against the weld map before the record book is closed.

By Ademola Afolabi, Founder, New Odyssey Ltd · Last reviewed:

The short answer

An NDT report is the signed record of one non-destructive test on a part or weld. It names the item, the method, the procedure, the acceptance standard, the result and the qualified person who signed. A customer accepts it only when the weld numbers match the weld map and every repair shows a re-test.

Key Takeaways

  • An NDT report (also called an NDE report) proves one test was done on one named item, to a named procedure, by a qualified person.
  • Most rejected reports fail on identity, not on the test: a weld number that is not on the weld map, or a procedure revision that was never approved.
  • A set of reports is only complete when every weld that needs testing has one, in the right method, and every repair has a re-test.
  • OdysseyGPT's NDE Coverage Review (beta) checks that set against the weld map and quotes each report.

What an NDT report is

This guide is written for manufacturers of engineered equipment: valves, pumps, pressure vessels, skids and fabricated steel. NDT means non-destructive testing. An NDT inspection looks for flaws in a weld, casting or forging without cutting or damaging it. NDE, non-destructive examination, is the same thing under the name the ASME codes use, so an NDE report and an NDT report are the same document.

The NDT report is the record of one test. It says what was tested, how, against which acceptance standard, what was found and who is accountable for the result. Your customer's inspector reads it to answer three questions. Was the right item tested? Was it tested the way the specification asked? Did a qualified person accept it?

One report rarely matters alone. An order can carry hundreds of welds, each needing one or more methods. The real job is proving that the whole set of reports covers every weld the specification names. The rules for what needs testing come from the customer's documents: see NDE requirements in equipment specifications.

Check a full set of NDT reports against the weld map

Bring one order's weld map and its RT, UT, MT and PT reports. We run the coverage check in front of you and show each weld with the report that covers it, or the gap.

Request a demo

NDT report format: the fields every report needs

There is no single NDT report format. Each test house and manufacturer has its own form. The fields below appear on almost all of them, because the codes and customer specifications ask for the same facts. You can copy this table as a review sheet.

NDT report fields, what each should say and what gets a report sent back
FieldWhat it should sayCommon reason for rejection
Report number and dateA unique number and the date of the testTest dated before the weld was finished or before heat treatment, when the specification asks for testing after it
Order and item identityPurchase order, project, tag or serial number, drawing number and revisionDrawing revision is older than the approved one
Weld or part identityThe weld number from the weld map, or the heat and piece number for a casting or forgingWeld number is not on the weld map, or two reports claim the same weld
Method and techniqueRT, UT, MT, PT or VT, and the technique usedMethod differs from the one the specification or ITP requires
ProcedureProcedure number and revisionProcedure revision was never approved by the customer
Acceptance standardThe code or specification the result was judged againstAcceptance standard is missing or is not the one in the order
ExtentHow much was tested: full length, a percentage, or named spotsExtent is lower than the specification requires
Equipment and materialsInstrument, probe, source, film, penetrant or particle type, with calibration referencesCalibration reference missing or out of date on the test day
Surface and stageSurface condition and the manufacturing stage, such as after final heat treatmentStage is not stated
ResultEach indication found, its size and location, and accepted or rejectedResult is given as a bare tick with no indication record
SignaturesName, qualification level and scheme of the technician and interpreter, and the customer's witness where requiredSigned at a level the customer does not accept for interpretation

What a radiography report adds, and the other methods

Each method records its own technique details. Without them, the reader cannot tell whether the test was able to find the flaws it was looking for.

Method-specific details on an NDT report
MethodWhat it findsDetails the report should record
Radiography (RT)Internal flaws such as porosity, slag and lack of fusionSource type, exposure technique, film or detector type, image quality indicator and the sensitivity reached, film density, and the location of each film along the weld
Ultrasonic (UT)Internal flaws, including planar flaws such as cracksInstrument, probe angle and frequency, calibration block, reference level, scanning sensitivity and couplant
Magnetic particle (MT)Surface and near-surface flaws in magnetic steelsMagnetising technique, current type, particle type, lighting and how the field strength was checked
Liquid penetrant (PT)Flaws open to the surface, on any non-porous materialPenetrant system and batch, surface temperature, dwell time and developing time
Visual (VT)Surface condition, profile and sizeLighting, gauges and aids used, and the stage of manufacture

MT and PT are the two surface methods. MT works only on magnetic materials, so austenitic stainless steel welds are usually tested with PT.

