What an NDT report is
This guide is written for manufacturers of engineered equipment: valves, pumps, pressure vessels, skids and fabricated steel. NDT means non-destructive testing. An NDT inspection looks for flaws in a weld, casting or forging without cutting or damaging it. NDE, non-destructive examination, is the same thing under the name the ASME codes use, so an NDE report and an NDT report are the same document.
The NDT report is the record of one test. It says what was tested, how, against which acceptance standard, what was found and who is accountable for the result. Your customer's inspector reads it to answer three questions. Was the right item tested? Was it tested the way the specification asked? Did a qualified person accept it?
One report rarely matters alone. An order can carry hundreds of welds, each needing one or more methods. The real job is proving that the whole set of reports covers every weld the specification names. The rules for what needs testing come from the customer's documents: see NDE requirements in equipment specifications.
Check a full set of NDT reports against the weld map
Bring one order's weld map and its RT, UT, MT and PT reports. We run the coverage check in front of you and show each weld with the report that covers it, or the gap.
NDT report format: the fields every report needs
There is no single NDT report format. Each test house and manufacturer has its own form. The fields below appear on almost all of them, because the codes and customer specifications ask for the same facts. You can copy this table as a review sheet.
| Field | What it should say | Common reason for rejection |
|---|---|---|
| Report number and date | A unique number and the date of the test | Test dated before the weld was finished or before heat treatment, when the specification asks for testing after it |
| Order and item identity | Purchase order, project, tag or serial number, drawing number and revision | Drawing revision is older than the approved one |
| Weld or part identity | The weld number from the weld map, or the heat and piece number for a casting or forging | Weld number is not on the weld map, or two reports claim the same weld |
| Method and technique | RT, UT, MT, PT or VT, and the technique used | Method differs from the one the specification or ITP requires |
| Procedure | Procedure number and revision | Procedure revision was never approved by the customer |
| Acceptance standard | The code or specification the result was judged against | Acceptance standard is missing or is not the one in the order |
| Extent | How much was tested: full length, a percentage, or named spots | Extent is lower than the specification requires |
| Equipment and materials | Instrument, probe, source, film, penetrant or particle type, with calibration references | Calibration reference missing or out of date on the test day |
| Surface and stage | Surface condition and the manufacturing stage, such as after final heat treatment | Stage is not stated |
| Result | Each indication found, its size and location, and accepted or rejected | Result is given as a bare tick with no indication record |
| Signatures | Name, qualification level and scheme of the technician and interpreter, and the customer's witness where required | Signed at a level the customer does not accept for interpretation |
What a radiography report adds, and the other methods
Each method records its own technique details. Without them, the reader cannot tell whether the test was able to find the flaws it was looking for.
| Method | What it finds | Details the report should record |
|---|---|---|
| Radiography (RT) | Internal flaws such as porosity, slag and lack of fusion | Source type, exposure technique, film or detector type, image quality indicator and the sensitivity reached, film density, and the location of each film along the weld |
| Ultrasonic (UT) | Internal flaws, including planar flaws such as cracks | Instrument, probe angle and frequency, calibration block, reference level, scanning sensitivity and couplant |
| Magnetic particle (MT) | Surface and near-surface flaws in magnetic steels | Magnetising technique, current type, particle type, lighting and how the field strength was checked |
| Liquid penetrant (PT) | Flaws open to the surface, on any non-porous material | Penetrant system and batch, surface temperature, dwell time and developing time |
| Visual (VT) | Surface condition, profile and size | Lighting, gauges and aids used, and the stage of manufacture |
MT and PT are the two surface methods. MT works only on magnetic materials, so austenitic stainless steel welds are usually tested with PT.
NDT Level 1, 2 and 3: who can sign the report
NDT staff are qualified to three levels under schemes such as ISO 9712 or ASNT SNT-TC-1A. The level on the report matters, because many customers only accept an interpretation signed at Level 2 or above.
- Level 1 carries out the test under written instruction and records the readings.
- Level 2 sets up the test, interprets the indications and judges them against the acceptance standard.
- Level 3 writes and approves procedures and oversees the people and the work.
How to check a set of NDT reports against the weld map
- List every weld from the weld map, with its joint type and category.
- Against each weld, write the method and extent the specification and the ITP require.
- Find the report for each required method and confirm the weld number, drawing revision and procedure revision.
- Confirm the extent on the report meets the requirement.
- Confirm the result, the signature and the qualification level.
- For every rejected result, find the repair record and the re-test report for the same weld.
- Check the test instruments were in calibration on the test date. See calibration certificates for test reports.
A worked example. A vessel has 42 welds on its weld map. The specification asks for full radiography on the eight main seams and MT on all nozzle welds. The pack holds eight RT reports, but one names weld C4 twice and none names C5. One nozzle weld was rejected by MT and repaired, and the pack has no second MT report for it. Both gaps are paperwork gaps, and both would stop the record book at final review.
How OdysseyGPT checks NDT reports for you
NDE Coverage Review (beta) does the check above for the whole order. You upload the weld map and the RT, UT, MT and PT reports. You can add the ITP, the NDE procedure and the repair records.
- One line per weld: the NDE required, the report found and whether it covers the weld.
- Gaps sorted by type: missing report, short coverage, wrong method, repair not re-examined.
- A quote from the requirement and from the report behind each finding, so you can open the page and confirm it.
- A CSV or JSON export for your NDE log or the record book.
The tool reads the result and the interpreter's level as stated on each report. Your qualified NDE staff keep the judgement on every indication, and your engineers decide every finding.
See your own weld map checked line by line
Send a weld map and the NDT pack from a closed order before the call. You will see which welds are covered, which reports are missing and which repairs have no re-test, each with the quoted page.
See it on your own documents
Find the missing NDT report before your customer does
Pick an order that is close to final inspection. Bring its weld map and NDT reports to a demo and leave with a weld-by-weld coverage list you can act on.