EN 45545 Fire Protection

The European standard series for fire protection on railway vehicles. Part 2 sets requirements for the fire behaviour of materials and components, graded by three hazard levels.

Last reviewed by the OdysseyGPT team

What it is

EN 45545 is the European standard series for fire protection on railway vehicles. Part 2 sets requirements for the fire behaviour of materials and components. Each product is matched to a requirement set and tested for properties such as flame spread, heat release, smoke and toxicity, with limits graded by three hazard levels, HL1 to HL3.

Key Takeaways

  • The hazard level comes from the vehicle's operation category and design category, not from the component.
  • Each product is matched to a requirement set, which names the tests and limits.
  • A fire test report covers the material, thickness and build-up that was tested.
  • The 2020 edition, amended in 2023, added requirement sets. Check the edition on every report.

Why it matters

EN 45545, Railway applications: Fire protection on railway vehicles, is a European standard series in seven parts. Part 1 is general. It gives the definitions, the operation categories and the design categories, the fire safety objectives and the rules for evaluating conformity. Part 2 covers the fire behaviour of materials and components and is the part a component supplier meets most often. Part 3 covers fire resistance of fire barriers. The remaining parts deal with the design of the vehicle, electrical equipment, fire control and management systems, and installations for flammable liquids and gases. The idea behind Part 2 is simple to state. A vehicle is placed in an operation category according to the kind of route it runs on, for example how long it may spend in tunnels, and in a design category according to its type, for example a sleeping car or a double-deck vehicle. Together these give a hazard level, written HL1, HL2 or HL3. HL3 is the most demanding. Each product on the vehicle is then matched to a requirement set, written R followed by a number, according to what it is and where it is used: an interior wall lining, a seat, a floor covering, a cable, a printed circuit board. The requirement set names the tests and the limits for each hazard level. The properties tested include flame spread, heat release, smoke density and the toxicity of the smoke. The standard was revised in 2020 and amended in 2023, and that edition added requirement sets, so a test report made to the 2013 edition may not answer a current specification. For a supplier, the evidence is a test report for each non-metallic material or build-up, from a laboratory the customer accepts. A report belongs to the thing that was tested: the material, its thickness, its colour or coating where that matters, and the substrate it was bonded to. Customers often limit the age of reports and may ask for a summary list of every material with its mass, location, requirement set and report number. Use the edition your contract names for the tests and limits that apply.

How OdysseyGPT uses it

Document Review checks the fire clauses of a customer's specification against your material list, technical description and the text of your fire test reports. It quotes both sides for each finding, so a lower hazard level, an earlier edition or a missing report date is visible. OdysseyGPT reads documents only. It does not test materials, classify a product into a requirement set or judge whether a report covers a different thickness or build-up. An engineer decides that.

Evaluation questions

What does a rail tender usually ask for under EN 45545?

The hazard level, a list of all non-metallic materials with their requirement sets, and a test report for each from an accepted laboratory, often with a limit on the age of the report.

Frequently asked questions

What are HL1, HL2 and HL3?

The three hazard levels of EN 45545. They follow from the vehicle's operation category and design category. HL3 carries the strictest material requirements.

What is a requirement set in EN 45545-2?

A numbered group of tests and limits, written R1, R2 and so on, that applies to one kind of product in one kind of location. The supplier finds the set for each material and tests to it.

Do metal parts need EN 45545 fire test reports?

The testing is aimed at combustible materials. Bare metal is not normally tested. Coatings, adhesives, seals and insulation on a metal part may need evidence. Check the standard and the customer's specification for the exemptions and thresholds that apply.

References

EN 45545-1:2013 Railway applications. Fire protection on railway vehicles. Part 1: General

Estonian Centre for Standardisation and Accreditation (EVS)

Paid standard. Catalogue page used for the scope of Part 1 and the titles of Parts 2 and 3.

Visit source

EN 45545-2:2020+A1:2023 Railway applications. Fire protection on railway vehicles. Part 2: Requirements for fire behaviour of materials and components

Estonian Centre for Standardisation and Accreditation (EVS)

Paid standard. Catalogue page used for the edition and scope.

Visit source

Guide to EN 45545-2 fire testing requirements for railway materials

Measurlabs

Laboratory overview of hazard levels, requirement sets, the properties tested and what changed in the 2020 edition.