NDT Level 1, 2 and 3: who can sign the report

NDT staff are qualified to three levels under schemes such as ISO 9712 or ASNT SNT-TC-1A. The level on the report matters, because many customers only accept an interpretation signed at Level 2 or above.

  • Level 1 carries out the test under written instruction and records the readings.
  • Level 2 sets up the test, interprets the indications and judges them against the acceptance standard.
  • Level 3 writes and approves procedures and oversees the people and the work.

How to check a set of NDT reports against the weld map

  1. List every weld from the weld map, with its joint type and category.
  2. Against each weld, write the method and extent the specification and the ITP require.
  3. Find the report for each required method and confirm the weld number, drawing revision and procedure revision.
  4. Confirm the extent on the report meets the requirement.
  5. Confirm the result, the signature and the qualification level.
  6. For every rejected result, find the repair record and the re-test report for the same weld.
  7. Check the test instruments were in calibration on the test date. See calibration certificates for test reports.

A worked example. A vessel has 42 welds on its weld map. The specification asks for full radiography on the eight main seams and MT on all nozzle welds. The pack holds eight RT reports, but one names weld C4 twice and none names C5. One nozzle weld was rejected by MT and repaired, and the pack has no second MT report for it. Both gaps are paperwork gaps, and both would stop the record book at final review.

How OdysseyGPT checks NDT reports for you

NDE Coverage Review (beta) does the check above for the whole order. You upload the weld map and the RT, UT, MT and PT reports. You can add the ITP, the NDE procedure and the repair records.

  • One line per weld: the NDE required, the report found and whether it covers the weld.
  • Gaps sorted by type: missing report, short coverage, wrong method, repair not re-examined.
  • A quote from the requirement and from the report behind each finding, so you can open the page and confirm it.
  • A CSV or JSON export for your NDE log or the record book.

The tool reads the result and the interpreter's level as stated on each report. Your qualified NDE staff keep the judgement on every indication, and your engineers decide every finding.

See your own weld map checked line by line

Send a weld map and the NDT pack from a closed order before the call. You will see which welds are covered, which reports are missing and which repairs have no re-test, each with the quoted page.

Request a demo

See it on your own documents

Find the missing NDT report before your customer does

Pick an order that is close to final inspection. Bring its weld map and NDT reports to a demo and leave with a weld-by-weld coverage list you can act on.

Request a demo

Frequently asked questions

What is the meaning of NDT inspection?

NDT inspection means testing a part or weld for flaws without damaging it. NDT stands for non-destructive testing. Common methods are radiography, ultrasonic testing, magnetic particle testing, liquid penetrant testing and visual testing. The part stays usable after the test, which is why NDT is used on finished welds, castings and forgings.

What is MT and PT in NDT?

MT is magnetic particle testing and PT is liquid penetrant testing. Both find flaws at the surface. MT works on magnetic steels and can also find flaws just below the surface. PT works on any non-porous material, including stainless steel and aluminium, and finds flaws that are open to the surface.

What is NDT Level 1, 2, 3?

They are the three qualification levels for NDT staff under schemes such as ISO 9712 and ASNT SNT-TC-1A. Level 1 carries out tests under instruction. Level 2 sets up tests and interprets and judges the results. Level 3 writes procedures and oversees the work. Many customers require Level 2 or above to sign an interpretation.

Is an NDE report the same as an NDT report?

Yes. NDE means non-destructive examination and NDT means non-destructive testing. The ASME codes use NDE, and most European and ISO documents use NDT. The report holds the same facts either way: the item, the method, the procedure, the acceptance standard, the result and the signature of a qualified person.

Is there a standard NDT report format?

No single format is set for every job. The codes and the customer's specification say which facts must be recorded, and each test house lays them out on its own form. Check a form against the field table in this guide, and against the reporting section of the code your order names.

References

ISO 9712, Non-destructive testing: Qualification and certification of NDT personnel

International Organization for Standardization

Recommended Practice No. SNT-TC-1A, Personnel Qualification and Certification in Nondestructive Testing

American Society for Nondestructive Testing

ASME Boiler and Pressure Vessel Code, Section V, Nondestructive Examination

American Society of Mechanical Engineers

Related Pages